Loading...
Permit Mech 349 Plaza 2012 : 11 CITY OF ATLANTIC BEACH ) 800 SEMINOLE ROAD U =� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 13 Application Number 12- 00000514 Date 5/01/12 Property Address 349 PLAZA Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor DELOACH GENEVIEVE M & JUANITA HUXHAM HEATING & AIR C/O GENEVIEVER DELOACH 2101 FLORIDA BLVD. 349 PLAZA NEPTUNE BEACH FL 32266 ATLANTIC BEACH FL 322335441 (904) 246 -6721 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 99.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/28/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 B ADDRESS: 3' 1 PERMIT # / ' q Jo � � � Z PROJECT VALUE $ S 00 c ' ARI # V6570, REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity t Tons Per Unit .. Heat: Unit Quantity / BTU's Per Unit Seer Rating 1 S Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Oci / A.c�✓� cJ't Phone Number Mechanical Company LAW /t ) Rr/._ , - 1. (._. Office Phone `g`(6 -f 77/ Fax ,y‘, , o31 - 7 Co. Address: icr)1 F /©e%aA �h- ) / City Y().6 State 7% Zip3a��� License Holder (Print): `I (/44 5 �l ; /w67 State Certification/Registration # C LAC-o 5 ?BI S Notarized Signature of License Ho�ea� / — Sw • and subscribed be ••re - this Al day 20 r 3 r r IP L, ;' u a e of Notary Pu 9 .: ►i� r e�aCIhnei ION td ti >k , M iEi 4b+l1ls 14, 2014 NM y ����� a M tey pubNc UMeiw hers �j�^+�! - Project Summary r ject Sury Job: Apr 30, R��I��V1.J�L � •� Date: Apr 30, 2012 energy consulting Entire House By: Erin Rodriguez Project Information For: Deloach 349 Plaza, Atlantic Beach, FL 32233 Notes: Huxham - a/c install Desi. n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 76 °F Design TD 29 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 56 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 15213 Btuh Structure 18019 Btuh Ducts 4640 Btuh Ducts 6341 Btuh Central vent (31 cfm) 1000 Btuh Central vent (31 cfm) 552 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment Toad 20853 Btuh Use manufacturer's data n Rate /swing multiplier 0.97 Infiltration Equipment sensible load 24165 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1992 Btuh Ducts 1601 Btuh Heating Cooling Central vent (31 cfm) 1194 Btuh Area (ft') 1568 1568 Equipment latent load 4787 Btuh Volume (ft') 12544 12544 Air changes /hour 0.38 0.20 Equipment total Toad 28952 Btuh Equiv. AVF (cfm) 79 42 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make TRANE Make TRANE Trade Trade Model 4TWR5036 Cond 4TWR5036 ARI ref no. Coil GAM5A0B42 ARI ref no. Efficiency 8 HSPF Efficiency 15 EER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47 °F Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 981 cfm Actual air flow 981 cfm Air flow factor 0.049 cfm /Btuh Air flow factor 0.040 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. - wrigIitsoft Right- Suite® Universal 7.1.09 RSU01508 2012 - May -01 10:06:32 ACCA C:\ Users \erin \Documents \Wrightsoft HVAC \Template \Deloach- Huxham.rup Calc = MJ8 Orientation = N Page 1 This combination qualifies for a Federal Energy u. C E RT 1 F I E D TM Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2011. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4657247 Date: 5/1/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 4TWR5036G1 Indoor Unit Model Number: GAM5A0C42M31 Manufacturer: TRANE Trade /Brand name: XR15 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 37400 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 33000 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 20800 Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION At IliD, The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air - Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on A. - ' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129803458540315600