Loading...
Permit Mech 2072 George St 2012 `I A CITY OF ATLANTIC BEACH ra -. ) 800 SEMINOLE ROAD , ='x ATLANTIC BEACH, FL 32233 m.\ \ , INSPECTION PHONE LINE 247 -5814 � Ii Application Number 12- 00000634 Date 5/23/12 Property Address 2072 GEORGE ST Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 2 cu 2 ahu Owner Contractor CITY OF ATLANTIC BEACH B & G REFRIGERATION 800 SEMINOLE RD 3230 KLINE RD. ATLANTIC BEACH FL 322335428 JACKSONVILLE FL 32246 (904) 620 -0081 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 143.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 11/19/12 Other Fees STATE MECH DCA SURCHARGE 2.15 STATE MECH DBPR SURCHARGE 2.15 Fee summary Charged Paid Credited Due Permit Fee Total 143.00 143.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.30 4.30 .00 .00 Grand Total 147.30 147.30 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: Q KVSIPJ, pi,;rk sa,19, l , Pf P S;. PERMIT # PROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# yLA "5 \30'1 Air Conditioning: Unit Quantity a Tons Per Unit 3 REQUIRED Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: 'ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read his application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified rr not. The permit does not give authority to violate the provisions of NOLO') other state or local law regulation construction or the performance of construction. 'roperty Owners Name Q� V � tO .I'1\'% C `� Q;U Phone Number Q .D1.0 • c vlechanical Company 1 fie- 9 P,t (�*11C eb ) \ \t Office Phonegba.19ap •OCt Faxgt �tOau•W5 J i o. Address: 3.97 o y me City i al State F'1 Zip i3 L o .icense Holder (Print): le \ 11 I. 1 " , State Certification/Registration # C►�C l R l )1 035 Votarized Signature of License Holder' r � � ` ' / J P � G 7c ecll. t.4 i ■ ':'''' STEPHANEY STRANAN S orn an. ubscribed befor t� day of ,�t 20�2-- 4 • 1 c . Notary Public - State of Flotilla /� w r y comm Expires Apr 12.20.S nature of Notary Publi 1✓/ i / ,i _� A I •;; ' - Commission 1 EE 72055 i� COMtERCIAL LOAD CALCULATIONS Manual N Air Conditioning Contractors of America For: Name Donner Park Phone Address 2072 George St. City Atlantic Beach State & Zip FL By: Contractor Energy Design Systems, Inc. Phone (904)268 -3670 Address 12132 Weatherwood Estates Dr. W. City Jacksonville State & Zip FL, 32223 COOLING LOAD 1. DESIGN CONDITIONS Time of Day 3 PM Dly Range 19 Latitude 30 a.Inside db 72 RH 50 b.Outside db 94 wb 77 Grains 49 Otsid db @ 3pm 94 - TOD corr - inside db 72 Equals 22 T.D. Daily Range Factor= M 2. SOLAR RADIATION HEAT GAIN THROUGH GLASS COOLING LOAD Exposure Shading / NOTES Sq. Ft. SolrFactr GlasFactr Sensible N 60 X 19 X 0.7 = 798 NE X 38 X 0.7 = E 56 X !.DD X u./ = 2195 SE X 57 X 0.7 = 6 60 X 43 X u./ = 2016 SW X 88 X 0.7 = W 15 X tai X U.7 = 851 NW X 39 X 0.7 = 3. TRANSMISSION GAINS Equiv or Exposure db Sq. Ft. U Factor Temp Diff Glass 191 X 0.8 X 22 = 3362 N 700 X 0.09 X 22 = 1386 NE X 0.09 X 26 = ? . 370 X 0.09 X 31 = 1032 Walls SE X 0.09 X 33 = S 700 X 0.09 X 41 = 2583 SW X 0.09 X 47 = W 370 X 0.09 X 43 = 1432 NW X 0.09 X 28 = Doors 62 X 0.58 X 18 = 642 Partition X 0.05 X 1.z = RA Clng X 0.09 X 22 = Roof/Clng 2142 X U.Un X 5) = 6105 Floors 214 X X 22 = X X = Use Table 9a to Determine the Temp. Dif. Across an RA Ceiling PAGE TWO 4. INTERNAL HEAT GAIN Latent a. OCCUPANTS Number Sensible Latent 20 X 230 = 4600 X 20 X 170 = 3400 X = b. Lights & Others NOTE:Use 60% of installed watts for lights in RETURN AIR CEILING Watts Incandescnt X 3.4 = Flourescent 2500 X 4.1 = 10250 HP Motors Btuh Usg Ftr X = X= Appliances Other 5. INFILTRATION Ft3 /Min db Temp Dif 70 X 22 X 1.1 = 1694 Grains Diff 70 X 49 X 0.68 = 2332 6. SUBTOTALS LOADS & SPACE LOADS 38945 5732 7. DUCT HEAT GAIN Gain Line 6 Factor Sensible 0.1 X 38945 = 8. ROOM, SPACE OR DESIGN LOAD Add Duct gain (7) to Subtotal (6) 38945 9. VENTILATION Ft3 /Min db Temp Dif 400 X 22 X 1.1 = 9680 Grains Diff 400 X 49 X 0.68 = 13328 PAGE THREE 10. RETURN AIR LOAD FROM LIGHTING AND ROOF NOTE: Use 40% of watts for lights recessed in a return air ceiling Incandescent X 3.4 = Flourescent X 4.1 = NOTE: Use 100% fo the roof load for return air ceilings (Roof Load) Sq. Ft. U Factor ETD* X 0.09X = *(ETD correction based on plenum temp.) 11. TOTAL SENSIBLE LOAD ON EQUIPMENT (Btuh) = 48625 TOTAL LATENT LOAD ON EQUIPMENT (Btuh) 19060 12. TOTAL COOLING LOAD ON EQUIPMENT (Btuh) 1 67685 1 (Tons) 5.64 PAGE FOUR HEATING LOAD 13. DESIGN LOADS Inside db Outside db b Difference /2 - 32 = 40 14. TRANSMISSION LOSSES HEATING LOAD db Exp. Sq. Ft. Factor Temp Diff Heating Load Windows 891 x 1.13 x 40 = 40273 x x = 370 x 0.09 x 40 = 1332 Walls 700 x 0.09 x 40 = 2520 x 0.09 x = 370 x 0.09 x 40 = 1332 x 0.09 x = Roof/ 2142 x 0.05 x 40 = 4284 Ceiling x u.uJ x = x x = Floor 214 x u.81 x 40 = 6934 Other x x = x x = 15. INFILTRATION db Ft3 /Min Temp Diff 105 X 40 X 1.1 = 4620 16. SUBTOTAL HEATING LOAD FOR SPACE 61295 17. DUCT HEATING LOSS Loss Line 14 Factor Subtotal 0.15 X 56675 = 8501 18. VENTILATION db Ft3 /Min Temp Diff 400 X 40 X 1.1 = 17600 19. HUMIDIFICATION LOAD Inside RH Desired ( ) Max ( ) Ft3 /Min Btu /Hr / 100 X = (water) (air) gal /day Ft3 /Min X / 100 = 20. TOTAL HEATING LOAD ON EQUIPMENT (Btuh) 1 87396 I (Tons) 7.28 Energy Design Systems, Inc. 12132 Weatherwood Estates Dr. W. Jacksonville, FL 32223 (904) 268 -3670