Loading...
Permit Mech 1484 Laurel Way 2012 N) MW CITY OF ATLANTIC BEACH r ai I s) 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 DOE Application Number 12- 00000432 Date 5/17/12 Property Address 1484 LAUREL WAY Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 CU 1 AHU Owner Contractor FARROKH FIROUZ OWNER 1484 LAUREL WAY ATLANTIC BEACH FL 32233 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 107.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/13/12 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 107.00 107.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 111.00 111.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 ,+ Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: `` //�� -1' $ 4 L_a u re ` W Q■ , 30,(33 PERMIT # PROJECT VALUE $ 4 - 1O CO NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # 3 to s.9 4}8 Air Conditioning: Unit Quantity 1 Tons Per Unit REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating 14 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name N 1 01 'F Dl VT 0 k11 Phone Number 3 a - g 5 51c Mechanical Company A11 11\ C WI±V(x.0: t , { na. Office Phone 1 A 1- IDOL:Fax - 7 s i - 105 1 Co. Address: 1 Iii (myl o ndy z1 \Jd City J P Y State *F L Zip 3 a a License Holder (Print): Pa+ y I ( k. F 10 YY State Certification/Registration # O(Y 1 Notarized Signature of License Holder �t o Sworn and subscribed before me this ( F7tH day of Pr- 2..- __ 20 I a ArieVii HEATHER LYNN STAGGSS gnature of Notary Public A Commission # EE 043708 a Expires November 21, 2014 Bonded Ttru Troy Fain Insurance 8003867019 Customer Information Location: Street Address 1484 Laurel way, DUVAL, FL 32233 Latitude, Longitude 30.3375°, -81.7686° House Square Footage: 2108 sq. ft. Name: Nick Farrokh Phone: Email: Desi n Conditions Outdoor Heating Cooling Dry bulb (°F) 32 93 Daily range Relative humidity 50% Moisture difference 53 Ind oor Heating Cooling Indoor tetrtpcorature (° F) 70 75 Design temperature difference(°F) 38 18 Heatin• Loads Area Btuh % of load Wall 3508 9.5 Floor 10093 27.5 Ceiling 4246 11.5 Windows 5738 15.6 Intiltrediciel 9834 26.8 System Efficiency Loss 3342 9.1 Total: 36759 Heating Loads System Efficiency Loss Floor Wall Ceiling / Windows Infiltration Coo lirt# Loads Area B 16 t 6 u 2 h 3 5 ° f I° a d Wall 5 Sensible Infiltration 54 Ceiling 2011 4.2 26163 . 1Afindoals 3494 7.3 6359 13.3 Latent Itifiltratico 3969 8.3 Efficiency Gain System tntemal 2365 4.9 Sensible People Load 970 2 2 Latent People Lced Total: 47961 Sensible load 40633 Latent load 0.85 SHR Capacity at . 75 4.51 TcrIS 75 SHR . - Cooling Loads <,. Sensible People Load I . Latent People Load r r -- Wall . Ceiling „ — Internal ,,. , • ,...„. .- ”. Sensible Infiltratio ..,. Windows ---- ----- System Efficiency \ Latent Infiltration * Ade. irate Ex. osure Diversi' AED Graph 40000 30000 7( 10000 Sarre Oars loam 1100> 12prmi 1prn 2p n 3 m 10r1 6pmn 7p;n gpm, Hourly [.0405 — Average ACCA Manual S System equipment selection will be made using the fdlowing Manual S derived values. Summer Outdoor 93 °F Summer Wet Bulb 77°F Summer Indoor 75 °F Summer Design Grains 50 Winter Outdoor 32 °F Winter Indoor 70 °F Sensible Coding 40,633 Btuh Latent Coding 7,329 Btuh Required Coding Airflow 1,847 CFM Sensible Heating 36,759 Btuh Required Heaing Airflow 477 CFM All calculations are based upon approved hvac industry standards and procedures, and comply with all local, state and federal code requirements. All computed results are Estimates. Product provided by Energy Design Systems and Idea Tree A19R CERTIFIEDTM www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3685248 Date: 5/17/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: 25HCB348A30 Indoor Unit Model Number: FX4DN(B,F)049 Manufacturer: CARRIER AIR CONDITIONING Trade /Brand name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air - Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 47500 EER Rating (Cooling): 12.20 SEER Rating (Cooling): 14.50 Heating Capacity(Btuh) @ 47 F: 48000 Region IV HSPF Rating (Heating): 8.70 Heating Capacity(Btuh) @ 17 F: 29800 Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION UM, The information for the model cited on this certificate can be verified at www.ahridirectary.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on Air - Conditioning, Heating, which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ■� � and Refrigeration Institute ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129817329348677628