Loading...
Permit Mech 5612 Fleet Landing 2012 r. ' .` ':,`'s CITY OF ATLANTIC BEACH J j 800 SEMINOLE ROAD pti`, A - 4 ATLANTIC BEACH, FL 32233 �a INSPECTION PHONE LINE 247 -5814 Application Number . . . . . 12- 00000553 Date 5/08/12 Property Address 1 FLEET LANDING BLVD MAIN Tenant nbr, name UNIT 5612 Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC FLEET LANDING 6491 POWERS AVENUE 1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 32233 (904) 724 -7211 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 99.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/04/12 Special Notes and Comments UNIT 5612 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (90 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: �- F L c d1 i, �?tul e vur�� i 4 4 - I / G 1 4 1C_ (1, icL PERMIT # i � 3 223 '\../f 1 5612 PROJECT VALUE $ s',so° NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# c 126 i gl1 Air Conditioning: Unit Quantity 1 Tons Per Unit '3 REQUIRED Heat: Unit Quantity 'L BTU's Per Unit 34 to Seer Rating / Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: �� 1 \'t -- * SW 2 - Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give auth rity to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name PC'F L Go i Phone Number ZV C —q 9 o c , Mechanical Company e\ , -/t (5 1''(�'cc `„ %� P Office Phone .77-4 -q z r i Fax 1- 1 -(/ —59 2 S Co. Address: 6 c07 Pc we rS Ave 11 k< City T cLckc c k .ri / le Staten - Zip 3 z 2'? License HoJ + J): P (rei ri/ckt State Certification/Registration # Ci4C G S / ®c N by Notari q ' erase Holder �� -7 //� _ : My Comm. Expires ', Sworn and subscribed before this r° 1--- day of 20 I 'Z • January 10, 2014 : i .1_17,r 1 N• No. DD 950913 • Signature of Notary Public I Job: fl%12012 Right J® Mobile Report Job: - - wra htsoft 9 P Date: 5/8/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904-724 -7211 Fax: 904 - 724 -5925 Email: operez @davidgrayonline.com Pro'ect Information For: Fleet Landing 1 Fleet Landing Blvd. # 5612, Atlantic Beach, FL 32233 Phone: 904- 352 -4101 Email: operez @davidgrayonline.com Desi • n Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry ( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) Method Simplified Wet bulb (°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin • Component Btuh/ft Btuh % of load Walls 3.4 3965 16.4 Glazing 43.9 6020 24.9 irfiitr�m Doors 13.5 425 1.8 Ceilings 2.8 3784 15.7 Floors 4.8 6493 26.9 Infiltration 2.6 3463 14.3 Ass Ducts 0 0 Gaiirg Piping 0 0 Humidification 0 0 Ventilation 0 0 calirgs Adjustments 0 Total 24149 100.0 • Coolin • Component Btuh/ft Btuh % of load Walls 1.5 1776 7.3 Glazing 67.6 9266 37.8 �I IrtarirrfiltIrrla, Doors 11.4 360 1.5 Roots Ceilings 5.9 7961 32.5 Floors 1.8 2402 9.8 Infiltration 0.6 834 3.4 Gaa • Ducts 0 0 Ventilation 0 0 Internal gains 1890 7.7 Blower 0 0 Ceilirt: Adjustments 0 Qher Total 24488 100.0 Latent Cooling Load = 2270 Btuh Overall U -value = 0.148 Btuh /ft - °F Data entries checked. 1 ri htstotlE' 2012- May -08 05:23;00 y'.� Rig ht - Suite ®Universal 2012 12.0.04 Right J® Mobile Page 1 + C: \WNDOWS\ TEMP\ wstmp\ a87bd744- 8b2a- 4b1e- bece- 47186b8be84e.rup Calc =MJ8 Front Door faces: N Job: .fi wrig Project Summary Date: 5/8/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL. 32217 Phone: 904 -724 -7211 Fax: 904 - 724 -5925 Email: operez(8ldavidgrayonline.com Project Information For: Fleet Landing 1 Fleet Landing Blvd. # 5612, Atlantic Beach, FL 32233 Phone: 904- 352 -4101 Email: operez @davidgrayonline.com Notes: Desi • n Information Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 Moisture difference 53 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 24149 Btuh Structure 24488 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24149 Btuh Use manufacturer's data y Rate /swing multiplier 1.00 Infiltration Equipment sensible load 24488 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Structure e Fireplaces 2270 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft 1350 1350 Equipment latent load 2270 Btuh Volume (ft 12150 12150 Air changes /hour 0.45 0.23 Equipment total load 26759 Btuh Equiv. AVF (cfm) 91 47 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Trade Model Cond AHRI ref no. Coil AHRI ref no. Efficiency 0 HSPF Efficiency 13 SEER Btuh Heating input Sensible cooling Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1115 cfm Actual air flow 1115 cfm Air flow factor 0.046 cfm /Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.92 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012 - May -08 05:23:00 Zak "' "' wrIgntsOrL Right- Suite® U niversal 2012 12.0.04 Right J® Mobile Page 1 ^` ak C: \WINDOWS\ TEMP\ wstmp\ a87bd744-8b2a- 4b1e- bece- 47186b8be84e.rup Calc =MJ8 Front Door faces: N lif wrightsoft R i ht-J® Worksheet Job: Date: 51812012 9 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904- 724 -5925 Email: operez(8ldavidgrayonline.com Entire House First Floor 1 Room name 150.0 ft 150.0 6 2 R wall 9 0 ft 9.0 ft heat/cool 3 R000m om h eight 30.0 x 45.0 ft 4 Room dimensions 1350.0 f 1350.0 ft' 5 Room area r r Load I Area (f Load Ty number tuh /fe- Or HTM I or (ft) I (Btuh) or perimeter (ft) (Btuh) number (Btuh /f I (Btuh /ft� f Heat I Cool I Gross I N /P /S I Heat I Cool 1 Gross I N /P /S I Heat 1 Cool 6 1 _C 1 126 -Obw 0.097 n 3. 1.270 n 43.94 3 36 1.50 405 373 1252 561 405 373 1252 561 yVj// 32 0 1406 1160 32 0 1406 1160 12B -Obw B -Obw 0.097 e 3.36 1.50 270 191 639 286 270 191 639 286 1A -clom 1.270 e 43.94 92.64 48 0 2109 4447 48 0 2109 4447 11 11D0 0.390 e 13.49 11.43 32 32 425 360 32 32 425 360 4:097 s 3.36 1 -50'' 405 373 1252 561 405 373 1252 561 14/ 12B -Obw 1.270 s " 43.94 " 41.95 32 0 1406 1342 32 0 1406 1342 V L---G 126 -Obw 0.097 w 3.36 1.50 270 245 822 368 270 245 822 368 � -clom �---G 11A -clom 1.270 w 43.94 92.64 25 0 1099 2316 25 0 1099 2316 C 16A -11aI 0:081 - 2.80 5.90 1350 1350 3784 7961 1350 1350 3784 7961 F 20P -5t 0.139 - 4.81 1.78 1350 1350 6493 2402 1350 1350 6493 2402 6 1 c) AED excursion 1 01 206871 21765 I 20687 21765 Envelope loss /gain 12 a) Infiltration 3463 834 3463 834 b) Room ventilation 0 0 0 0 3 690 3 690 13 Internal gains: Occupants 230 1200 1200 Appliances/other ther Subtotal (lines 6 to 13) 24149 24488 24149 24488 Less external load 0 0 0 0 Less transfer 0 0 0 0 0 0 0 Subtot bution a 24149 24488 14 Subtotal 24149 24488 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 I I TAor tal requir room ed loa(cd m) I I I 2 11 4 151 2 11851 I I 2 1115 I 2 11 8 15 i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012- May -08 05:23:00 V4irig 7t9S?ft Right- Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 CAVV1NDOWS\ TEMP\ wstmp\ a87bd744- 8b2a -4b1e- bete- 47186b8be84e.rup CaIc =MJ8 Front Door faces: N 4 w ghtsoft Job: Component Constructions Date: 5/8/2012 Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 -724 -7211 Fax: 904 - 724 -5925 Email: operez @davidgrayonline.com Pro - ect Information For: Fleet Landing 1 Fleet Landing Blvd. # 5612, Atlantic Beach, FL 32233 Phone: 904 -352 -4101 Email: operez @davidgrayonline.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 0 35 16 Latitude: 30°N Relative humidity ( /o) 30 50 Outdoor: Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Simplified Daily range ( °F) - 17 (M ) Method P Wet bulb ( °F) 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain ft. Btuh/ft.-°F ft' - °F /Btuh Btuh /ft' Btuh BtuhHN Btuh Walls 12B -0bw: Frm wall, brk 4" ext, r -11 cav ins, 1/2" gypsum board int n 373 0.097 11.0 3.36 1252 1.50 561 fnsh, 2 "x4" wood frm e 191 0.097 11.0 3.36 639 1.50 286 s 373 0.097 11.0 3.36 1252 1.50 561 w 245 0.097 11.0 3.36 822 1.50 368 all 1182 0.097 11.0 3.36 3965 1.50 1776 Partitions (none) Windows 1A -c1 om: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk n 32 1.270 0 43.9 1406 36.3 1160 e 48 1.270 0 43.9 2109 92.6 4447 s 32 1.270 0 43.9 1406 41.9 1342 w 25 1.270 0 43.9 1099 92.6 2316 all 137 1.270 0 43.9 6020 67.6 9266 Doors 11 D0: Door, wd sc type e 32 0.390 0 13.5 425 11.4 360 Ceilings 16A -11 al: Attic ceiling, asphalt shingles roof mat, r -11 ceil ins, 1/2" 1350 0.081 11.0 2.80 3784 5.90 7961 gypsum board int fnsh Floors 20P -5t: Fir floor, wd flr, 1" thkns, tile flr fnsh, r -5 ext ins, amb ovr 1350 0.139 5.0 4.81 6493 1.78 2402 2012- May -08 05:23:00 . '" : ' Wright:Sa Rig ht Univer 2012 12.0.04 Right J® Mobile Page 1 ACak C:WVINDOWS\ TEMP \wstmp \ a87bd744- 8b2a -4b1 e- bete- 47186b8be84e.rup Catc = MJ8 Front Door faces: N Job: AED Assessment Date: 518/2012 " WC1��15f Entire House By: Oniel Perez David Gray Heating & Air, Inc 6491 Powers Ave., Jacksonville, FL 32217 Phone: 904 - 724 -7211 Fax: 904 - 724 -5925 Email: operez(flJdavidgrayonline.com Project Information For: Fleet Landing 1 Fleet Landing Blvd. # 5612, Atlantic Beach, FL 32233 Phone: 904- 352 -4101 Email: operez @davidgrayonline.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Design TD ( °F) 35 16 Lattititudd : 30 °N Elevation: 43 ft Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (gr /Ib) 8.4 52.8 Dry bulb ( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) V1ibt bulb (°F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Glazing Hourly Load 12,000 11,000 - 10,000— ,....,....�.-- •."'""" 8,000 - 7, 6,000 — 5,000— 4,000— 3,000— 2,000— 1,000 — 08 1 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / Harty Aerage PEDlimit Maximum hourly glazing Toad exceeds average by 12.2 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh 2012- May -08 05:23:00 vvrighit of Right- Suite® Universal 2012 12.0.04 Right J® Mobile Page 1 : \W CINDOWS\ TEMP\ wstmp\ a87bd744- 8b2a- 4b1e- bece- 47186b8be84e.rup Calc = MJ8 Front Door faces: N sou CERTIFIEDTM www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4261913 Date: 5/8/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air- Source Outdoor Unit Model Number: GSZ130361B* Indoor Unit Model Number: AR *F363616C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 35000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 33600 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 20800 • Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirecto 0 g TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION 11112111 The information for the model cited on this certificate can be verified at www.ahridirectory.org, �■ "� 4 Air Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129809622152891260