Permit Mech 1850 Beach Ave 2012 C s
' l CITY OF ATLANTIC BEACH ilk r) 800 SEMINOLE ROAD
* .., v ATLANTIC BEACH, FL 32233
; , ; INSPECTION PHONE LINE 247 -5814
E F
Application Number . . . 12- 00000597 Date 5/16/12
Property Address 1850 BEACH AVE
Application type description MECHANICAL HVAC ONLY
Property Zoning . ... . . . . TO BE UPDATED
Application valuation . . . . 3200
Application desc
CHANGE OUT 2 TON SYSTEM ARI 3717803
Owner Contractor
MCDANIEL FLEMING N JR TRUST HOLLAND AC & HEATING SERVICE
1850 BEACH AVE 5000 -18 HWY 17 #52
ATLANTIC BEACH FL 322335939 ORANGE PARK FL 32003
(904) 813 -3820
Permit MECHANICAL HVAC PERMIT
Additional desc . CHANGE OUT 2 TON SYSTEM
Permit Fee . . . 91.00 Plan Check Fee . . .00
Issue Date Valuation . . . . 0
Expiration Date . . 11/12/12
Other Fees STATE MECH DCA SURCHARGE 2.00
STATE MECH DBPR SURCHARGE 2.00
Fee summary Charged Paid Credited Due
Permit Fee Total 91.00 91.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 4.00 4.00 .00 .00
Grand Total 95.00 95.00 .00 .00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
( Ph (904) 247 -5826 Fax (904) 247 -5845
JOB ADDRESS: 1 0 Deck L h ea") e ,---, 0 e PERMIT #
P R O J E C T V A L U E $ S Z o o c ' ° ARI # 37 1 -7 e O 3
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity / Tons Per Unit Z 3 717 803
Heat: Unit Quantity BTU's Per Unit 2y�o Seer Rating /.350
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name fr f C rn,' 11 c 1 9 a n e l ` 1 Phone Number 2 1 17 - 5 5
Mechanical Company / -Fri / 1 O'‘ A e ? , Office � r3 - 3� z
Y � e Ph one zo Fax�jcyz�yy /G
Co. Address: 5 a 00 - / -f/„r y / / )4-54-2- / / City O lteUGC fit. State r1 Zip 32oa
License Holder (Print): -- ∎ l' 1 /l - �i/ �' � tate Ce • ification/Registration # X40 6 7 /33
Notarized Sign ,re o License Holder 8i_ — 111
�_ / .,
_! t OEeOwwAMnN anr d subscribed before m this (� day o 20 42
= �'i , MY COMMISSION # EE 057,) , '
'•- �. .•:,€ E Bonded 7hru Notary pub XPIRES: Ma ?�y �r i5 gr�atur t of Notary Public � --t - �-
�. _ �
7-- 5 - 13,)._ 907 0
JOB NAME: FLEMING MCDANIEL
1850 BEACH AVE
ATLANTIC BCH, FL 32223
3RD ZONE TOP FLOOR 13SEER
FRONT DOOR FACES EAST
•
2TON COMFORTMAKER
N /FEM4P2400AT ARI3717803
Desi • n Information
Weather: Jacksonville, Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db Outside db
Inside db 72 °F Inside db 72 °F
Design TD 40 ° 72 °F
Design TD 21 °F
Daily range
Relative humidity 5
Moisture difference 58 grill)
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 7100 Btuh Structure
Ducts 1379 Btuh Ducts 14 Btuh
Central vent (14 cfm) 0 Btuh Central vent (14 cfm) 489 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping
Euiment Toad 8479 Btuh Use manufacturer's data
Rate /swing multiplier n
Infiltration Equipment sensible load 19346 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
quality uali ty ag
Fireplaces 0 Structure 1511 Btuh
Ducts 546 Btuh
Heating Cooling Central vent (14 cfm) 0 Btuh
Area ft 525 525 Equipment latent load 2057 Btuh
Volume (ft 4200 4200
Air changes/hour 0.37 0.19 Equipment total load 21403 Btuh
Equiv. AVF (cfm) 26 13 Req. total capacity at 0.85 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make n/a
Trade n/a Trade n/a
Model n/a Cond n/a
Coil n/a
Efficiency n/a Efficiency Input Sensible cooling Na
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 0 cfm Actual air flow 0 cfm
Air flow factor 0.000 cfm /Btuh Air flow factor 0.000 cfm/Btuh
Static pressure 0.00 in H2O Static pressure 0.00 in H2O
Space thermostat n/a Load sensible heat ratio
0.00
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
a wrightsoft Right-Suite Residential 6.0.119 RSR29784 2012 - Mar -27 10:32:01
ACCR. E:\EDS1Cur ent\Residential Changeout Manual JMHolland, Atallah Residence. 3044 Southside Blvd, Jax
Page 1