Permit Mech 1830 Ocean Grove Dr 2012 S%' �1 Il � r v� e r r ` ?' CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ,,,,, v , - - A , ,,,":1,' , , ATLANTIC BEACH, FL 32233 �� �� � INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000525 Property Address Date 5/03/12 1830 OCEAN GROVE DR Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 CU 1 AHU Owner Contractor SHOWALTER, RUSSELL H. OCEAN STATE HEAT & AIR, INC. 32 SARAGOSSA STRD. N. 1476 ATLANTIC BLVD. ST.AUGUSTINE FL 320843569 NEPTUNE BEACH FL 32266 (904) 249 -8251 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 91.00 Plan Check Fee .00 Issue Date Valuation . . 0 Expiration Date . . 10/30/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 91.00 91.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 95.00 95.00 .00 .00 PERMIT 1S APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL. 32233 ? q Ph (904) 247 -5826 Fax (904) 247 -5845 ..,, ::: 3[:- .) JOB ADDRESS: / & 3 O C'') c- c.e�!-t G,..nnv.c... Dom" .e: PER>4�I' �- PROJECT VALUE S 3 y /2 . o© NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity _ Tons Per Unit Heat: Unit uantitt U . s BTU Per Unit Seer Rating Duct Systems: Total CFM REC LURED REPLACEMENT AIR CON 3IT'IONTNG & HEATING SX'STENI INSTALLATION Air Conditioning: Unit Quantity ( Tons Per Unit 2 ART 3 $° wY ' Heat: Unit Quantity — ���� E� Q / BTU's Per Unit S' l�+✓ Seer Rating l 3. S Duct Systems: Total CFM R£(;RE3 FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value _ (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial. Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators AT ,E OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certth'that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name to r (( Z Lb c,,,,.)0,,,14 -.c, Phone Number 7/F— G t 0 ,- 3 \)1,3 g e c h a n i c a l - Company S f e - d { ti-c.02-1(2114j < 1 . 4 4 4 ) . 4 4 4 , - Office Phone 2Y 9- 1 Fax 2,q s'— 85'v9 Co. Address: Of 7 G A-Ktt,,Jr`c, a lv d City Nyolv t. 4 State Ft Zip 3 zz33 License Holder (Print): _ 6-i . � � � . 1 . State Certi is tionfRegistration # CA-co 0 Notarized Signature of License Holder WErl E P. MORALES Sworn ant su ribeo befor- sa . 214. day of 201 ,.47, Comm# DD0860534 at� ' �; ; ,� Signature � Notary Pu is ,�,� , Expires 3/2/2013 % ,„2, ` � Florida Notary Assn., Inc , vii io.3V rnx 90 42495949 OCEAN_STATE_A /C 4 ATLANTIC -BEACH IZI 002/003 ACCA Manual "J" Heat Load Calculation Date 05/02J12 Customers Name Showalter Location Atlantic Beech Type of Construction Heat Transfer Multipliers Area or Exposure Notes HEATING COOLING f3Tt1H Length HEATING COOLING 1 Gross Wall 1 080 2,3 Windows North A I N 2 29.0 ; w East &West Al �'�1�8:0 "1� ': ; 377 ; , 208 2 29.0 : , ,,,, E W ; 1. , ,,�'4 ,154. 2407 , South Al 5 2 29.0 ii „„ .. ?rs;;; 10 290 3.50 4 Doors 2sr0 .. Front Solid Wood - Panel 27.0 li ? ',' f'Pb:' ; >' ,, 20 , , , ' Patio Solid Wood 540 17 5 Pal - Storm 16,4 i ,`''l 18 , Other g S, 2 295 175' �_ SId GI Dr, 32.6 ' , :' - 'E�25� iii`f','`iji: 0 0 5 Net Wall Area 1 R- 11, 112” As Brd. ` ,'',` ` P• 32 l :,. , 2 ' 895 ,984 ., , 1',701 Area 2 R- 13, 1/2" Asp. Brd. 3A 1 ; ",'. .':"i ' °!' Area 3 R -13 1 /2" Asp. BM- 3.0_ _ , :, :! :.,.( * ";,J11. { 1,,;.''t!' 0 ' 0 p 6 Ceilings Area 1 Attic R- 22 1.9 , !';'`'; , "' ,p "�, ° `', , ;'24'u;E;- 1,080 2,052 2268 Area 2 Attic, R- 19 2.1 Si'' ;,Yi :2 :11 `i ' :, - 0 0 Area 3 Attic R- 19 2.1 ,;'; ells.! .2.3' ,; "' 0 0 7 Floors Area 1 Slab 40.5 , :; ' ' !''0,,t'l ; f , ,���� �, 16 _ 8,784 0 Area 2 None :., ' ` ;'' ' 0.0' ";; l ",i - 1 _ ; n �i -,• 0 0 8 Infiltration Winter Summer Avg Cling Ht ' Poor 1500 - 2100 1.2 !'f;'t " ! ' ; ; ill'! ii 1;f+ 9 5,632 '3,143 ' 9 Sub Total BTUH Loss _ 21,221 10 Duct BTUH Loss 2,122 11 TOTAL HEATING LOAD 23,343 12 People and Appliances _ _ Bedrooms 3 . : 3,000 13 Sub Total BTUH Gain (Structure) - ' ' 14 878 14 Duct BTUH Gain Location 15% 2232 _ 15 TOTAL SENSIBLE '17'110 16 Inflftraton Latent Gain Infit. CFM 97 ' 3 376 17 Peo"le Latent Gain erMIN 2 ,1 200 19 TOTAL LATENT ; 4,578 19 Total Cooling Load ' ia; ' 21",887', 1 • " ev °' rnn yu 42498949 OCEAN STATE_A /C 9 ATLANTIC -BEACH 003/003 mud CERTIFIED 1,4 www.a�ridlractory -ore Certificate of Product Ratings AHRI Certified Reference Number: 3804444 Date: 5/2/2012 Product: Split System: Air- Cooled Condensing Unit, Coll with Blower Outdoor Unit Model Number: 2 4ABB324(A,W)31 Indoor Unit Model Number: FB4CNF024 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: BASE 13 PURON AC Manufacturer responsible for the rating of this system combination Is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and AIr- Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, Independent, third party testing: Cooling Capacity (Btuh): 22800 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13,50 • Ratings followed by an aatarlak (' Indicate a voluntary range or previously published dare, unless accompanied with a WAS which Indicates an involuntary range. DISCLAIMER AHRI does not endorse the product(a) listed an this CertlNoate and Makes no representations, warranties or guarantees as to and assumes no responsibility for, the product(,) listed on this Certificate. AHRI @spreesiy dlscielms ell IlebNtty for thornless of any kind arising out of the use or performance of the productisl, orthe usMWthOrtINd.iteration of data Meted on this Cartlficete. Certified ratings are valid only for models and configurations Noted In the directory at www.ahrkdirectory orp. TERMS AND CONDITIONS This Certiflcets and Its content* are proprietary produote of ANRI. ThIa Certificate MA only be (Hied for Individud personal and confidential referent* purposes. The contents of this Certificate may net, In winds or in gait, by reproduced; copied; disseminated; entered Into a computer database; or otherwise utII td In any forrrr ar manner or by any means, except for the user's Indlveduel, person' and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on MIS certificate can be verified et www.alrridiroctory erg, click on "verify Certificate" Nnk and enter the AHRI Certified Reference Number and the date on Air Refrl teratio , ration ting, which the certificate was issued, which Is listed above, and the Cerdficate No., which le listed below. �� II/ �+ and efr[graticm Institute ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 12980403306463e949