Permit Mech 1571 Linkside 2012 Vtit f CITY OF ATLANTIC BEACH ,*, ! j - 800 SEMINOLE ROAD 0 2 %' ATLANTIC BEACH, FL 32233 ��� '� INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000565 Date 5/09/12 Property Address 1571 LINKSIDE DR Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor MOORHEAD MICHAEL M & JOAN M WEATHER ENGINEERS INC. 1571 LINKSIDE DR 1000 EDISON AVENUE ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32204 (904) 356 -3963 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 95.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/05/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 95.00 95.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 99.00 99.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 ` l Ph (904) 247 Fax (904) 247 -5845 L 1 JOB ADDRESS: ' 51 1 n t d O e. r .. PERMIT # PROJECT VALUE $ L I Lo 51) . O 0 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATIO ARI # U14a ?,p Air Conditioning: Unit Quantity 1 Tons Per Unit a .5 REQUIRED Heat: Unit Quantity k BTU's Per Unit 3U, ODD Seer Rating 1 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct_ All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name fTh Gha € , 010 DY head) Phone Number (9IS } q - 3 151 Mechanical Company u3ecA+fEY' EY19 l nC PY S, I C)C • Office Phone (P 3 6'ax s t0` G Co. Address: P .0 O f D k_o City (J0.)( Statt' L- Zip3 3 U1 License Holder (Print O rules - Y s J . i') U r - State Certification/Registration 4 C. O 41 IGO Notarized Signature of License Holder Swum subscribed befo e th t� day of m f.- 201 —. - Astlt"Er �. vNia a S ignature of Notary Publ � ► _ , r . — �� � �' � \ pocr P� - slw a f�aies I 1 My Comm. Expires Jan 24.2016 i �:,, p7iv , o . Commission a EE 166056 1, ' d 91789 L17Z 0 All OswelsAS uol}ew -I0Jul d917:1.0 01. 61. MAI Project Summary Job: Date: May 09, 2012 Entire House By: Weather Wengineers, Inc. 1000 Edison Ave, Jacksonville, FL 32204 Phone: 904-356-3963 Fax 904-356 -4969 Email: galexander©weatherengineers.com Web: wwwweatherengineers.com Project Information For. MICHAEL MOORHEAD 1571 LINKSIDE DR, ATL BCH, FL32233 Notes: Desi • n Information Weather. Washington National AP, DC, US Winter Design Conditions Summer Design Conditions Outside db 17 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 53 °F Design TD 16 °F Daily range M Relative humidity 50 Moisture difference 35 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 26936 Btuh Structure 15975 Btuh Ducts 6065 Btuh Ducts 5696 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33001 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 20805 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 961 Btuh Ducts 931 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 1530 1530 Equipment latent load 1892 Btuh Volume (ftl 12240 12240 Air changes /hour 0.38 0.20 Equipment total load 22697 Btuh Equiv. AVF (cfm) 78 41 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref no. Coil AHRI ref no. Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 913 cfm Actual air flow 913 cfm Air flow factor 0.028 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.92 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Wri ht5tD1't° 2012- May - 0910:15:48 9 Comfort Builder by Wrightsott 12.0.06 RSU04554 Page 1 Aa5k Projedl.rup Caic =MJ8 Front Door faces: N "INmu1 CERTIFIEDTM www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3699906 Date: 5/9/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 213BN(A,W)030 * * * *A Indoor Unit Model Number: FB4CNF030 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade /Brand name: LEGACY 13 PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 30000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 30000 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh) @ 17 F: 18300 • Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION um, The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on �® + Air Heating, which the certificate was issued, which is listed above, and the Certificate No., which is listed below. and Refrigeration Institute ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129810584733269880 i