Permit Mech Commission chambers 2012 'ra - j-L`!J' l�, 4 t" CITY OF ATLANTIC BEACH Ai , 800 SEMINOLE ROAD J w , ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000479 Date 4/27/12 Property Address 850 SEMINOLE RD Application type description MECHANICAL HVAC ONLY Property Zoning RES SF DISTRICT Application valuation . . . 0 Application desc CU AHU /COMMISIION CHAMBERS Owner Contractor CITY OF ATLANTIC BEACH B & G REFRIGERATION 800 SEMINOLE RD 3230 KLINE RD. ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32246 (904) 620 -0081 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 159.00 Plan Check Fee . . .00 Issue Date . . . 4/25/12 Valuation . . . . 0 Expiration Date . 10/22/12 Other Fees STATE MECH DCA SURCHARGE 2.39 STATE MECH DBPR SURCHARGE 2.39 Fee summary Charged Paid Credited Due Permit Fee Total 159.00 159.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.78 4.78 .00 .00 Grand Total 163.78 163.78 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247-5845 JOB ADDRESS: .:1\--\.\ C` s ' \ \O \ SS\c, m 9 rr ,` PERMIT # PROJECT VALUE $ 1ag3. CAD NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit . Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # 4y?)\ Air Conditioning: Unit Quantity ca Tons Per Unit 1 4 REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating \ $ Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. 1 hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name "\ a - \O ,A-L4c >..c_. QQ-6(l Phone Number C101,4 `1 • RR Mechanical Company P- C. Q P,c- e1tyfQ.� c c- l 0 \ C\C- Office Phone ( . D081 Fax 9U \ $lS Co. Address:t ', ?i /-4 i�1D, `Za J City \OJi State �`-1 Zip .. S . NaULp License Holder (Print): (1,\ J , ` 4. �! �* -ems.. State Certification/Registration # C CI5 - a97l c ) _Tc r r' - , co Notarized Signature of License Holder h,,. / / ., p n 4 I . )i %416.11W16.1dIfOrn and subscribed be 'ore me day of 4/ 201)- 1 / � o.P , ,, STEPHANE STRAHAN I = � � Notary Public State of Floriols�� nature of Notary Public / i/' 1 ,, � a , My Comm. Expires Apr 12, 2015 4 ' ;4; � es Commission N EE 72055 0 Arita 1 1-1011 This combination qualifies for a Federal Energy as ad CERTIFIED TM Efficiency Tax Credit when placed in service www.ahridirectory.orq between Feb 17, 2009 and Dec 31, 2011. Certificate of Product Ratings AHRI Certified Reference Number: 4431330 Date: 4/25/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: DSZC180601B* Indoor Unit Model Number: AVPTC426014A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 56000 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 17.00 Heating Capacity(Btuh) @ 47 F: 56000 Region IV HSPF Rating (Heating): 9.45 Heating Capacity(Btuh) @ 17 F: 34600 " Ratings followed by an asterisk ( ") indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified atwww.ahridirectory.org, Air- Conditioning, Heating, click on `Verify Certificate" link and enter the AHRI Certified Reference Number and the date on .■ a ' which the certificate was issued, which is listed above, and the Certificate No., which is listed below. and Refrigeration Institute ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129798351603434103 COMMERCIAL LOAD CALCULATIONS Manual N Air Conditioning Contractors of America For: Name City Commision Phone Address 850 Seminole Rd. City Atlantic Beach State & Zip FL By: Contractor Energy Design Systems, Inc. Phone (904)268 -3670 Address 12132 Weatherwood Estates Dr. W. City Jacksonville State & Zip FL, 32223 COOLING LOAD 1. DESIGN CONDITIONS Time of Day 3 PM Dly Range 19 Latitude 30 a.Inside db 72 RH 50 b.Outside db 94 wb 77 Grains 49 Otsid db @ 3pm 94 - TOD corr - inside db 72 Equals 22 T.D. Daily Range Factor= M 2. SOLAR RADIATION HEAT GAIN THROUGH GLASS COOLING LOAD Exposure Shading / NOTES Sq. Ft. SolrFactr GlasFactr Sensible N 100 X 19 X 0.7 = 1330 NE 65 X 38 X 0.7 = 1729 E 100 X 56 X 0.7 = 3920 SE 65 X 57 X 0.7 = 2594 S 100 X 48 X 0.7 = 3360 SW 65 X 88 X 0.7 = 4004 W 100 X 81 X 0.7 = 5670 NW 50 X 39 X 0.7 = 1365 3. TRANSMISSION GAINS Equiv or Exposure db Sq. Ft. U Factor Temp Diff Glass 645 X 0.8 X 22 = 11352 N 180 X 0.09 X 22 = 356 NE 130 X 0.09 X 26 = 304 E 180 X 0.09 X 31 = 502 Walls SE 130 X 0.09 X 33 = 386 S 180 X 0.09 X 41 = 664 SW 130 X 0.09 X 47 = 550 W 180 X 0.09 X 43 = 697 NW 130 X 0.09 X 28 = 328 Doors X 0.58 X 18 = Partition X 0.05 X 22 = RA Cing X 0.09 X 22 = Roof/Clng 1222 X 0.05 X 57 = 3483 Floors 112 X X 22 = X X = Use Table 9a to Determine the Temp. Dif. Across an RA Ceiling PAGE TWO 4. INTERNAL HEAT GAIN Latent a. OCCUPANTS Number Sensible Latent 30 X 230 = 6900 X _ 30 X 170 5100 X = b. Lights & Others NOTE:Use 60%% of installed watts for lights in RETURN AIR CEILING Watts Incandescnt X 3.4 = Flourescent 1500 X 4.1 = 6150 HP Motors Btuh Usg Ftr X= X= Appliances Other 5. INFILTRATION Ft3 /Min db Temp Dif 10 X 22X 1.1= 242 Grains Diff 10 X 49X 0.68 = 333 6. SUBTOTALS LOADS & SPACE LOADS 55885 5433 7. DUCT HEAT GAIN Gain Line 6 Factor Sensible 0.1 X 55885 = 8. ROOM, SPACE OR DESIGN LOAD Add Duct gain (7) to Subtotal (6) 55885 9. VENTILATION Ft3 /Min db Temp Dif 600 X 22 X 1.1 = 14520 Grains Diff 600 X 49 X 0.68 = 19992 PAGE THREE 10. RETURN AIR LOAD FROM LIGHTING AND ROOF NOTE: Use 40% of watts for lights recessed in a return air ceiling Incandescent X 3.4 = Flourescent X 4.1 = NOTE: Use 100% fo the roof load for return air ceilings (Roof Load) Sq. Ft. U Factor ETD* X 0.09X = *(ETD correction based on plenum temp.) 11. TOTAL SENSIBLE LOAD ON EQUIPMENT (Btuh) = 70405 TOTAL LATENT LOAD ON EQUIPMENT (Btuh) 25425 12. TOTAL COOLING LOAD ON EQUIPMENT (Btuh) 1 95831 1 (Tons) 7.99 PAGE FOUR HEATING LOAD 13. DESIGN LOADS Inside db Outside db b Difference 72 32 = 40 14. TRANSMISSION LOSSES HEATING LOAD db Exp. Sq. Ft. Factor Temp Diff Heating Load Windows 955 x 1.13 x 40 = 43166 x x = 180 x 0.09 x 40 = 648 Walls 180 x 0.09 x 40 = 130 x 0.09 x 648 40 = 4 468 180 x 0.09 x 40 = 648 130 x 0.09 x 40 = 468 Roof/ 1222 x 0.05 _ Ceiling x 0.05 x 40 2444 x x — Floor 112 x 0.81 x 40 3629 — 3629 x x = x x = 15. INFILTRATION db Ft3 /Min Temp Diff 15 X 40 X 1.1 = 660 16. SUBTOTAL HEATING LOAD FOR SPACE 52779 17. DUCT HEATING LOSS Loss Line 14 Factor Subtotal 0.15 X 52119 = 7818 18. VENTILATION db Ft3 /Min Temp Diff 600 X 40 X 1.1 = 26400 19. HUMIDIFICATION LOAD Inside RH Desired Max ( ) Ft3 /Min Btu /Hr / 100 X _ (water) (air) gal /day Ft3 /Min X / 100 = 20. TOTAL HEATING LOAD ON EQUIPMENT (Btuh) I 86997 I (Tons) 7.25 Energy Design Systems, Inc. 12132 Weatherwood Estates Dr. W. Jacksonville, FL 32223 (904) 268 -3670