Loading...
Permit Mech 1148 W Linkside Ct 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00000654 Date 5/25/12 Property Address . . . . . . 1148 W LINKSIDE CT Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SANTORA, J.BRAD HUXHAM HEATING & AIR 1148 LINKSIDE CT.W. 2101 FLORIDA BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 246-6721 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/21/12 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904)247-5845 11 PERmrr JOB ADDRFSS: PROJECTVALUE $ ZSOO� NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating_ Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# V91!V1-23y Air Conditioning: Unit Quantity Tons Per Unit REQUIW Heat: Unit Quantity L BTU's Per Unit 3& Seer Rating �oyo Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company 11AM W14:, 1 112- Office PhoneAO.6,2;1 Fax oqq(5-037 7 Co. Address: OL-1-01 /01Z�C)A I Allvd City ltQW4 6tilq State f7-.Zip,39-,'166 License Holder(Print): &N V\N�- ; State Certification/Registration# cocaos/5— Notarized Signature of License Ho S and subscribed befo e this ay o SHIRLEY L GRA MY COMMISSION#D e of Notary Publi EXPIRES:February 14,2014 3crtded Thru Notary Public Underwriters Job: 52312 roject Summary Date: May 23,2012 ndre House By: Erin Rodriguez Project Information For: Santora Residence 1148 Linkside Court W, Atlantic Beach, FL 32233 Notes: HUXHAM - a/c install Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 92 OF Inside db 68 OF Inside db 76 OF Design TD 29 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 56 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16604 Btuh Structure 18425 Btuh Ducts 5347 Btuh Ducts 7599 Btuh Central vent (57 cfm) 1803 Btuh Central vent (57 cfm) 994 Btuh Humidification 0 Btuh Blower 0 Btuh Plplqg 0 Btuh Equipment load 23753 Btuh Use manufacturer's data n Ratelswing multiplier 0.97 Infiltration Equipment sensible load 26207 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2213 Btuh Ducts 1915 Btuh Heating coolin Central vent (57 cfm) 2153 Btuh Area(ft 2 202B 2029 Equipment latent load 6281 Btuh Volume(ft3) 17854 17854 Air changes/hour 0.32 0.16 Equipment total load 32488 Btuh Equiv.AVF (cfm) 95 48 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make TRANE 13 SEER Make TRANE13SEER Trade Trade Model 4TWR3036 Cond 4TWR3036 ARI ref no. 4941234 Coil GAF2AO36 ARI ref no. 4941234 Efficiency 0 HSPF Efficiency 0 EER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47OF Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 1024 cfm Actual air flow 1024 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.81 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -rk vvrj0j_jt:MC3,ftr, Right-Suite4l)Universal 7.1.09 RSU01508 2012-May-23 10:43:07 ,C55k c:\users\erin\Documents\Wrightsoft HVAC\Template\Santora-Huxtiarn.rup Calc=M.18 Orientation Page I CERTIFIEDT. www.ahridirectory.org Certificate of Product-Rafings ._, AHRI Certified Reference Number: 4941234 Date: 5/25/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWR3036131 Indoor Unit Model Number: GAF2AOA36S31+TDR Manufacturer: TRANE Trade/Brand name: XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 34600 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 34800 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh)@ 17 F: 21400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accornpanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe products),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents ofthis Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on AFOU ON ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129824307237892374