Loading...
Permit Mech 1835 Seminole 2012 di 5 d � CITY OF ATLANTIC BEACH ) 800 SEMINOLE ROAD 0 .4..."-.1 ATLANTIC BEACH, FL 32233 ,' Diu - n, INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000591 Date 5/15/12 Property Address 1835 SEMINOLE RD Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 3800 Application desc CHANGE OUT 2 TON SYSTEM Owner Contractor WATERS JANICE B TROPIC HEATING & AIR 1835 SEMINOLE RD 750 MAYPORT RD ATLANTIC BEACH FL 322335915 ATLANTIC BEACH FL 32233 (904) 241 -1788 Permit MECHANICAL HVAC PERMIT Additional desc . CHANGE OUT 2 TON SYSTEM Permit Fee . . . 91.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date . . 11/11/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 91.00 91.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 95.00 95.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. A MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247 -5845 JOB ADDRESS: fS 3S Si°m 'M el60 /' t PERMIT # /+Z ( PROJECT VALUE $ gaD `""" / NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # 3, 75//3 Air Conditioning: Unit Quantity / Tons Per Unit 2 REQUIRED Heat: Unit Quantity / BTU's Per Unit Seer Rating /5 5 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets — Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name GR �. c r L�/a i s Phone Number oz 5 2 9f7 Mechanical Company try < (4-e w . r Office Phone 2 Fax .2(/7 'V 72 Co. Address: 7 5 71/1 a. i o c -t,1 Al City At , S State I . Zip 3 2-2- � License Holder (Print): Pycl- � �S - . State Certification/Registration # CACC5 431 Notarized Signature of License Holder KAREN E. PANTFOEDER Sworn and subscribe before me this 1 L i day of (a y 201 NOTARY PUBLIC Signature of Notary Public 74,1(.0. t fat,i,wcab-1/4. STATE OF FLORIDA • = Comm# EE064448 • • Expires 3/4/2015 s6N6 d #i O 2 AmM1166'6'6 Asm O�e . ,g,. . , ntw'� ' a . ' .. . ,,,,,,, V. - .. , .. , -=' , .. , ...”. ,,,,,,,,,,, ��� . ., ;.-i q. , wr �� t �u i ; z t This combination qualifies for a Federal Energy V ��° Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2011 u. C ertifl c a t e . P r oci uc t " � +�� 2 * X 83 -fir t 5: A zF:'^'.s' ?,tii .P. +.,_u .n st ,u . S',C Tkte3`4W$$tS°.4 4444-?'-:.5h..,c.44 *4444 .s MB..444K:.. *✓ , PV.Mt :,:, . 4,t.MO.wn T , fi .. } , .t, .4N€C ..£444.4sa 44448 YMTOSSFi:'W,T, 44,•4. 4 444 G' 3.d`.b:70A,,,..,nFY.., i .xY� . { AHRI Certified Reference Number: 3647413 Date: 5/15/2012 t 1 _ Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source S f Out door Unit Model Number: 215BNA024****A v , Indoor Unit Model Number. FX4DNF025 v Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY 15 PURON HP fi ` Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING t SYSTEMS : 6 Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source s Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third i'. : party testing: W Cooling Capacity (Btuh): 24000 z° EER Rating (Cooling): 12.50 .. SEER Rating (Cooling): 15.25 Heating Capacity(Btuh) @ 4 7 F: 24000 Region IV HSPF Rating (Heating): 8. i , F ll Heating Capacity(Btuh) @ 17 F: 14700 s 4{ ; $ t { S )F ; , $ P l ` t * Ratings followed by an asterisk r) indicate a voluntary rerate of previously published data, unless accompanied with a WAS which indicates arsinvoluntary rerate 4,, • . sttt433a+m . >wr,.. .x .,r',3�x'r ;x_i,+f� r :'x+.s.+51v. 44 .443X, u'!Ma... T'= :b .d, it �,..__• -Kea ,,. 44 t +... .at. .+ F.c.� ..4v _ ..e . /av ..+'�.� .X, .. . _. .... t : r DISC L LA IMER AHRI does not endorse the products) fisted on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations Listed in the directory at TERMS AND CONDITIONS 1 1 This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. t , r The contents of this Certificate may not in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any 4, form or manner or by any means, except for the user's individual, personal and confidential reference, r CERTIFICATE VERIFICATION y ;} i , i , t The information for the model cited on this certificate can be verified at . t i " " ' � � tr i R click on " t„ , ' -. ° link and enter the AHRI Certified Reference Number and the date on i " °'fi ii which the certificate was issued, which is listed above, and the Certificate No., which is listed bellow. r:. i 1 ©2012 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129815565115593027 A "r . ti,, .,. ,,rAd,MWA' rvV £ .,. at. `.w :« ,.a 'SBA T A=:^ 29a ,K'M -. ,.. -=L,rW a:' rskA :?:.�., = 7'st..wpvv4 'i WkA i4N4f aa'4 'lS a c :te ik' :S' WfVA'a' Z'A7aW s r Project Summary mob: ry a t ry Date: 5/14/2012 Entire House By: Brent Reedy act SSP= Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904-241 -1788 Fax: 904-241 -2172 Email: BrenLtropicacCattnet Web: wwwtropicheatandac.com License: CACO52431 Pro t Information For: Janice Waters 1835 Seminole Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -2984 Email: Tropicaccrosn.com Notes: Desi t n lrtfor 'tatiio Weather: Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13706 Btuh Structure 15061 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13706 Btuh Use manufacturer's data y Rate /swing multiplier 1.00 Infiltration Equipment sensible load 15061 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1825 Btuh Ducts 0 Btuh Heating Coolin Central vent (0 cfm) 0 Btuh Area (ft 625 625 Equipment latent Toad 1825 Btuh Volume (fr3) 5000 5000 Air changes/hour 0.79 0.41 Equipment total load 16886 Btuh Equiv. AVF (cfm) 66 34 Req. total capacity at 0.70 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref no. n/a Coil AHRI ref no. Efficiency n/a Efficiency 0 SEER Heating input 0 Btuh Sensible coding 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total coding 0 Btuh Actual air flow 0 cfm Actual air flow 686 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.046 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft 2012- May - 1417:51:49 Right -Suite, Universal201212.0.04 Right JO Mobile Page 1 ''''' C:IWINDOWSITEMPt t3820ed35•d241- 490x- 81ot -677c93834c2.rup Calc = MJ8 Front Door faces N Eb ryant Component Constructions Job: P Date: 5/14/2012 Entire House By: Brent Reedy fkiortiel + cooku finties Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -1788 Fax 904-241 -2172 Email: Brent.tropicacCattnet Web: www.tropicheatandac.com License: CACO52431 Pro`ect Information For: Janice Waters 1835 Seminole Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -2984 Email: Tropicac@msn.com Design Co di ions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (grfb) 8.4 52.8 Dry bulb( °F) 35 91 Infiltration: Dailyrange ( °F) - 17 (M ) Method Simplified Vlkt bulb ( °F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain tF B6hfP - °F 11'- °F/Blh BYh/Ir Btuh BtJVR' Btuh Walls 12B -Obw: Frm wall, brk 4" ext, r -11 cav ins, 1 /2" gypsum board int ne 170 0.097 11.0 3.36 571 1.50 256 fnsh, 2 "x4" wood frm se 170 0.097 11.0 3.36 571 1.50 256 sw 170 0.097 11.0 3.36 571 1.50 256 nw 170 0.097 11.0 3.36 571 1.50 256 all 680 0.097 11.0 3.36 2282 1.50 1022 Partitions (none) Windows 1A -c1om: 1 glazing, clr glz, mtl no brk frm mat, 1/8" thk ne 30 1.270 0 43.9 1318 70.9 2126 se 30 1.270 0 43.9 1318 74.1 2224 sw 30 1.270 0 43.9 1318 74.1 2224 nw 30 1.270 0 43.9 1318 70.9 2126 all 120 1.270 0 43.9 5273 72.5 8700 Doors (none) Ceilings 16B -19ad: Attic ceiling, asphalt shingles roof mat, r -19 ceil ins, 1/2" 625 0.049 19.0 1.70 1060 2.59 1617 gypsum board int fnsh Floors 19A- Obvtp: Fir floor, wd flr, 1" th tile flr fnsh, leaky bsmt ovr 625 0.368 0 4.14 2589 1.95 1220 :,,.. - t{+ wrightsoft 2012- May -1417: P 9 Right -Su Re ®Universal 2012 12.0.04 Right J® Mobile Page 1 4 : - -C- 4 ' C: tWWNDOWSITEMP wstm 13820ediSd241 -490a- 8101- B77c93ff34c2.rup CaIc = MJ8 Front Door faces, N Lliryant Right-J® Worksheet Job: Date: 5/14/2012 ��- Entire House +.+t 0 M0 SWIM By: Brent Reedy Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904-241 -1788 Fax: 904 -241 -2172 Email: Brent.tropicac®lattnet Web: www.tropicheatandac.com License: CACO524... 1 Room name Entire House First Floor 2 Exposed well 100.0 ft 100.0 ft 3 Room height 8.0 ft d 8.0 ft heat/cool 4 Room dimensions 25.0 x 25.0 ft 5 Room area 625.0 ft' 625.0 ft r 1 1 1 1 r Ty Construction U -value Or HTM Area (f I Load I Area (f Load number (Btuh/ff - °F) I (Btuh/ftl ( or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) I Heat I Cool I Gross I N/P/S I Heat I Cool I Gross I WP /S Heat I Cool 1 6 y� 128 -Obw 0.097 ne 3.38 1.50 200 170 571 256 200 170 571 256 t—G 1A -c1om 1.270 ne 43.94 70.87 30 0 1318 2128 30 0 1318 2126 W 128-Obw 0.097 se 3.36 1.50 200 170 571 256 200 170 571 258 r--G 1A -clom 1.270 se 43.94 74.13 30 0 1318 2224 30 0 1318 2224 11 Yy 12B-Obw 0.097 sw 3.36 1.50 200 170 571 256 200 170 571 256 L —G 1A -clom 1.270 sw 43.94 74.13 30 0 1318 2224 30 0 1318 2224 yy 12B -Obw 0.097 nw 3.36 1.50 200 170 571 256 200 170 571 256 L---G 1A -clom 1.270 nw 43.94 70.87 30 0 1318 2128 30 0 1318 2126 C 16B-19ad 0.049 1.70 2.59 625 625 1060 1817 625 625 1060 1817 F 19A -Obvtp 0.388 - 4.14 1.95 625 825 2589 1220 625 625 2589 1220 1 6 1 cEnvelope ) AED excursion 0 0 loss/gain I I 112041 12559) I 11204 I 125591 12 a) Infiltration 2502 612 2502 612 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Applianceslother 1200 1200 Subtotal (lines 8 to 13) 13706 15061 13708 15061 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 13706 15061 13706 15061 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total room bad I I I 137 O) 15081 I I I 13706 15061 I Air required (cfm) l Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 44 wrightsoft 2012- May - 1417:51:49 e':f. Rig -Su tee/ Universal 2012 12.0.04 Right JO Mobile Page 1 C: tW1NDOWSITEMPtwstrnp \3620ed35 -d241- 490x- 810f- 677c93ff34c2.rup Cab = MJ8 Front Door faces: N Right J® Mobile Report 5/14/2012 Entire House By: Brent Reedy antes a Costal >< . Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904 -241 -1788 Fax: 904 -241 -2172 Email: Brenttropicactjattnet Web: www.tropicheatandac.com License: CACO52431 Pro ec't inffrmlatiofn For: Janice Waters 1835 Seminole Rd., Atlantic Beach, FL 32233 Phone: 904- 241 -2984 Email: Tropicac@msn.com Des • n Cond Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (grfb) 8.4 52.8 Dry bul b ( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) Method Simplified Vlkt bulb ( °F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 "�eat E Component Btuhlf1 Btuh % of load Walls 3.4 2282 16.7 VVIs IrfitrA n Glazing 43.9 5273 38.5 Doors 0 0 0 Ceilings 1.7 1060 7.7 Floors 4.1 2589 18.9 Flom 3.1 2502 18.3 Ducts 0 0 Piping 0 0 H Gatirg umidification 0 0 cblirgs Ventilation 0 0 Adjustments 0 Total 13706 100.0 Cooif • Component Btuh/ft Btuh % of load Walls 1.5 1022 6.8 Wills Ir>berr>� �� Glazing 72.5 8700 57.8 Doors 0 0 0 Wilt-dial Ceilings 2.6 1617 10.7 ;,l Floors Floors 2.0 1220 8.1 Infiltration 0.8 612 4.1 Ducts 0 0 Ventilation 0 0 Ceiiir� Internal gains 1890 12.5 /` Blower 0 0 Gazkg Adjustments 0 Total 15061 100.0 Latent Cooling Load = 1825 Btuh Overall U -value = 0.234 Btuh/ft? -- °F Data entries checked. Wrigi7tSt7ft Ri S U 12.0.04 Right JO Mobile 2012- May- 1417:51:49 Page 1 -. C:MINDOWSITEM 41- 490x- 810f -677c93R34c2.rup Cate = MJ8 Front Door faces: N brYaii] AED Assessment Job: Date: 5/14/2012 Entire House By: Brent Reedy I Tropic Heating & Air Conditioning Inc. 750 Mayport Rd., Atlantic Beach, FL 32233 Phone: 904-241 -1788 Fax: 904- 241 -2172 Email Brenttropicaceatt net Web: www.tropicheatandac.com License: CACO52431 Project information For: Janice Waters 1835 Seminole Rd, Atlantic Beach, FL 32233 Phone: 904- 241 -2984 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville /Craig, FL, US Indoor temperature ( °F) 70 75 Elevation: 43 ft Design TD ( °F) 35 16 Latitude: 30 °N Relative humidity ( %) 30 50 Outdoor: Heating Cooling Moisture difference (grfb) 8.4 52.8 Dry bulb( °F) 35 91 Infiltration: Daily range ( °F) - 17 (M ) V1et bulb (°F) - 77 Wind speed (mph) 15.0 7 -5 Test for Adequate Exposure Diversity Hourly Glazing Load 11,00: 10,01: 9,00: 8,00: 7,C10: «P 5,000 4,000 3,000 2,000 1,00: 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hourly Aerage ,d fieDlirrit Maximum hourly glazing load exceeds average by 21.4 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh 2012- May- 1417:51:50 wriglILSOfL Right- Bute!) Universa12012 12.0.04 Right J® Mobile Page l C: WNNDOWSITEMPIwstrnp13820ed35 -d241- 490x- 810f- 677c93ff34c2.rup Cat = Ma Front Door faces: N