Loading...
Permit 156 Belvedere (vault) ?I % 'Y.r`.► ' *1 CITY OF ATLANTIC BEACH « ` P 800 SEMINOLE ROAD r � ATLANTIC BEACH, FL 32233 ro ~ ° ~ 1 � INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000582 Date 5/11/12 Property Address 156 BELVEDERE ST Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 CU 1 AHU Owner Contractor DOWNING GERALD M HUXHAM HEATING & AIR 156 BELVEDERE 2101 FLORIDA BLVD. ATLANTIC BEACH FL 322334107 NEPTUNE BEACH FL 32266 (904) 246 -6721 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 99.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/07/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 99.00 99.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 103.00 103.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: ) S (o &...'Jt4JU4-- PERMIT # PROJECT VALUE $ o ` � o Co - G� ARI # ,So .PI S1 tl REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity / Tons Per Unit Heat: Unit Quantity i BTU's Per Unit 3 6, of d Seer Rating / 5 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 2t) l _-_J Phone Number Mechanical Company frA/XA4», ,,n fli$ I�c PI C.._ Office Phone 9%z'2 / Fax Co. Address: awl 1 lOvZ- o9IQ f, (... City f) {1 &CI Stated/ Zip32c License Holder (Print): Z rt c5 Cr' 1 State Certification/Registration # 07-COS ?P-S ...4_\.3. Notarized Signature of License Holder ., S o rn d subscribed before me this day of 20 Signature of Notary Public Job: 51112 Project Summary Job: May 10, 2012 1 Entire House By: Erin Rodriguez Pro'ect Information For: Dowling 156 Belvedere Street, Atlantic Beach, FL 32233 Notes: HUXHAM - a/c install Desi • n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 76 °F Design TD 29 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 56 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21055 Btuh Structure 16967 Btuh Ducts 4330 Btuh Ducts 6006 Btuh Central vent (34 cfm) 1090 Btuh Central vent (34 cfm) 602 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment Toad 26476 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 22868 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1736 Btuh Ducts 1498 Btuh Heating Cooling Central vent (34 cfm) 1302 Btuh Area (ft 171D 1710 Equipment latent load 4537 Btuh Volume (ft 13680 13680 Air changes /hour 0.38 0.20 Equipment total load 27404 Btuh Equiv. AVF (cfm) 87 46 Req. total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make TRANE Make TRANE Trade Trade Model 4TWR5036 Cond 4TWR5036 ARI ref no. 5021594 Coil GAM5AOB36 ARI ref no. 5021594 Efficiency 0 HSPF Efficiency 0 EER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47 °F Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 920 cfm Actual air flow 920 cfm Air flow factor 0.036 cfm /Btuh Air flow factor 0.040 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -I4.i- wrigt+tsoft ° ' Right- Suite® Universal 7.1.09 RSU01508 2012- May -11 10:51:16 ACCP• C:1 Users \erin \ Documents \Wrightsoft HVAC \Template \Dowling- Huxham.rup Calc = MJ8 Orientation = E Page 1 This combination qualifies for a Federal Energy A CERTIFIED-. Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2011. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 5021594 Date: 5/11/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 4TWR5030G1 Indoor Unit Model Number: GAM5A0B36M31 Manufacturer: TRANE Trade /Brand name: XR15 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 32200 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 28800 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 17900 • Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.arg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air - Conditioning, Heating, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on ■I■ r ® and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129812331288724684