Loading...
Permit Mech 5616 Fleet Landing 2012 14' . ; i : � CITY OF ATLANTIC BEACH r j 800 SEMINOLE ROAD 0 ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000521 Date 5/02/12 Property Address 1 FLEET LANDING BLVD MAIN Tenant nbr, name UNIT 5616 Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC FLEET LANDING 6491 POWERS AVENUE 1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 32233 (904) 724 -7211 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 99.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 10/29/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 L ( Ph (904) 247-5826 Fax (904) 247 -5845 T JOB ADDRESS: 2 [(CI Ca 11 i 1 e"1 6 r V �. 1 �G N 4 ? c !� �'ac�, $ HERMIT # Url 1 ')' ► - 5G I ‘ 5'2 PROJECT VALUE $ 3 , Soo ... 0 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION RI Air Conditioning: Unit Quantity ' Tons Per nit (3 R QUIRE 3 U Heat: Unit Quantity 1- BTU's Per Unit 7< G o - Seer Rating / - Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: \J vi'l 1" 6G 1c, Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. 1 hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. N Property Owners Name t lee 1 Lc n d i in Phone Number ) f Go —WOO nn rr n Mechanical Company �I.IG `! , -6 f ea'f) ,, 1� 1 ✓ Office Phone Zy —nr, Fax 7Z ( 5 Co. Address: CvY? ( �c 4 e City Tc,c I (I e State ft..Zip 3z. 2 rz v License HQ ►11 IIUI t 4,4 ( "W �- T C e,� State i ication/Registration # CN-C �q-/ Notarize $ i df f • se Holder 7 .—�. : ti►Y Comm Expir ; Janua 10, 2014 • = Sworn and subscribed before me his i� day of 1 20 I Z N a, "- A * S Est ; Q S ignature of Notary Public ti 4 Right Report Job: Date: 5/2/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904 - 724 -5925 Email: operez @davidgrayonline.com Pro'ect Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 5616, Atlantic Beach, FL 32233 Email: operez @davidgrayonline.com Desi • n Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Dailyrange ( °F) - 17 (M ) Method Simplified Wet bulb - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin • Component Btuh/ft Btuh % of load Walls 3.4 3989 16.7 Wil Irilltrdim Glazing 43.9 5712 23.9 Doors 13.5 425 1.8 Ceilings 2.8 3784 15.9 Floors 4.8 6493 27.2 1 Infiltration 2.6 3463 14.5 Ron 0 0 Gazing Piping 0 0.:. Humidification 0 0 OtEr Ventilation 0 0 Celirgs Adjustments 0 Total 23865 100.0 Coolin • Component Btuh/ft Btuh % of load Walls 1.5 1787 7.4 W EII Irterel C iris Glazing 67.9 8831 36.7 IrflltrAiai Doors 11.4 360 1.5 Flags Ceilings 5.9 7961 33.1 Floors 1.8 2402 10.0 Infiltration 0.6 834 3.5 aaa • . `a Ducts 0 0 Ventilation 0 0 Internal gains 1890 7.9 B 0 0 ra „,'� Cglirx3s Adjustments 0 Other Total 24065 100.0 Latent Cooling Load = 2270 Btuh Overall U -value = 0.146 Btuh /ft - °F Data entries checked. w�i hts+tyft' 2012- May -02 06:19:28 ,... 9 Right- Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 ACCX C: \WINDOWS\ TEMP\ wstmp\ 2206b9c9- c01a- 412f- b264- 65ccb7e7a41d.rup CaIc = MJ8 Front Door faces: N Ilk Project Summary Date: W i htso Date: 512/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904 - 724 -5925 Email: operez@davidgrayonline.com Project Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 5616, Atlantic Beach, FL 32233 Email: operez @davidgrayonline.com Notes: Desi • n Information Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 ° F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 °Ao Moisture difference 53 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23865 Btuh Structure 24065 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23865 Btuh Use manufacturer's data y Rate /swing multiplier 1.00 Infiltration Equipment sensible load 24065 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2270 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft) 1350 1350 Equipment latent load 2270 Btuh Volume (ft 12150 12150 Air changes /hour 0.45 0.23 Equipment total load 26335 Btuh Equiv. AVF (cfm) 91 47 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Trade Model Cond AHRI ref no. Coil AHRI ref no. Efficiency 0 HSPF Efficiency 13 SEER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47 °F Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1096 cfm Actual air flow 1096 cfm Air flow factor 0.046 cfm /Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W i '1 hl is _ _ 2012- May -02 06:19:28 t g Right-Suite® niversal 2012 12.0.04 Right J® Mobile Pa 9 e 1 C:\ WINDOWS\ TEMP\ wstmp\ 2206b9c9- c01a- 412f- b264- 65ccb7e7a41d.rup CaIc = MJ8 Front Door faces: N 41 wrightsoft Right -J® Worksheet Job: Entire House Date: 5/2/2012 By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904 - 724 -5925 Email: operez @davidgrayonline.com 1 Room name Entire House First Floor 2 Exposed wall 150.0 ft 150.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 30.0 x 45.0 ft 5 Room area 1350.0 ft' 1350.0 ft' t 1 1 Ty Construction U -value Or I HTM Area (ft') Load I Area (ft') Load number number (Btuh /ft' - ° F) (Btuh /ft') 1 or perimeter (ft) 1 (Btuh) or perimeter (ft) (Btuh) I 1 Heat Cool Gross I N /P /S I Heat I Cool Gross I N /P /S Heat I Cool 6 Vp/ 12B -Obw 0.097 n 3.36 1.50 405 375 1259 564 405 375 1259 564 C 1A -c1om 1.270 n 43.94 36.26 30 0 1318 1088 30 0 1318 1088 V 12B -Obw 0.097 e 3.36 1.50 270 199 666 298 270 199 666 298 G 1A -clom 1.270 e 43.94 92.64 40 0 1758 3706 40 0 1758 3706 11 I D 11D0 0.390 e 13.49 11.43 32 32 425 360 32 32 425 360 1// 12B -Obw 0.097 s 3.36 1.50 405 375 1259 564 405 375 1259 564 C 1A -clom 1.270 s 43.94 41.95 30 0 1318 1258 30 0 1318 1258 W 126-Obw 0.097 w 3.36 1.50 270 240 805 361 270 240 805 361 I G 1A -clom 1.270 w 43.94 92.64 30 0 1318 2779 30 0 1318 2779 C 16A -11a1 0.081 - 2.80 5.90 1350 1350 3784 7961 1350 1350 3784 7961 F 20P -5t 0.139 - 4.81 1.78 1350 1350 6493 2402 1350 1350 6493 2402 6 I c) AED excursion 0 0 I Envelope loss /gain 20403 21341 20403 21341 12 a) Infiltration 3463 834 3463 834 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances /other 1200 1200 Subtotal (lines 6 to 13) 23865 24065 23865 24065 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23865 24065 23865 24065 15 Duct loads 0% 0% 0 0 - % o% 0 0 I 1 Total require room d ( load cfm) 1 1 238651 240651 1 23865 1 24065 I Air 1096 1096 1096 1096 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WT l htsC?ft 2012 - May - 0206:19:28 Right - Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 C: \WINDOWS\ TEMP\ wstmp\ 2206b9c9- c01a- 412f- b264- 65ccb7e7a41d.rup CaIc = MJ8 Front Door faces: N Component Constructions Job - rl� ric�hts�►ft" p Date: 5/2/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904 - 724 -5925 Email: operez@davidgrayonline.com Pro'ect Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 5616, Atlantic Beach, FL 32233 Email: operez @davidgrayonline.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) Method Simplified Wet bulb ( °F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Insui R Htg HTM Loss Clg HTM Gain ft' Btuh/ft' - °F ft'- °F /Btuh Btuh /ft. Btuh Btuh /ft. Btuh Walls 12B -Obw: Frm wall, brk 4" ext, r -11 cav ins, 1/2" gypsum board int n 375 0.097 11.0 3.36 1259 1.50 564 fnsh, 2 "x4" wood frm e 199 0.097 11.0 3.36 666 1.50 298 s 375 0.097 11.0 3.36 1259 1.50 564 w 240 0.097 11.0 3.36 805 1.50 361 all 1189 0.097 11.0 3.36 3989 1.50 1787 Partitions (none) Windows 1A -c1 om: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk n 30 1.270 0 43.9 1318 36.3 1088 e 40 1.270 0 43.9 1758 92.6 3706 s 30 1.270 0 43.9 1318 41.9 1258 w 30 1.270 0 43.9 1318 92.6 2779 all 130 1.270 0 43.9 5712 67.9 8831 Doors 11 DO: Door, wd sc type e 32 0.390 0 13.5 425 11.4 360 Ceilings 16A-11 al: Attic ceiling, asphalt shingles roof mat, r -11 cell ins, 1/2" 1350 0.081 11.0 2.80 3784 5.90 7961 gypsum board int fnsh Floors 20P -5t: Fir floor, wd flr, 1" thkns, tile flr fnsh, r -5 ext ins, amb ovr 1350 0.139 5.0 4.81 6493 1.78 2402 2012 - May -02 06:19:29 ."_ wrlghtsoft" Rig ht-Su ite® Universal 2012 12.0.04 Right J® Mobile Page 1 AC C: \WINDOWS\ TEMP\ wstmp\ 2206b9c9- c01a- 412f- b264- 65ccb7e7a41d.rup Calc = MJ8 Front Door faces: N AED Assessment Jab. �-�� Date: 5/2/2012 III ��� Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 - 724 -7211 Fax: 904 - 724 -5925 Email: operez@davidgrayonline.com Project Information For: Fleet Landing, David Gray Heating & Air, Inc. 1 Fleet Landing Blvd. # 5616, Atlantic Beach, FL 32233 Email: operez @davidgrayonline.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Drybulb( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) V\bt bulb (°F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 12,o00- 11,000- 10,000— 8000 - 7,000- 6,000- 5,000- 4,000- 3,000- 2, 1,000- 0 I I I I I I I I I I I I 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / Houly Average z PEDlimit Maximum hourly glazing load exceeds average by 15.7 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh 2012- May -02 06:19:29 Wri htSa R ight - Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 Ai 14, CaIc = MJ8 Front Door faces: N A CERTIFIED TM www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4261913 Date: 5/2/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: GSZ130361 B* Indoor Unit Model Number: AR *F363616C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 35000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 33600 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 20800 Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION Loo' The information for the model cited on this certificate can be verified at www.ahridirector Air- Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on .. - and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129804432191343323 i