Loading...
Permit Mech 1957 Seminole 2012 (--- c� J ` CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD 0 ` ' " ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 -dJrt Application Number 12- 00000475 Date 4/24/12 Property Address 1957 SEMINOLE RD Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor BOYLE, JOSEPH F TROPIC HEATING & AIR 1957 SEMINOLE ROAD 750 MAYPORT RD ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241 -1788 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 103.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/21/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 103.00 103.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 107.00 107.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: / 95 7 .5 ,:r-o‘, off PERMIT # PROJECT VALUE $ Sd?2 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Systems: Total CFM g EEQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI l'f737b Air Conditioning: Unit Quantity / Tons Per Unit 1'. 5 REQUIRED Heat: Unit Quantity / BTU's Per Unit e,t,.,, Seer Rating /5.5 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets — Boilers BTU's El evators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ■o-e ! �• le- Phone Number Mechanical Company 1 a" Ace Office Phone, 24 Fax ?9'4 2 1) 2 a Co. Address: 7 '�`R C?....) City ( rL 1 C State 1'4 Zip 2 -- c,, \ ,� _ License Holder (Print): 'Prb \I k_. -S . ( n c State Certification/Registration # L ',CQ 3 Notarized Signature of License Holder A :11111 orn and subscribed efore me this G3 da of :� c. 20 I ' l M ' I Y c `�` , nature of Not Publi (J / re .t i *Ors. m dot - ftemissisa .1111 SON $ This combination qualifies for a Federal Energy ray as ail CERTIFIED,. Efficiency Tax Credit when placed in service V�/ WWW.ahridirectory.org between Feb 17, 2009 and Dec 31, 2011. Certificate of AHRI Certified Reference Number: 3647378 Date: 4/24/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 215BNA042 * * * *A Indoor Unit Model Number: FV4CN(B,F)005 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade /Brand name: LEGACY 15 PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 42000 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 15.50 Heating Capacity(Btuh) @ 47 F: 42000 Region IV HSPF Rating (Heating): 8.70 Heating Capacity(Btuh) @ 17 F: 25800 Ratings followed by an asterisk (`) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at y.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION - ; The information for the model cited on this certificate can be verified at 2 click on "Verify Cenifica!e" link and enter the AHRI Certified Reference Number and the date on r Air and Refrigeration Institute Air Heating, which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129797427246912020 C, t' 1n Right J® Mobile Report Job: Entire House Date: 4/23/2012 Ia•y limb -i Tropic Heating & Air Conditioning Inc. By: Bfent Reedy 750 Mayport Rd., Atlantic Beach, FL 32233 Phone 904- 241 -1788 Fax 9 04-241.2172 Email: Brenttr opicaceattnet Web: www.tropichealandac.com license: CACO52431 Pro'ect information For. Joe Boyle 1957 Seminole Rd., Atlantic Beach, FL 32233 Phone: 904 - 249 -5761 Email: Tropicac@msn.com Desi • n Conditions Location: Indoor: Jacksonville /Craig, FL, US Heating Cooling Elevation: 43 ft Indoor temperature ( °F) 70 75 Latitude: 30 °N Design TD ( °F) 35 16 Outdoor: Relative humidity ( %) 30 50 Heating Cooling Moisture difference (gr/Ib) 8.4 52.8 Drybulb( °F) 35 91 Infiltration: Dailyrange ( °F) - 17 ( M ) Method V1ittbulb( °F) 77 Simplified er Wind speed (mph) 15.0 7 5 Construction quality Average Fireplaces 0 ..G', i a' , � fk gr 4 °= ' x 0E1 1 f `i'7% 4'' ', ', `4A @ ,. ea y , x z gr ,. v,,, i, s x t a' Component Btu h/11 Btuh % of load Walls 3.4 6394 27.8 Doors Glazing 30.1 10084 43.9 VYlls 0 0 0 Ceilings 1.1 1439 6.3 Floors Infiltration 2.3 5067 22.0 Ceilrgs Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Gazirg Adjustments 0 Total 22984 100.0 Cooiin • Component BtuhAt Btuh % of load Walls 1.5 2864 10.1 Glazing 60.4 20250 71.2 Wails Interr Ir Cons Doors flitr0n 0 0 0 Ceti Ceilings 1.7 2196 7.7 ^� Floors 0 0 0 Infiltration 0.6 1241 4.4 Ducts 0 0 Ventilation 0 0 Internal gains 1890 6.6 Blower Adjustments 0 0 T / otal 28441 100.0 C3aary Latent Cooling Load = 3087 Btuh Overall U -value = 0.107 Btuh/f - °F Data entries checked. MI Rig ht-Su ite®Universa12012 12.0.04 Right J® Mobile 2012 -Apr- 2318:06.23 CIWINDOWSIT stmpW d268- 4760_bef4- d78042f37d1d.rup Calc = MJ8 Front Door faces: N Pagel Bryant Project Summary Job: -- Entire House Date: 4/23/2012 A E "il1p' , ' Tropic Heating & Air Conditioning Inc. By Brent Reedy Emig 750 Mayport Rd , Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax: 904 -241 -2172 Email: Brenttropicac@att.net Web: www.tropicbeatandac.00rn License: CACO52431 Project Information For: Joe Boyle 1957 Seminole Rd., Atlantic Beach, FL 32233 Phone: 904 - 249 -5761 Email: Tropicac @msn.com Notes: Desi • n Information Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db Inside db Inside db 7 °F °F Design TD 35 °F Design TD 16 °F Daily range 16 Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22984 Btuh Structure Ducts 0 Btuh Ducts 2844 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower ( ) 0 Btuh Piping 0 Btuh 0 Btuh Equipment load 22984 Btuh Use manufacturer's data Rate/swing multiplier 1.00y Infiltration Equipment sensible load 28441 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3087 Btuh Ducts 0 Btuh z Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft) 2000 2000 Equipment latent load 3087 Btuh Volume (ft3) 16000 16000 Air changes /hour 0.50 0.26 Equipment total load 31528 Btuh Equiv. AVF (cfm) 133 69 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref no. n/a Coil Efficiency AHRI ref no. n/a Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 1295 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �- wrigl7tsofr Rig ht-Su ite®Universal 2012 12.0.04 Right J® Mobile 2012- Apr - 2318:06:23 C 1WINDOWSIT twstmp -d268- 4760- bef4- d78042f37d1d Calc = MJ8 Front Door faces: N Page 1 Job: Date: 4!2312012 _ Right_Je W orksheet Date Reedy � .. Entire House Inc. e a ting & Air Conditioning ri�t.4�' ' � "'n`i Tropi H att net Web. vwawtropicheatandaacom License CACO524 .. 241 -1788 Fax 904-241 -2172 Email Brenttropicac@ First Floor phone 904 Entire House First ft 7 50 Mayport Rd.. Atlantic Beach, FL 32233 8.0 ft heatic0ol 280 0 ft Room name 8.0 ft 1.0 x 1100.0 1t Exposed wall 1100.0 ft' Room height 20000 ft' I I Room dimensions 8D Load Area (f t') (Btu h) Load Room area 1 HTM Area (f t') or perimeter (ft) U-value Or or perimeter (ft) (Btuh) I I T Construction (Btuhlft' - °F) (Btuhlft� ®® WpIS Cool number ® Cool Gross Cook Gross 0097 ne 3 1.50 480 408 1370 4228 240 204 685 307 6 ,zB obw o 2157 614 36 0 1079 2114 V y 0.870 ne 30.1 59.00 72 t--G 1D -c2om 0 87 3.36 1.50 640 545 1829 819 320 2 73 915 410 I ::: 12B -Obw 288 58 48 1 ) 1430 2941 1D -c2om 0.70 se 30.10 81.91 95 0 11 128 Obw 0.097 sw 3.36 1.50 480 408 1370 614 240 204 420 307 1 D - c2om 0.870 sw 30 61 72 0 2157 4437 36 0 1079 2 218 yy 126 - 0.097 nw 3. 1.50 640 5 43 1824 817 320 272 91 408 �-- G 1 ac2om 0 . 8 70 nw 30.10 59.00 97 0 2910 5703 48 0 1 91 2 2 21 8 C 16B -3oad 0.032 1 .11 1 .69 1300 1300 1439 219t 4� 11 I r � 82 F F or1 0.000 0 0.00 1300 1300 () () I I X 443 1 llhl 0 1 brysn Right -J® Worksheet Job: Entire House Date: 4/23/2012 N " t II Omi S By: Brent Reedy Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax: 904-241-2172 Email: Brent.tropicac@att . net Web: www.tropicheatandac.com License: CACO524... 1 Room name Entire House First Floor 2 Exposed wall 280.0 ft ht 140.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 10 x 1100.0 ft 5 Room area 2000.0 ft' 1100.0 ft' r r r Ty I Construction U -value Or ( HTM I Area (f N) Load Area (ft') Load number (Btuh /ft' - °F) (Btuh /ft') or perimeter (ft) (Btu h) I or perimeter (ft) (Btu h) Heat Cool I Gross I N/P /S Heat I Cool 1 Gross I N/P /S Heat I Cool 6 V�/ 12B -Obw 0.097 ne 3.36 1.50 480 408 1370 1 614 240 204 685 307 _{ 1D -c2om 0.870 ne 30.10 59.00 72 0 2157 4228 36 0 1079 2114 128-Obw 0.097 se 3.36 1.50 640 545 1829 819 320 273 915 410 1D -c2om 0.870 se 30.10 61.91 95 0 2860 5881 48 0 1430 2941 11 Vj/ 12B -Obw 0.097 sw 3.36 1.50 480 408 1370 614 240 204 685 307 L._. 1D -c2om 0.870 sw 30.10 61.91 72 0 2157 4437 36 0 1079 2218 W 12B -Obw 0.097 nw 3.36 1.50 640 543 1824 817 320 272 912 408 G, 10 -c2om 0.870 nw 30.10 59.00 97 0 2910 5703 48 0 1455 2852 C 16B -30ad 0.032 - 1.11 1.69 1300 1300 1439 2196 400 400 443 676 F FIor1 0.000 - 0.00 0.00 1300 1300 0 0 1100 1100 0 0 6 c) AED excursion r u Envelope loss/gain I I I 17917 25310 1 1 8682 1 12233 0 1 12 a) Infiltration 5067 1241 2533 621 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 1200 1200 Subtotal (lines 6 to 13) 22984 28441 11215 , 14743 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22984 28441 11215 14743 15 Duct loads 0% 0% 0 0 - 0% 0% 0 0 Total req uired ) ( room bad I I I 229840 1 28441 1295 I I ( 11215 0 1 14743 671 1 Air cfrn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w rightscs f[ 2012- Apr -23 18:06.23 Rig ht- Sude®U niversal 2012 12.0.04 Right J® Mobile Page 1 • Q\ WINDOWSITEMP \wstmp\a36e9b61 -d268- 4760- bef4- d78042f37d1d. rup CaIc = MJ8 Front Door faces: N Right -J® Worksheet Job: Job: 4/23/2012 1.- - Entire House By: Brent Reedy Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax: 904- 241 -2172 Email. Brent.tropicac@att.net Web: www.tropicheatandac.com License: CACO524 Second Floor 1 Room name 140.0 ft 2 Exposed wall 8.0 ft heat/cool Room height 1.0 x 900.0 ft 4 Room dimensions 800.0 ft' 5 Room area r r I 1 1 1 Load I A rea I Load U -value Or HTM Area (f t') Ty number or perimeter (ft) (Btuh) or perimeter number (Btuh /fN -`F) (Btuh/ft� Pe I Heat 1 Cool Gross i NIPIS Heat 1 Cool Gross 1 NIPIS Heat 1 Cool 0.097 ne 3.36 1.50 240 204 685 307 1D c2om 6 yy ---{' 12 -c2om 0.870 ne 30.10 59.00 0 1079 2114 L 2 V)I 128 -Obw 0.097 se 3.36 1.50 320 273 915 410 0 1430 2941 L_� 1D-c2om 0 870 se 30.10 61.91 48 11 Vyl 12B -Obw 0.097 sw 3.36 1.50 240 204 685 307 L_� 0.870 sw 30.10 61.91 36 0 1079 2218 1D -c2om 912 408 Vy B w 0. 097 nw 0. 1.00 320 272 L 0.87 nw 30.10 59.00 0 1455 2852 1 12 -0 6B -3Oa d 0.032 - 1.11 1.69 900 996 1521 C 16B -30a 900 0 F Flor1 0.000 - 0.00 0.00 200 200 0 6 I c) AED excursion I I 9235 13077 I 1 Envelope loss/gain 2533 621 12 a) Infiltration 0 p b) Room ventilation Occupants @ 230 0 0 13 Internal gains: P 0 Appliances/other Subtotal (lines 6 to 13) 11769 13698 0 0 Less external load 0 0 Less transfer 0 Redistribution 1176 0 0 13698 14 Subtotal -0% 0% 0 0 15 Duct loads r I Total room bad I I I 117690 1 13698624 1 I 1 1 1 Air required (cfm) Calculations approved by ACCAto meet all requirements of Manual J 8th Ed. 2012- Apr - 2318:06:23 w right snft Right -Su Re® U niv er sal 2012 12.0.04 Right JO Mobile Page C:\ WINDOWS \TEMPlwstmp\a36e9b61 -d268- 4760- bef4- d78042f37d1d.rup CaIc = MJ8 Front Door faces: N C omponent Constructions Job: b ry n n t Date: 4/23/2012 r Entire House By: Brent Reedy > a teems' imam Tropic Heating & Air Conditioning Inc. 750 Mayport Rd , Atlantic Beach, FL 32233 Phone 904- 241 -1788 Fax 904 -241 -2172 Email Brent tropicac@att .net Web: www.tropicheatandac.com License: CACO52431 Pro'ect Information For: Joe Boyle 1957 Seminole Rd., Atlantic Beach, FL 32233 Phone: 904- 249 -5761 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (grub) 8.4 52.8 Dry bul b ( °F) 35 91 Infiltration: Dailyrange ( °F) - 17 ( ) Method Simplified \f tbulb( °F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain ft BM/fr - °F fE- °F/Bluh 13tuhlfr Btuh Btuh/ft Btuh Walls 12B -Obw: Frm wall, brk 4" ext, r -11 cav ins, 1/2" gypsum board int ne 408 0.097 11.0 3.36 1370 1.50 614 fnsh, 2 "x4" wood frm se 545 0.097 11.0 3.36 1829 1.50 819 sw 408 0.097 11.0 3.36 1370 1.50 614 nw 543 0.097 11.0 3.36 1824 1.50 817 all 1905 0.097 11.0 3.36 6394 1.50 2864 Partitions (none) Windows 1D -c2om: 2 glazing, clr outr, air gas, mtl no brk frm mat, clr innr, 1/4" ne 72 0.870 0 30.1 2157 59.0 4228 gap, 1/8" thk se 95 0.870 0 30.1 2860 61.9 5881 sw 72 0.870 0 30.1 2157 61.9 4437 nw 97 0.870 0 30.1 2910 59.0 5703 all 335 0.870 0 30.1 10084 60.4 20250 Doors (none) Ceilings 16B -30ad: Attic ceiling, asphalt shingles roof mat, r -30 ceil ins, 1/2" 1300 0.032 30.0 1.11 1439 1.69 2196 gypsum board int fnsh Floors FIor1: FIor1 1300 0 0 0 0 0 0 4 wrightsoft 2012- Apr -23 18 06:23 9 Right -Su de ®Univer sal 201212.0.04 Right J® Mobile Pagel C \ WINDOWSITEMP \wstmp\a36e9b61 -d268- 4780- bef4- d78042f3 Calc = MJ8 Front Door faces: N