Loading...
THRESHOLD INSP REPORT 2012 RENOVATION 985 ATLANTIC BLVD 2012 F Ellis&Assin, 4 Geohnical ■ Materials Testing ■ Environmental rnte grated Engineering Services since 1970 ' f t ^ f3{ td t, t ILA :Fitness .international, LL ' i 'Jacksonville Atlantic Beach Threshold Inspection Report (E&A Project #3 791-0003) May 2012 LAIFITNESSi Fr. E111s&Assaeiatesw.. L7i Geotechnical • Materialsting • Envrronmental s�w�ic t,anc trvcar�sEww�sFwv,css integrated Engineering Services sine*1970 LA Fitness - Atlantic Beach THRESHOLD INSPECTION REPORT NO. 002 Job No.: 3791-0003 Date: 5/31/2012 Job Location: I 985 Atlantic Blvd. Weather: Rainy Client: LA Fitness International,LLC Contractor: Impact Construction The following threshold items were inspected on this date: Component: Slab on Grade Elements: Embedment Holes for reinforcement steel embedded into Existing slab. Location: Slab near G-10 Noted deviations,or deficiencies,etc.: Checked all the holes. All holes were over 6"deep. E&A Representative: Raoaa F.Essa ommunicated to: Jerry Kin BKE Representative:. [Representing: E&A BKE 7064 Davis Creek Road 1334 Walnut Street Jacksonville,FL 32256 Jacksonville,FL 32206 Phone:(904)880-0960 Phone:(904)356-8520 Fax:(904)880-0970 Fax:(904)356-8524 I Ellis$�ASSOCI LKIeln ker Baker Klein 11 II1Qe1"lll�I L. [:R!NG.,, STRU L r I a.-\ Edi U SERVICES Geotecnr}ical ■ Materials bstrg ■ &Vrorirrierital Integrated Engineering Services since 1970 June 15, 2012 Mr. Michael Griffin City of Atlantic Beach 800 Seminole Road Atlantic Beach,Florida 32233 Subject: Threshold Inspection-Monthly Report No. 1 LA Fitness Atlantic Beach Jacksonville, Florida Project No. 3791-0003 Permit No. B12-0066 Dear Mr. Griffin Ellis & Associates, Inc. (E&A) along with Baker Klein Engineering, P. L. is pleased to present this threshold Inspection Monthly Report No. 1 for the LA Fitness Atlantic Beach project located on 985 Atlantic Boulevard in Jacksonville, Florida. Our Services on this project were performed in general ,accordance with availablero'ect documents p prepared by Cuhaei & Peterson Ar hi Engineers (Planners, dated January 27, 2012. In general the work activities performed during the period of May 1 through May 31, 2012 includes Cast In-Place concrete inspections for slab on grade. We are retained to perform threshold inspection services on this project on "as-needed" basis (i.e. our representatives are not present on site at all times during the construction activities). The threshold inspections performed by our representatives typically include periodic observations of construction activities for substantial compliance with the project documents. This Letter addresses Threshold inspection Reports No. 1 and 2 performed during the period of May 1 through May 31, 2012. The Construction Materials Testing (CMT) reports were reviewed and no deficiencies were noted. The I include concrete testing and in-place density testing. These reports are available, if requested. Relevant items pertaining to the structure that have been inspected by our personnel and appear to deviate from available contract documents that have been approved by the Engineer of Record(EOR)are listed in the threshold inspection reports, and in the Non-Compliance Record. The non-compliant items will remain on the Non-Compliance Record until written response is submitted by the EOR. Responses properly issued by the EOR and received by this office will be incorporated into that period's Threshold Progress Report. E&A BKE 7064 Davis Creek Road 1334 Walnut Street *' Jacksonville,FL 32256 Jacksonville,FL 32206 Phone:(904)880-0960 Phone:(904)356-8520 Fax:(904)880-0970 Fax:(904)356-8524 Ellis Ussaciatesm.. LNGINEERING�el BalcerTl�leia� Engi�lee�~its::0 +----- --- , PUCTUTn'Al_E,C":Eti_RING;ER`s"ICES ��. Geotc-Oncal ■ Materials Tast r,g a EnvirorzrTiental Integrated Engineering Services since 1970 We appreciate this opportunity to be of service on this project. Should you have any questions or comments regarding this report,please contact us. Respectfully Submittc?, Baker Klein Eagineerin P.L. Christopher l(. Sube,P.E. Special Inspector No. 7023857 Licensed,Florida 38290 Distribution: File (2 Copies) LA Fitness International,LLC (1 Copy) Attn: Mr.Robert H. Stephens 4350 Georgetown Square, Suite 709 Atlanta, GA. 30338 City Of Atlantic Beach (1 Copy) Attn: Mr. Michael Griffin City of Atlantic Beach 800 Seminole Road Atlantic Beach, Florida 32233 Cuhaci& Peterson (1 Copy) Attn: Tony Laudani 1925 Prospect Avenue Orlando,FL 32814 Impact Construction (1 Copy) Attn: Mr. Jerry King 7525 E. 39th Street- Suite 1100 Indianapolis, IN 46226-5157 McElory Engingeering,LLC. (1 Copy) Attn: Mr. Craig E. McElory, P.E. 1925 Prospect Avenue Orlando, FL 32814 E&A BKE 7064 Davis Creek Road 1334 Walnut Street Jacksonville,FL 32256 Jacksonville,FL 32206 Phone:(904)880-0960 Phone:(904)356-8520 Fax:(904)880-0970 Fax:(904)356-8524 TABLE OF CONTENTS APPENDIX A: Threshold Inspection Reports p ► APPENDIX B: Non-Compliance Record APPENDIX C: Photographs of the Subject Project OR a�* APPENDIX A Threshold Inspection Reports _ E_ 111MUsOCiates �/�keh Baker Klein Engineering, PL. ��� Kleiii STRUCrUaA� E:iGstdEERRdG SERVES Geotechnical • Materials Testing • �Env�ronmental fNCANORiNG, Integrated Engineering Services since 1970 LA Fitness - Atlantic Beach THRESHOLD INSPECTION REPORT NO. 001 Job No.: 3791-0003 Date: 5/30/2012 Job Location: 985 Atlantic Blvd. Weather: Clear Client: LA Fitness International,LLC Contractor: Impact Construction F llowing threshold items were inspected on this date: nent: Slab on Grade Elements: Horizontal Reinforcement,vapor barrier,spacing,lap,and clearance Location: E.5-12 to D-12 to E.5-8 to D-8 Noted deviations,or deficiencies,etc.: The items listed above have been installed as shown on the detail drawings and appear to be in general compliance with the project documents. The embedment depth of the rebar tying into the existing slab was not checked since the rebars were already installed and epoxied. E& R esentative: Raoaa F.Essa Id to: J Kin Resentatia resentin : E&A BKE 7064 Davis Creek Road 1334 Walnut Street Jacksonville,FL 32256 Jacksonville,FL 32206 Phone:(904)880-0960 Phone:(904)356-8520 Fax:(904)880-0970 Fax:(904)356-8524 am �Blker Baker Klein Engineering, PL. MIE111MAssociatesw. eulGeotechnical a Materials Testing ■ Environmentalura cr�aan�eraGNFw ��Sayses iNCANIMN""r Integrated Engineering Servkes since 1970 LA Fitness - Atlantic Beach THRESHOLD INSPECTION REPORT NO. 002 Job No.: 3791-0003 Date: 5/31/2012 Job Location: 985 Atlantic Blvd. Weather: Rainy Client: LA Fitness International,LLC Contractor: Impact Construction The following threshold items were inspected on this date: Component: Slab on Grade Elements: Embedment Holes for reinforcement steel embedded into Existing slab. Location: Slab near G-10 Noted deviations,or deficiencies,etc.: Checked all the holes. All holes were over 6"deep. E&A Representative: Raoaa F. Essa ommunicat'd to:Jerry Kin BKE Representative:. resenting: E&A BKE 7064 Davis Creek Road 1334 Walnut Street Jacksonville,FL 32256 Jacksonville,FL 32206 Phone:(904)880-0960 Phone:(904)356-8520 , , Fax:(904)880-0970 Fax:(904)356-8524 APPENDIX B Non-Compliance Record Mw F I T IT o � y a � 0 y a o C LL A Li M Q •; c a G o i+ M : c �. g o c yz a az a 0 Am z APPENDIX C Photographs of the Subject Project LA Fitness—Atlantic Beach 4,m Photograph 1 -May 30, Slab on Grade. J Photograph 2-May 30, Slab on Grade May Photos.doc May 2012 w� Ellis& inc. Geotechnical ■ Materials Testing ■ Environmental Integrated Engineering Services since 1970 a 7 f t 6 ' I F �orporate Headquarters/7064 Davis Creek Road /Jacksonville, FL 32256/(904) $80-0960 I Brunswick Branch/227 Rose Drive/Brunswick,Cry 31520/(912)279-0085 www e1lispssoc com Serving Northeast& Central Florida,, 4nd;Sbutheast Georgia since 1970 L::�Aj E111sUssoclatesw. Geotechnical a Materials Testing a Environmental integrated Engineering Services since 1974 May 23, 2012 Mr.Michael Griffin City of Atlantic Beach 800 Seminole Road Atlantic Beach,Florida 32233 Dear Mr. Griffin: Re: LA Fitness—Atlantic Beach Atlantic Beach,Florida Permit No.B 12-0066 Please be advised that the following special inspectors and delegates have been assigned to perform threshold inspections at the captioned property: • Mr. Christopher R. Sube,P.E. Baker Klein Engineering,Inc. Florida Special Inspector No.7023857,Florida P.E.No. 58290 1334 Walnut Street Jacksonville,Florida 32206 "7 (904)356-8520—Phone csube@bkeiax.com—Email I 1/1-1 • Raoaa F.Essa,E.L,Florida E.LT No. 1100012644 Project Engineer/Threshold Inspector Delegate Ellis&Associates, Inc. 7064 Davis Creek Road Jacksonville,Florida 32256 904-880-0960—Phone `� Lt r.essa o,ellisassoc.com—Email • Scott Wallingford,Florida Standard Inspection No.BN6297 Senior Inspector/Threshold Inspector Delegate h l 7064 Davis Creek Road Jacksonville,Florida 32256 904-886-5113—Phone s.wallin fg ordgellisassoc.com-Email Sincerely, N_ O et-'4 Nemer(Nick)Y.Oweis,P.E. Senior Project Manager Cc: Mr. Christopher R. Sube,P.E. 7064 Davis Greek Road Jacksonvil[10A 32256 p:944-880-0960 f:904-880-0970 Serving the Southeast since 1970. Offices: J sonville,FL and Brunswick,GA ellksassoc�