Permit Mech 5403 Fleet Landing 2012 CITY OF ATLANTIC BEACH ,; s) 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 N Application Number . . . . . 12-00000627 Date 5/23/12 Property Address . . . . . . 1 FLEET LANDING BLVD MAIN Tenant nbr, name . . . . . . UNIT 5403 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------------------------------------ Application desc 1 cu 1 ahu ------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC FLEET LANDING 6491 POWERS AVENUE 1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 32233 (904) 724-7211 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/19/12 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB AnnREss. AA / \ ' , .1- e LQ n d c 6(v . rt c P�c L PERMIT# 3zz3-7 PROJECT VALUE $ Co Co NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Unit Quantity ARI# 3��2 2� Air Conditioning: Q y Tons Per Unit 3.S REQUIRED Heat: Unit Quantity _ BTU's Per Unit_pro, oer, Seer Rating /`3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty, Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) / l Wells OTHER: Vit Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number hoc-!-Z YG _9gcc Mechanical Company bav i GYc,y gQ lt� Office Phone -7q I Fax Co. Address: 6c(4 ( awey s City- t r k5dnv,1It State Zip 322..1 License Holde>C4#f & G r(cj� State ertification/Registration#_C ?I C.�5�r& Notarize` '!wnse Holder j Mr comm.Evfts': =. Sworn and subscribed before me this L 2 "rday of r 20� : JMRry 10,2014 c N:. Ho,ooesoela ; Signature of Notary Public Q -SV4 .,, c' ' Oma: . }. Right J® Mobile Report Job: w� htso Date: 5/22/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5403,Atlantic Beach, FL 32233 Phone:904-246-9900 Fax: 904-246-9455 .-Pesign Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange (°F) - 17 ( M ) Method Simplified Wet bulb(T) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh %of load Walls 17.3 25389 57.2 hilitrzbv, Glazing 19.8 4262 9.6 Doors 13.5 433 1.0 Rms Ceilings 1.7 2438 5.5 Floors 6.2 8963 20.2 Infiltration 2.1 2869 6.5 Ducts 0 0 VWIs Cdlirgs Piping 0 0 Ch Humidification 0 0 oaarg Ventilation 0 0 Adjustments 0 Total 44354 100.0 • • • Component Btuh/ft2 Btuh %of load Walls 8.7 12841 44.3 IrtenChins Glazing 45.1 9700 33.5 lrliftrtcn Doors 11.4 367 1.3 Calings Ceilings 2.6 3720 12.8 Floors 0 0 0 Ndl Ctha. Infiltration 0.5 691 2.4 Ducts 0 0 Ventilation 0 0 Internal gains 1660 5.7 Blower 0 At Adjustments p 0 aaarg Total 1 289791 100.0 Latent Cooling Load = 1784 Btuh Overall U-value=0.184 Btuh/ft2-°F Data entries checked. •±a writ hts 2012-May-22 07:27:30 Right-Suited Universal 2012 12.0.04 Right J®Mobile Page 1 C:\IMNDOWS\TEMP\wstmp\ea71c3f8-2329-46da-b23a-3716a466e16e.rup Calc=MJ8 Front Door faces: N wrightroft. Project Summary Job: Entire House Date: 5/22/2012 David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5403,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 44354 Btuh Structure 28979 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 44354 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28979 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1784 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ftp 1438 1438 Equipment latent load 1784 Btuh Molume (ftp 10066 10066 Air changes/hour 0.45 0.23 Equipment total load 30763 Btuh Equiv.AVF (cfm) 75 39 Req.total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Trade Model ARUF Cond GSX AHRI ref no. Coil AHRI ref no. Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1319 cfm Actual air flow 1319 cfm Air flow factor 0.030 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A-: ..Jy�-. wirli htSOft 2012-May-22 07:27:30 "1' � Right-Suite®Universal 2012 12.0.04 Right J®Mobile C:\WINDOWS\TEMP\wstmp\ea71c3f8-2329-46da-b23a-3716a466e16e.rup Calc=MJ8 Front Doorfaces: N Page 1 wrightsoit' Right-J® Worksheet Job: Entire House Date: 5/22/2012 David Gray Heating and Air, INC. By: 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... 1 Room name Entire House First Floor 2 Exposed wall 190.8 ft 3 Room height 9.0 ft 9.0 ft 190.8 ft heattcool 4 Room dimensions 5 Room area 1438.0 ft' 1438.0 ft'1.0 x 1438.0 ft Ty Construction U-value Or HTM Area (ft') I Load I Area (ft') I Load number (Btuh/ft'-°F) I (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 15A Ooc 2 0.584 ne 17.63 9.11 612 597 10524 5438 612 597 10524 5438 1D-clow 0.570 ne'' 19.72 46.75 15 0 296 701 15 0 296 701 15A-Ooc-2 0.584 se 16.77 8.21 234 171 2867 1404 234 171 2867 1404 1OB-w 0.600 se 20.76 26.29 18 0 374 473 18 0 374 473 11 1 D-clow 0.570 se 19.72 49.18 45 0 887 2213 45 0 887 2218 Vf/ 15A-Ooc-2 0.584 s 14.54 5.89 25 11 164 66 25 11' 164 66 L---G 1D-clow 0!570 -s 19.72 25.16 14 0 279 356 14 0 279 356 15A-Ooc-2 0.584 sw 17.32 8.78 594 517 8952 4541 594 517 8952 4541 1 D-c2ow 0.570 sw 19.72 49.18 45 0 887 2213 45 0 887 2213 11 DO 0.390 sw 13.49 11.43 32 32 433 367 32 32 433 367 15A-Ooc-2 0.584 nw 16.57 8.00 252 174 2882 1392 252 174' 2882 1392 1D-c2ow 0.570 nw 19.72 46.75 30 0 592 1403 30 0 592 1403 1 D-c2owd 0.570, my _ 19.72 46.75 48 0 947 2244 48 0 947 2244 C 16B-19ad 0.049 1.70 2.59 1438 1438 2438 3720 1438 1438 2438 3720 F 22A-cph 1.358 46.99 0.00" 1438 191 8963 0 1438 191 8963 0 6 c)AED excursion 196 96 Envelope loss/gain 41485 26629 41485 26629 12 a) Infiltration 2869 691 2869 691 b) Room ventilation 0 01 1 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 1200 1200 Subtotal(lines 6 to 13) 44354 28979 44354 28979 Less external load 0 0 0 0 Less transfer 0 0 0 0 0 0 0 0 Redistribution 14 Subtotal 44354 28979 44354 28979 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total room load i44354 Air required(cfm) ) 289791 1 1 44354 1 289791 1 1319 1 1 1319 1319 1319 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed wright1s-o Rig ht-Su ite®U niv ersal 2012 12.0.04 Right J®Mobile 2012-May-2207:27:30 C:\WINDOWS\TEMP\wstmp\ea71c3f8-2329-46da-b23a-3716a466e16e.rup Calc=MJ8 Front Doorfaces: N Page 1 - wrightsoft Component Constructions Job: Entire House Date: 5/22/2012 David Gray Heating and Air, INC. By: 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rcabinsky(Mdavidgrayonline.com Web:www.davidgrayonfine.com Licens... For: Fleet Landing 1 Fleet Landing Boulevard- Unit#5403,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 IIIIIIIIIIN Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 Elevation: 43 ft Design TD (°F) 35 75 Latitude: 30°N 16Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange (°F) - 17M 1/1etbulb(°F) _ 77 ( ) Method Simplified Wind speed(mph) 15.0 7 5 Construction quality Average Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain Walls ft2 Btuh/ft'-°F ft'-°F/Btuh Btuh/ft' Btuh Btuh/W Btuh 15A-Ooc-2:Bg wall,heavy dry or light damp soil,empty core, ne 597 0.257 0 17.6 10524 9.11 5438 concrete block wall, 10"thk se 171 0.257 0 16.8 2867 8.21 1404 s 11 0.257 0 14.5 164 5.89 66 sw 517 0.257 0 17.3 8952 8.78 4541 nw 174 0.257 0 16.6 2882 8.00 1392 all 1470 0.257 0 17.3 25389 8.73 12841 Partitions (none) Windows 1 D-c2ow:2 glazing,clr outr,air gas,wd firm mat,clr innr, 1/4"gap, ne 15 0.570 0 19.7 296 46.8 701 1/8"thk se 18 0.600 0 20.8 374 26.3 473 se 45 0.570 0 19.7 887 49.2 2213 s 14 0.570 0 19.7 279 25.2 356 sw 45 0.570 0 19.7 887 49.2 2213 nw 30 0.570 0 19.7 592 46.8 1403 nw 48 0.570 0 19.7 947 46.8 2244 all 215 0.570 0 19.8 4262 44.6 9604 Doors 11 DO:Door,wd sc type sw 32 0.390 0 13.5 433 11.4 367 Ceilings 166-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins, 1/2" 1438 0.049 19.0 1.70 2438 2.59 3720 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet flr fnsh 191 1.358 0 47.0 8963 0 0 - -1"- wrightsoftm Right-Suite®Universal 2012 12.0.04 Right J®Mobile 2012-May-2207:27:30 '&k C:\WINDOWS\TEMP\wstmp\ea71c3f8-2329-46da-b23a-3716a466e16e.rup Calc=MJ8 Front Door faces: N Page 1 wrightsoft AED Assessment Job: Entire House Date: 5/22/2012 By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com LicensPr ... oject Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5403,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 Elevation: 43 ft Design TD(°F) 35 75 Latitude: 30°N 16Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange (°F) - 17 ( M ) Wet bulb(°F) - 77 Wind speed (mph) 15.0 7.5 HourlyGlazing Load 12, 11, 1Q 9, 8, 7, 6, 5, 4,000-- 3,000-- 2,000-- 1,000-- 0 ,3,2,1, 0 8 9 10 11 1'2- 13 14 15 16 17 18 19 20 Hour of Day FhAy / ADlin it Maximum hourly glazing load exceeds average by 31.1%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 96 Btuh (PFG - 1.3*AFG) wrightSOft Rig ht-Suitee Universal 2012 12.0.04 Right J@ Mobile 2012-May-2207:27:30 C:\WINDOWS\TEMP\wstmp\ea71c3f8-2329-46da-b23a-3716a466e16e.rup Calc=MJ8 Front Doorfaces: N Page 1