Loading...
Permit 1707 Park Terrace W (vault) CTly OF ATLAWMC RMACA ?16 0CbAW BOULEVARD 1R.71ANTI C RZACH, FLORIDA ADD UM TO BUILDING FLAK 1. Building location: _,,.1707 Park Terrace West 2. The attached plan for the above building is approved subject to meeting the following applicable* construction requirements: a. Fla i sha i�1 be continuous monolithic concrete under exterior wall,*, reinforcedd with two 5/8" deformed reinforcing rode for one--story buildinge and three 5/8" deformed reinforcing rods for twee-story buildings . R.einforcing rods shall be placed in the lower one-third of the footings, properly placerd, and fastened on metal saddles with wire. Footings shsall be six inches wider on each side than the wall. above, ;;ihali he at least eight inches thick and shall rest on f'irv. &oi.l at least twelve inches 1w. 1ow undist%.%rbW�j'_ ;;oil.. b. In hollow construction. each unit cell shall be r+einfo. eod with at laast one 80. 5 bar at all corners, poured and tamped with concrete. such .reinforcing sharp be properly tied into the: footing and spandral beam. c. All wood tuns rafters rocf construction';' Shall be sstecurel-r fasatexned to the exterior walls with approved hur*°ic ane anchors; or cl.i-os. d. Construction of nearby one-family dwellings, which are duplicates or intensely similar, shall be avoidaud. Stich similarity considers the external configuration and .*ppexranee (i.e. , root„ oat4r wall materials, 4ndow seize and design. and other '.i3cs c1soia,7teeristiva) of structures. in accord with the foregoing, similar or duplicate homes shall. not be constructed within close proximity of each other, and shall be at least 500 feet apart if any one similar dwelling res visible from any other similar dwelling. 4. Sewer service co=ectiona must be probed with c1e�sn•-.ox1.t. .rods in the presence of a City inspector. f. The final connection between the hoksse plumbing drain and the sewer service connes�-tion (at the property line) st -unt. be inspected by the City before being rovere d City Manager The undersigned hereby certified that he has read the above and understands that this addendum tAkes precedence over any ccontz details to the plans and speeif'ir_atianx and agrees o ith the intent of this addendum. By FOR OFFFICE USE oONLY D Permit #---•....................Fee$- CITY OF ATLANTIC BEACHeD Valuation .............. FLORIDA HouseD7 6 !( e,,rxc �/ e Di��-----�1.9e--------X00--------------- APPLICATION FOR BUILDING PERMIT wcc------------------­------- .. ...................... Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure described. This application is made in compliance and conformity with the Building Ordinance of the City of Atlantic Beach, Florida, and all provisions of the Laws of the State of Florida, all ordinances of the City of Atlantic Beach and all rules and regulations of the Building Department of the City of Atlantic Beach, shall be complied with, whether herein specified or not. The Contractor or Owner-Builder who has been issued a Building Permit is automatically responsible to ascertain that all sub- contractors engaged by him are duly licensed in the City of Atlantic Beach, Florida. To prevent delay or embarrasment regard- ing intermediate or final inspections it is suggested that a list of sub-contractors he submitted to this office so that licenses can be verified. 1 Date......... r .� --------------------------------------- 19. Owner J�� / / - .l-_.._.------•--•---------_-Address--•--------------------------•-••----------•----_--.-----•--Telephone No----------------------------- Architect.----------------------------------------------------------------------------------------------Address...........................................................Telephone No--------------_---_------- Contractor Builder-/.rf J--- �r� ------/ �-.-Address------------------------------------------------------------Telephone No.... ---f � r_ Sub Division --- Zone---_----------- s Lot e------7 --- /-------T `4 B etk No.---- .. Side Between-----------------------------------------------------and......................................................Sts. Valuation $ __ p_ _For what pu gse will building be used--�1-_ 'r) Type of construction_._ °�._ .. Dimensions of Building.�� �.7-... /___Dimensions of Lot./ :k_._�.�� k /. . .-........ of Footings ;U_16 g------_/---- - - ---..._... gs Size of Piers-----------------------------------Size of Si1ls__...---------------------------Greatest Sill Span in ft-----------.---------------Type Roof...................................... l T ` `-----------------------_---_--Will Building be on Solid or Filled Ground?--------..i^0--1.Z.P......... How will Building be Heated?___ _ ___________ g Size of Ceiling Joists.--I_N----�flr.r----------- Distance on Centers___________ _________________________________ Greatest Span............................................ it Size of Floor Joists----------------------------------------------- Distance on Centers.-....... __.............................. Greatest Span----------.................................. to Size of Rafters.---_----------------_----------------------------, Distance on Centers. --- ---- --------------------_- Greatest Span---------------........................... ,F APPROVED CITY OF ATLANTIC BEACH This rectangle is to represent the lot. BUILDING OFFICE Locate the building or buildings in the right position. Give distance in feet from all lot-lines and existing buildings. N O V 2 9 1977 REAR LOT LINE Two copies of plans and specifications shall be submitted with application. Inspections required. By 1. When steel is in place and ready to pour footing. 2. When steel is in place and ready to pour columns and/or lintel. /111A4T_5 a 3. When steel is in place and ready to pour beam. 4. When framing is completed. p p 5. When rough plumbing is completed,and ready to cover up. W W 6. When septic tank drain field or sewer is laid but before it is covered. q q 7. Electrical inspection by City of Jacksonville. M 8. Final inspection. Note: In case of any rejection,re-inspection MUST be called for after corrections are made. FRONT OF LOT In consideration of permit given for da ng the work as described in the above statement, we hereby agree to perform said work in accordance with the attached lan and ape ' which are a part hereof, and in accordance with the building regulations of the City of At - of Buil .. :. . n •-•• .. ----------------------------- Signature Signatureof Owner......................... ........ ........... ........ .. Address................................................................................................... f k DEPARTMENT OF BUILDING CITY OF ATLANTIC BEACH, FLORIDA3 5 4 4 PERMIT TO BUILD PERMIT NO. THIS PERMIT MUST BE POSTED ON JOB r Date_ 1IZ29 7 19 Valuation $ 52,999 Fee $ 1.42.50 This permit not valid until above fee has been paid to City Treasurer, and is subject to revocation for violation of applicable provisions of law. This is to certify that F T Tr,r,oC has permission to buil Classification- SSP` Dwelling_li ng Zo . ne Owned by Lot_ 16 Block 12 _S/D. SM#8 House No rE�st According to approved plans which are part of this permit P NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE IN- SPECTED BEFORE POURING. PERMIT VOID SIR MONTHS u AFTER DATE OF ISSUE 1141-1111. 0 Building material, rubbish and debris ifrom this work must not be placed in Public space, and must be cleared up and hauled away by either contractor or owner. Building Official. FOR OFFICE PERMIT USE ONLY NUMBER DATE CONTRACTOR PLUMBING n ELECTRICAL ,f - HEWER WATER a. �k g t DEPARTMENT OF BUILDING 3545 f CITY OF ATLANTIC BEACH, FLORIDA PERMIT NO. PERMIT TO BUILD THIS PERMIT MUST BE POSTED ON JOB Date 11/29 197 : � p Valuation$ Fee $ 1 t E This permit not valid until above fee has been paid to City Treasurer, and is ra-abject to revocation for violation of applicable provisions of law. This is to certify that Cardinal Plumbing Co. has permission to build tm install 1 sink, 2 lavator&es, 1 bath t 2 closets, 1 shower, 1 water heater, 1 dishwasher, 1 d 'n 1, and 1,�as iJnV machine. C as icatlon res i '.n 13 7nne t Owned by E. 3• Toney. Inc. Lot 16 Block 12 S/D SM#$ House No. 1707 Park Terrace West According to approved plans which are part of this permit NOTICE—ALL CONCRETE FORMS AND FOOTINGS MUST BE IN- SPECTED BEFORE POURING. PERMIT VOID SIR MONTHS AFTER DATE OF ISSUE ♦ � �– ► O Building material, rubbish and debris from this work must not be placed in public space, and must be cleared up and hauled away by either contractor or owner. R.C. Vogel Building official. FOR OFFICE PERMIT DATE CONTRACTOR USE ONLY NUMBER PLUMBING ELECTRICAL SEWER WATER E 0 7N 0 V2 91977 OF ATLANTM OUCH#, 0,01 5V,t F- an rsaa 'wr %7*-L4rf fit, cxr W, AM F I Xr�pr�5 ,Zy f4,,r.Ftm MST, S.7 "dow C17Y OF AnAMM BEACH WATER CONNEEM ON CHMME mmom IFI —E nksm TYPE tN: 1 GROUP CONS I STING OF _9"M STALL. DOMESTO C C2 UNIM VAM CLOW, LAVATORY A BATHM OR tMOMER STALL (6 UNITS) .,_.�� (GROW) PER HEA€ (3 U N01 OAS (WITH OR WI Tmff a91!{JR — OW-1 ShMK b 3 UNITS) *Jb SCAM) (2 LIM T") tN11'TS) FLUSHI Rl* SINC (B tail TS) �R Q3 SERYL SI Ni-TRAP STAND (3 UNITS —CMI*%TI ON 31N( & TRAY T5) SERV I CE S O NK-P 7W4P 0 UNITS) _.,,_ mw!*%TI GN SING a fluff 000* DISPOSAL. UNt9"' (4 UNITS) . * {4 !NITS) ..�...JMOAL MT OR CMI DOFt Cit' tM T) 1NR9 NAt., PEDESTAL, 5►1EPH0ht .tE7, OL.OMOUT (a tN1 TS) r:"AWCA. LAVATORY (1 !KNIT)-' _._.t,N1NAL., MALL. LIP {4 UNITS) I-09 (Z UNI15f _.._..JMNAL STALL, WASHOUT (4 UNITS) ._,...., NAI. TRAM {EACH 2-ff. SEcTI o MAINS (1 Ufjltj` (2 UNITS) Ii � SI NK {2 tilt TS)'- -L,,,,,"*N6 LI►0*ME 04S.) {3 tm Ts) .. 130 71 S I tK M/FOOD MASTF'ilwim .,GNASH SINK. EACH SET CF FMXX t5 �3 UNITS) (2 =75) .,...,.,,,,gJ VATr'Nk1t (I UNIT) _tM1'L"Nt CLOSET, TANK-OPE!#MD (4 ON TS) ,--LAVATORY.AVATORY. , BEAUiY Il an (9 !NITS) JAM CLOSET, VALVE-OPERAIM �.-LAVATORY, SAMMIS (s UN(T"SY to a"TS) LAMMY Tw 62 UM TS�; loz G" . U-J CITY OF ATLAWn C: SCACH .tCATI(m EOE ~1N APPLICATICH IS HEREBY WOE FOR 3/4,_T,alD NATER CLI{'-8 N AT 711E FOLLCKINR ADDRESS FAIR _ l UNIT(S). CW-SN Q#M OF _A5.09 + 2,,09 const. water PRIEff 90. 1707 Park Terrace West Ltd' 16..�� SLOCXC ..._.,12SCWBVtS1C" ACVAW No. MAS E. J. Toney, Inc. , 3202 Ocean D -lax ET 250 MAI LI ld A-DORM DATE om NO. DATE 0 NSTMUED ale s7 le CON KrIPA 'EC MACH Q � 1707 Park Terrace West q'OT 1Mcm Residential .s..•,�.a-�..�,a�..�w�... YS�i 4�l�Y'i"s3{YOgTQa■w�L"o+iNiY:a�.szaa�sapemw��+JRY/v / 4 -lYD WY'D 4vYlYYYt+iY�ifmY'+M�+WMwaweius+D:4 x 1l�ofYY �I'YY.�ca.WYtvai�a'atmalw' sici