Permit Mech 1148 W Linkside Ct 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00000654 Date 5/25/12
Property Address . . . . . . 1148 W LINKSIDE CT
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SANTORA, J.BRAD HUXHAM HEATING & AIR
1148 LINKSIDE CT.W. 2101 FLORIDA BLVD.
ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266
(904) 246-6721
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 11/21/12
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904)247-5845
11 PERmrr
JOB ADDRFSS:
PROJECTVALUE $ ZSOO�
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating_
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI# V91!V1-23y
Air Conditioning: Unit Quantity Tons Per Unit REQUIW
Heat: Unit Quantity L BTU's Per Unit 3& Seer Rating
�oyo
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Phone Number
Mechanical Company 11AM W14:, 1 112- Office PhoneAO.6,2;1 Fax oqq(5-037 7
Co. Address: OL-1-01 /01Z�C)A I Allvd City ltQW4 6tilq State f7-.Zip,39-,'166
License Holder(Print): &N V\N�- ; State Certification/Registration# cocaos/5—
Notarized Signature of License Ho S and subscribed befo e this ay o
SHIRLEY L GRA
MY COMMISSION#D e of Notary Publi
EXPIRES:February 14,2014
3crtded Thru Notary Public Underwriters
Job: 52312
roject Summary Date: May 23,2012
ndre House By: Erin Rodriguez
Project Information
For: Santora Residence
1148 Linkside Court W, Atlantic Beach, FL 32233
Notes: HUXHAM - a/c install
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 92 OF
Inside db 68 OF Inside db 76 OF
Design TD 29 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 56 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16604 Btuh Structure 18425 Btuh
Ducts 5347 Btuh Ducts 7599 Btuh
Central vent (57 cfm) 1803 Btuh Central vent (57 cfm) 994 Btuh
Humidification 0 Btuh Blower 0 Btuh
Plplqg 0 Btuh
Equipment load 23753 Btuh Use manufacturer's data n
Ratelswing multiplier 0.97
Infiltration Equipment sensible load 26207 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2213 Btuh
Ducts 1915 Btuh
Heating coolin Central vent (57 cfm) 2153 Btuh
Area(ft 2 202B 2029 Equipment latent load 6281 Btuh
Volume(ft3) 17854 17854
Air changes/hour 0.32 0.16 Equipment total load 32488 Btuh
Equiv.AVF (cfm) 95 48 Req. total capacity at 0.70 SHR 3.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make TRANE 13 SEER Make TRANE13SEER
Trade Trade
Model 4TWR3036 Cond 4TWR3036
ARI ref no. 4941234 Coil GAF2AO36
ARI ref no. 4941234
Efficiency 0 HSPF Efficiency 0 EER
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh @ 47OF Latent cooling 0 Btuh
Temperature rise 0 OF Total cooling 0 Btuh
Actual air flow 1024 cfm Actual air flow 1024 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0.039 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.81
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
-rk vvrj0j_jt:MC3,ftr, Right-Suite4l)Universal 7.1.09 RSU01508 2012-May-23 10:43:07
,C55k c:\users\erin\Documents\Wrightsoft HVAC\Template\Santora-Huxtiarn.rup Calc=M.18 Orientation Page I
CERTIFIEDT.
www.ahridirectory.org
Certificate of Product-Rafings ._,
AHRI Certified Reference Number: 4941234 Date: 5/25/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 4TWR3036131
Indoor Unit Model Number: GAF2AOA36S31+TDR
Manufacturer: TRANE
Trade/Brand name: XR13 WEATHERTRON
Manufacturer responsible for the rating of this system combination is TRANE
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 34600
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 34800
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh)@ 17 F: 21400
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accornpanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe products),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on AFOU ON ILI and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129824307237892374