Loading...
Permit Mech 42 11th St 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00000629 Date 5/23/12 Property Address . . . . . . 42 11TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc CHANGE OUT 2 . 5 TON SYSTEM ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ TUCKER ADELAIDE R TRUST DONOVAN HEATING & AIR 42 11TH ST 31S SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322335700 JAX BEACH FL 322SO (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . CHANGE OUT 2 . S TON SYSTEM Permit Fee . . . . 9S . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/19/12 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. M-ECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 JOB ADDRFm: �k Ph(904)247-5826 Fax(904)247-5g45 PERMFr# PROJECT VAL UE NEW AIR CONDITIONING&HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat Unit Quantity BTUs Per Unit Seer Ly Duct Systems: Total CFM REQUMM REPLACEMENT AIR CONDITIONING&]HEATING SYSTEM INSTAL AT]FO F J4 � Ll ARIft Air Conditioning: Unit Quantity Tons Per Unit 15 RO Heat Unit Quantity BTU's Per Unit_3Q.20_0 Seer Rating I'- Duct Systems: Total CFM 5 REQUMED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requim 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression System Quantity (Requires 3 sets of plans) FMPLACES MISCELLANEOUS: PreMricated,Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTUs Elevatori��a�tors ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets PUMPS #Vented Wall Furnaces Reffigerator Condenser BM7s Water Heaters Solar Collection systems Tanks*11ons) Wells OTIRER: Perruft beconws void if work does not commence,within a slK nionth period or work is suspended or abandoned for six months.I heli-eby certify '1have,=ead this application and lmow the 90100 to be true and corrat All provisions of laws and ordinances govemiqg this walk will be complied with Whether Vecified X DDL 11ne pmnit does not give autborhy to Violate the provisions of any other state or local law regulation conshuction or the perkwmance ofconstruction. Droperty Owners Name (XiAe- ­1-�—,Ae-yl- q7 mj� Phone Number—,2% Wechanical.Company Tannove,ii j- y4i o- —Office,Phone S31 1-3*7 K DF0 1A 1-31 9Y- �o.Address: 791 S_ 6;tfe- _s, _ city ()&44 Ge4ck stow C zip 3 .,icense Holder OVInt): Ommovr-n -State Certification/Reebstaition,# 161 VoW*,ed Sknaallm qfLkense HoMer 2,, �2a-k�� Sworn and 41�ibed before meta dayof a!j 201?_ Signature,of Notary Public k* Notary Public State oOf Florida Timothy Lee HUghOs My Commisesion EE 186278 Ex:pirles 04/03/2016 Job: oata. WWr 22,2012 wdghtSOft Project SummarY Jay: Aaron Thacker Entim House Donovan Heat& Air 350 phum,,904-241-37M Far,904-?AI-3745 rnmall:*aronQdGftGVsMc,C0M web:www.DQnoVsnAC,C0M M Rh fmg S,jg0K9anV1k aWh,FL 32 For, Adelaide Tucker 40 11th St,Atlantic:Beach, Fl-32233 Notes: Weather: Jacksonville Mayport Naval, FL, US wintgr Design Conditions Summer Design condiflons Outside db 95 OF Outside db 39 OF 75 OF Inside db 70 OF Inside db 20 OF Design TD 31 "F D ign Dail ran e L Rel ive idity 50 % moisture differefice 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11282 Stuh Structure 15282 Btuh 3353 Btuh Ducts 4753 Stuh Ducts vent(0 cfm) 0 Stuh Central vent(0 cfm) 0 Btuh Central 0 Btuh Humidification 0 Btuh Blower piping 0 Btuh Use mantifacturer's data n Equipment load 14636 Btuh Rate/swing multiplier 1.00 Infiltration Equipment sensible load 20015 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2253 Btuh Fireplaces 0 Structure 1014 Stuh Ducts 0 Btuh "Non co I' Central vent(0 cfm) 3267 Stuh I f,2 1322 0 Ing Equipment latent load Area 1324 Valum ft3) 11916 11916 Equipment total load 23282 Btuh Air chanpes1hour 0.45 o.23 capacity at 0.70 SH R 2A ton Equiv.AVF(cfm) 89 46 Req. total Heating Equipment summary Cooling Equipment Summary make Tempstar Make Tempstar Trade 13 SEER N SERIES R410A HP Trade 13 SEER N SERIES R410A HP Model N41-1330A(G)KE' Cond N4H33OA(G)KE* C0711 FEM4PV*A* AHRI ref nc3718047 AHRI ref nc3716047 11.0 EER, 13 SEER Effic, 7.7 HSPF Efficiency H=;'ng Aput Sensible cooling 21000 Btuh 3MM Btuh @ 47OF Latent cooling 9000 Stuh Heating otAput 30000 Stuh Temperature rise 27 OF Total cooling Actual air flaw 1000 cfm Actual air flbw 1000 cfm Air flow factor 0.068 dm/Btuh Air flow factor 0.050 cfrnfBtuh Static pressure 0 in H20 Static pressure 0 in H20 0.86 Load sensible heat ratio Space thermostat Calculations approved by ACCA to meet all requirements of Mmual J 8th Ed, 20ig-May-21 00:30!20 A&+wrightsaft' Ftlght-SulkeS Univatcal 8,0,24 RBU05995 Page I C:JUaer"J0wher%D0CUMantskwdqhtqof1 HVAGN509us 2 5 tan,ruP carc-mia Front Dom faces: E CERTIFIEDTM www.ahridirectory.org -A Certificate of Product Ratings AHRI Certified Reference Number: 3718047 Date: 5/22/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: N4H33OA(G)KE* Indoor Unit Model Number: FEM4P30**A* Manufacturer: TEMPSTAR Trade/Brand name: 13 SEER N SERIES R410A HP Manufacturer responsible for the rating of this system combination is TEMPSTAR Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 30000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F 30000 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh) @ 17 F: 18300 Ratings followed by an asterisk(*)indicate a Voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "IMP, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on klu no ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129821847400767980