Permit Mech 2347 Seminole Reach Ct 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00000640 Date 5/23/12
Property Address . . . . . . 2347 SEMINOLE REACH CT
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 4000
----------------------------------------------------------------------------
Application desc
CHANGE OUT 2 TON SYSTEM 3847132
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
BOUDREAUX, LISABETH C FLORIDA HOME DBA ARS
2347 SEMINOLE REACH DR 4211 EMERSON ST
ATLANTIC BEACH FL 322335967 DEFUNIAK SPRINGS FL 32435
(904) 777-4300
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . . CHANGE OUT 2 TON SYSTEM
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 11/19/12
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: C�Z3-(-2 6em: t 1) r I PERMIT#la�A
PROJECTVALUE$ l000
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating_
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit ARI# 13?;
—C - REQUIRED
Heat: Unit Quantity I BTU's Per Unit ;xt cc)o Seer Ratin
Duct Systems: Total CFM g—i-'!?—
REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces
Reffigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have 7ead
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name—L�. ou otre- ck,)K PhoneNumber
Mechanical Company Flyr,ja 4ofn
—Office Phone Y6 Fax 22 9-9 57 2
Co. Address: L4- city-aad,50n "I len State-&-Zip 3L-2�0-u
License Holder (Print): - L 0 State Certification/Registration# C�M C- 1 61�9 q-37
Notarized Signature of License Holder
AROLYN TURNER 20 /2—
My COMMISSION#EE061381 Signature of Notary Public
Sworn and subscribed before day o
�Ky P(,,1,
C f
Al,A', EXPIRES May 16,2015
1,
(407)398-0153
Floridalloteryservice.com
CERTIFIEDTM
L www.ahridireetory.org 'A
Certificate of Product Ratin2.s
AHRI Certified Reference Number: 3847132 Date: 5/23/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 13PJL24JA01
Indoor Unit Model Number: RHSL-HM2417+RCSL-H*2417
Manufacturer: RHEEM MANUFACTURING COMPANY
Trade/Brand name: SURE
Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 24400*
EER Rating (Cooling): 10.50*
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 22800
Region IV HSPF Rating (Heating): 7.70
Heating Capacity(Btuh)@ 17 F: 13600
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibil for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s ity
unauthorized alteration of data listed on this CertJificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridire),or the
TERMS AND CONDITIONS ctory.org.
This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at ahridirectory.org,
click on"Verify Certificate"link and enter the AHRI CerUfled Reference www. A 1"101 Air-Conditioning,Heating,
Number and the date on
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. APOU On ILI and Refrigeration Institute
02012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129822558094803093
Quit? - 105/22/12 15: 06:18 1 CALL SLIPS I Last CS #
-------------------------------------------- JCS# 87079
INSaimtee:#BO007643-001 . 007643 COD Only: y ------------------------------------
UDREAUX, LIZ JSTATUS:1REC`V1 1$ I#Eq:
- ---------------
Addr: 2347 SEMINOLE REACH CRT Dys: Hrs:
ATLANTIC BEACH FL � 32233 S.Notes?N BPO: Contr Eq:A&H
Phone: (904) 923-6133 . Contract ID: C4354 Type: HSP
lAlt: BOUDREAUX, LIZ C.Dates:03/01/2012 - 02/28/2013
-------------------------------------------- Cr. Hold:N Zone
jJob #: -------------------------------------
----------------- - - - ---- - ------Service-Job #:---------- - P.O.# 1-2122659852. 1
jContaQ ------- --- -- ------------------------
Prob Co . PhOne: (904) 249-9196-Source:INV
e: AOR. *ADD ON REPLACEMENT Equip Sel:
Call Instr. :*HD* ST#6365 L#1-2122659852
:2T RHEEM BRIAN WILSON $4000. 00
PRT05/22/12 Prty: 1. OverT:N.
Site Instr. Sch? ReSch: .
------------- Date: 05/23/12.
TakenByCOST 1 :2005 2ton trane Time: 8:00.
Tech: 712.S:
1RECVI MATERIAL C H A R G E S
007643-001 BOUDREAUX, LIZ C.S.#: 87079
COnt Type: HSP Spec Notes? N
Page: 1
PO#/TRj KEY DESCRIPTION MODEL,SERIAL# of 2 -----
------------------------------------------- JQTY ISRILISTCOSTJ PRICE SALE
16321. .13PJL24AO1 ------------------------------------
16321. -RHSHLM2417J 1.R 739. 00o.
16321. RXBH-1724BO5J 1.R 308. 000.
16322. .16X20 FILTER RAC 1.R 45. 0000.
1.R 57.8400.
------ ------
+ ------------------------------- - ---- ------------<<
Name/TRl: ITot Cost: 1149.84 ITot+Sale: .00 ITot Pg: . 00
Name/TR2:
Name/TR3: RATE TYPE: DEFAULT. Elim mat Chrge?N. MATL: .00.
Name/TR4 : POst to Site Stock? IUSE Tax Reg: $
DesignStar Load Calculation
Resufts are intended fbr use with Rheem heating and cooling systems only
TIm New Dogtoe*I Corrtion-
Location:
Street Address 2347 seminde reach crt DUVAL, FL 32233
Latitude, Longitude 30.3375',-81.7686-
House Square Footage: 1000 sq.it
Name: Liz Boudreaux
Phone: 904-923-6133
Email: example@mail.com
Outdoor Heating Cooling
Dry bulb(*F) 32 93
Daily range M
Relative humidity 50%
Moisture difference 53
Indoor Heating Cooling
Indoor temperature(*F) 70 75
Design temperature difference(*F) 38 18
Area
Wall Btuh % of load
Floor 2416 10A
Ceiling 9310 40
Windows 2014 8.7
Infiltration 2736 11.8
4665 20.1
System Efficiency Loss 2114 9.1
Total:
Heating Loads
23,255 BTU/hr
Ceiling
System Efficiency Loss
Floor
V,
Wall
Windows
Infiltration
MEK22 WITI
Area Btuh % of load
wall 1144 4.9
Ceiling 954 4.1
Windows 12569 53.9
Sensible Infiltration 1657 7.1
Latent Infiltraficn 3017 12.9
System Efficiency Gain 1934 8.3
Internal 112.2 4.8
Sensible People Load 460 2
Latent People Load 460 2
Total: 23317
Sensible load 19841
Latent load 3477
SHR 0.85
Capacity at.75 SHR 2.20 Tons
Cooling Loads
23,317 BTU/hr
Sens ible People Load
Latent People Load
Ceiling
Internal
Wall
Sensible Infiltrati
Windows
System Efficiency:
Latent Infiltration i
1 INNEIM4UW111-Irs
20000 AED Graph
15000
M
10000
5000
0
8am 9am 10am I I lam 12pm Ipm 2pm 3pm 4pm 5pm 6pm 7pm 8pm
Hourly Loads _=.�verage
summer outdoor System equipment selection will be made using the following Manual S derived values.
Summer Wet Bulb 93'F
Summer Indoor 77'F
Summer Design Grains 75'F
Winter Outdoor 50%
Winter Indoor 32'F
Sensible Cooling 70*F
Latent Cooling 19,841 Stuh
Required Cooling Airffow 3,477 Btuh
Sensible Heating 902 CFM
Required Heaing Airflow 23,255 Btuh
302 CFM
All calculations are based upon approved hvac industry standards and procedures, and comply with all local,state and
federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea
Tree