Loading...
Permit Mech 1850 Beach Ave 2012 C s ' l CITY OF ATLANTIC BEACH ilk r) 800 SEMINOLE ROAD * .., v ATLANTIC BEACH, FL 32233 ; , ; INSPECTION PHONE LINE 247 -5814 E F Application Number . . . 12- 00000597 Date 5/16/12 Property Address 1850 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . ... . . . . TO BE UPDATED Application valuation . . . . 3200 Application desc CHANGE OUT 2 TON SYSTEM ARI 3717803 Owner Contractor MCDANIEL FLEMING N JR TRUST HOLLAND AC & HEATING SERVICE 1850 BEACH AVE 5000 -18 HWY 17 #52 ATLANTIC BEACH FL 322335939 ORANGE PARK FL 32003 (904) 813 -3820 Permit MECHANICAL HVAC PERMIT Additional desc . CHANGE OUT 2 TON SYSTEM Permit Fee . . . 91.00 Plan Check Fee . . .00 Issue Date Valuation . . . . 0 Expiration Date . . 11/12/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 91.00 91.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 95.00 95.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 ( Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: 1 0 Deck L h ea") e ,---, 0 e PERMIT # P R O J E C T V A L U E $ S Z o o c ' ° ARI # 37 1 -7 e O 3 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity / Tons Per Unit Z 3 717 803 Heat: Unit Quantity BTU's Per Unit 2y�o Seer Rating /.350 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name fr f C rn,' 11 c 1 9 a n e l ` 1 Phone Number 2 1 17 - 5 5 Mechanical Company / -Fri / 1 O'‘ A e ? , Office � r3 - 3� z Y � e Ph one zo Fax�jcyz�yy /G Co. Address: 5 a 00 - / -f/„r y / / )4-54-2- / / City O lteUGC fit. State r1 Zip 32oa License Holder (Print): -- ∎ l' 1 /l - �i/ �' � tate Ce • ification/Registration # X40 6 7 /33 Notarized Sign ,re o License Holder 8i_ — 111 �_ / ., _! t OEeOwwAMnN anr d subscribed before m this (� day o 20 42 = �'i , MY COMMISSION # EE 057,) , ' '•- �. .•:,€ E Bonded 7hru Notary pub XPIRES: Ma ?�y �r i5 gr�atur t of Notary Public � --t - �- �. _ � 7-- 5 - 13,)._ 907 0 JOB NAME: FLEMING MCDANIEL 1850 BEACH AVE ATLANTIC BCH, FL 32223 3RD ZONE TOP FLOOR 13SEER FRONT DOOR FACES EAST • 2TON COMFORTMAKER N /FEM4P2400AT ARI3717803 Desi • n Information Weather: Jacksonville, Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db Outside db Inside db 72 °F Inside db 72 °F Design TD 40 ° 72 °F Design TD 21 °F Daily range Relative humidity 5 Moisture difference 58 grill) Heating Summary Sensible Cooling Equipment Load Sizing Structure 7100 Btuh Structure Ducts 1379 Btuh Ducts 14 Btuh Central vent (14 cfm) 0 Btuh Central vent (14 cfm) 489 Btuh Humidification 0 Btuh Blower 0 Btuh Piping Euiment Toad 8479 Btuh Use manufacturer's data Rate /swing multiplier n Infiltration Equipment sensible load 19346 Btuh Method Simplified Latent Cooling Equipment Load Sizing quality uali ty ag Fireplaces 0 Structure 1511 Btuh Ducts 546 Btuh Heating Cooling Central vent (14 cfm) 0 Btuh Area ft 525 525 Equipment latent load 2057 Btuh Volume (ft 4200 4200 Air changes/hour 0.37 0.19 Equipment total load 21403 Btuh Equiv. AVF (cfm) 26 13 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a Coil n/a Efficiency n/a Efficiency Input Sensible cooling Na Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0.000 cfm /Btuh Air flow factor 0.000 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat n/a Load sensible heat ratio 0.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. a wrightsoft Right-Suite Residential 6.0.119 RSR29784 2012 - Mar -27 10:32:01 ACCR. E:\EDS1Cur ent\Residential Changeout Manual JMHolland, Atallah Residence. 3044 Southside Blvd, Jax Page 1 1