Permit Mech 440 Garden Ln 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00000691 Date 6/04/12
Property Address . . . . . . 440 GARDEN LN
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
HASSI EDWARD D WATSON HEATING AND AIR
81-83 GRANT ST #7 4456 SUNBEAM RD
JERSEY CITY NJ 07302 JACKSONVILLE FL 32257
(904) 899-6830
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/01/12
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 9S . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, Fl, 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOBADDRESS: 4-40 GAO—OeJ 1-nOE PERMIT#
PROJECTVALUE $ ARI# 3-7 1 "7
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit -2-
Heat: Unit Quantity BTU's Per Unit Seer Rating 4
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name E 1� L-)A e-0 140 5 73 1 Phone Number
Mechanical Company OJ-0-175 cl-J 4 43 t C- Office Phone 8 2�?-683-o Fax
Co. Address: 14S(o �JJ GeD(Y\ P-o 37-E ?�DQ> city JAX State fc- Zip 3 Z- �7
License Holder (Print): P'no ( NA C—UGIU�-a State Certification/Registration C 18 f C- 8 �
Notarized Signature ofLicense Holder
S�IRLEY L GRNW 1 d subscribed me is .20
y
My COMMISSION.
of Notary Public
C ERTI A E D
ir6 I r y g
viww tifirid r ;1
Certificate of Proquict Rafilng; s
AHRI Certified Reference Number: 3717391 Date; 65/4/2012
Product: Split System: Heat Pump with Remote�utdoor Unit-Air-Source
Outdoor Unit Model Number: N4H324A(G)KE* I
Indoor Unit Model Number: FXM4X24**A*
Manufacturer: COMFORTMAKER
Trade/Brand name: 13 SEER N SERIES R410A HP
Manufacturer responsible for the rating of this ls�ystem combination is COMFORiMAKER
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air�Conditioning and Air-Source
Heat Pump Equipment and subject to veriflcatio� of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 23200
EER Rating (Cooling): 11.50
SEER Rating (Cooling): 14.00
Heating Capacity(Btuh)@ 47 F: 22600
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh) @ 17 F. 13500
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS which in icales an involuntary rerate
DISCLAIMER
AHRI does not endorse the produegis)listed on this Certificate and makes no r4presiantaWns,wa,T@nU4)s c�gu arantees asi to,and assumes no responsibility for,
the product(*)listed on this Certificate.AHRI expressly disclaims oil fisibll�y to-damages of any kind sr;sIn j ot,t of the uselor performance orf this productl[s),or the
M.ithor'—d afteration of darm listed on this Certificate.Certified irritings 4re vi lid only for models and cant gui allc ns Me in the directory at www.ahridirector*y.org.
TERMS AND CONDITIONS tell
This Cerfiftaile and Its contents are proprietary products ofAHRI.This Cortific ita shall only be us A foi inc ivid ual personliland co,iflosittiW reference purposes.
The contents of this Certificate may not,In whole or In part be repiodtic";cooled;disseminated;entered into a computsi�daUbase;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for Ove model cited on this certificate can be verified at v".ahridir4ectory.org, Ll I Air-Conditioning,Heating,
click on"Verify Certificate"Unk and enter thaAHRl Certified Roferarv-&N4mber and the date on and Refrigeration Institute
which the cerIftate was issued,which is Halted above,und the Certift^-vto Mo.,which is listed bolm
02012 Air-Conditioning,Heating,and Refrigeration institute CERTIFICATE NO.: 129832833188073900
Residential System Si:zing Calculation
Sumnary
Edward Hassi Project Title:
440 Garden I-Ane The Hassi Residence
Atlantic Beach, FL 32233-
6/2/2012
Location for weather data: Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M)
Humidity data: Interior RH (50%) Outdoor wet bulb (7 F) Humidity difference(53qr.)
Winter design temperature(MJ8 99%) 32 F Summer design temperature(MJ8 99%) 93 F
Winter setpoint 70 F Summer setpoint 75 F
Winter temperature difference 38 F Summer tE)mperature difference 18 F
Total heating I ad calculation 24494 Btuh Total coolina load calculation 25326 Btuh
Submitted heating capacity %of calc Btuh Submitted cooling capacity % of calc Btuh
Total (Electric Heat Pump) 111.9 27400 Sensible (SHR =0.75) 108.7 20550
Heat Pump +Auxiliary(O.OkW) 111.9 27400 Latent 106.6 6850
Total (Electric Heat Pump) 108.2 27400
WINTER CALCULPTIONS
Winter Heating Load(for 786 sqft) Verdilwion(9%) VIAnd—(6%)
Load component L oad C.fli"gs(6%)
Window total 89 sqft 1522 Btuh
Wall total 1023 sqft 2 978 Btuh VV'11'f1 2%)
Door total 40 sqft 69.9 Btuh
Ceiling total 786 sqft 1464 Btu�,i
Floor total 786 sqft 11483 Btu i
Doors�31X
Infiltration 52 cfm 2188 Btu,)
Duct loss 2065 Btuh
Subtotal 2240(3 Btuh
Ventilation 50 cfm 2083 Btu,i
TOTAL HEAT LOSS 24494 Btuh Flairs(47%)
SUMMER CALCULATIONS
Summer Cooling Load (for 786 sqft)
Load component Load
Window total 89 sqft 2044 Btuh
Wall total 1023 sqft 1599 Btuh
Door total 40 sqft 534 Btuh
Ceiling total 786 sqft 1657 Btuh
Floor total 3930 Btuh
Infiltration 42 cfm 829 Btuh
Internal gain 5190 Btuh
Duct gain 2128 Btuh
Sens. Ventilation 50 cfm 989 Btuh
Blower Load 1) Btuh Froo,�(16%)
Total sensible gain 16900 13tun A.G—,k201
Latent gain(ducts) 516 Btuh
Latent gain(infiltration) 1509 Btuh Doors(2%)
Latent gain(ventilation) 1800 Btun
Latent gain(internal/occupants/other) 2600 Btun
Total latent gain 6426 Btuh
I TOTAL HEAT GAIN 25326 Btuoj
EnergyGaug:)@ Systern Sizing
8th Edition PREPARED 13�:
DATE:
EnergyGauge@ USRFZB v2,8
System Sizing Calculations - Winter
Residential Load - Whole House Component Details
Edward Hassi Project Title:
440 Garden I-Ane The Hassi Residenca
Atlantic Beach, FL 32233- Buildirg Type: User
6/2/.'oi2
Reference City: Jacksonville, FL (Defaults) Winter Tempeirature Differonce: 38.0 F (MJ8 99%)
Comllonent Loads for Whole H'
ouse
Window Panes/Type Frame U Orientation Area(sq-�LX HTM= Load
1 2, NFRC 0.33 0 0.45 N 18.0 17.1 308 Btuh
2 2, NFRC 0.33 0 0.45 E 27.0 17.1 462 Btuh
3 2, NFRC 0.33 0 0.45 S 32.0 17.1 547 Btuh
4 2, NFRC 0.33 0 0.45 W 9.0 17.1 154 Btu h
5 2, NFRC 0.33 0 0.45 W 3.0 17.1 51 Btuh
Window Total 89.0(sqft) 1522 Btuh
Walls Type Ornt. Ueff. R-Value Area X IdTM= Load
(Cav/Sh)
1 Frame - Wood Ext (0.077) 13.0/4.1 262 2.91 763 Btuh
2 Frame - Wood Ext (0.077) 13.0/4.1 269 2.91 783 Btuh
3 Frame - Wood Ext (0.077) 13.0/4.1 208 2.91 606 Btuh
4 Frame - Wood Ex'; (0.077) 13.0/4-1 284 2.91 327 Btuh
Wall Total 023( qft) 2978 M0
Doors Type Storm Ueff. A,�ea X HTM= Load
1 Wood - Exterior, n (0.460) 20 17.5 350 Btuh
2 Wood - Exterior, n (0.460) 20 17.5 350 Btuh
Door Total 40(soft) 69913tuh
Ceilings Type/Color/Surface Ueff. R-ValLe Area X l-lTM= Load
1 Vented Attic/L/Shing (0.049) 19.0/00 786 1.9 1464 Btuh
Ceiling Total -'-786(sf1ft) 1464Btuh
Floors Type Ueff. R-Value S!ze X HTM= Load
1 Raised - Open (0.385) 0.0 786.0 sqft 14.6 11488 Btuh
Floor Total 786 sqft 11488 BtLh
Envelope Suhtotal: '18152 Btu.;1
Infiltration Type ACH Volume(cuft) Wall Ratio CFM=
Natural(Adjusted for ventilation) 0.50 6288 1.00 52.4 2188 Btuh
Duct load Average sealed, R6.0, Supply(Att), Return(Att) (D LM of 0.102) 2065 Btuh
All Zones Sensihie Subtotal All Zones 22406 Btuh
EnerqyGauge@/USRFZ3v2.8 Page I
Manual iminter Calculations
Residential Load - Component Details ((..,ontinued)
Edward Hassi Project Title:
440 Garden L-Ane The Hassi Residence
Atlantic Beach, FL 32233- Building Type: User
6/2/2012
777-
A'/'!��
HOLE HOUSE TOTALS
Subtota! Sensible Heat I.oss 22406 Btuh
Totals for Heating Ventilati,in SEnsible Heat Loss 2088 Btuh
To�al Heat Loss 24494 Btuh
EQUIPMENT
1. Electric Heat Pump 27400 Btuh
Key:Window types-NFRC (Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values)
or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults)
U-(Window U-Factor)
HTM-(ManuaIJ Heat Transfer Multiplier)
Version 8
EnergyGauge(D/USRFZB v2.8 Page 2
systern S"urnrne..
Residential Lc.,ad- "A�Iiole I)lis( Component Deta,'!c;
Edward Hassi Project Title:
440 Garden I-Ane The Hassi Resideiice
Atlantic Beach, FL 32233-
6/2/2012
Reference City: Jacksonville, FL Temperature Difference: 18.OF(MJ;3 99%) Humi&ydifference 53gr.
Component Loads for Whole House
HTIVI Load
Type* Overhang Window Area(sqft)
Window Panes SHGC U InSh IS OmLLen Gross Shaded Unshaded Shaded Unshaded
1 NFRC 0.33,0.45 No H N 1.5ft 'i.Oft 18.0 0.0 18.0 13 13 1143 Btuh
2 2 NFRC 0.33,0.45 No H E I.5ft 1 Oft 27.0 2.2 24.8 13
36 919 Btuh
3 2 NFRC 0.33,0.45 No H S 1.5ft ' Oft 32.0 32.0 0.6 13 16 432 Btuh
4 2 NFRC 0.33, 0.45 No H W 1.5ft i.Oft 90 0 7 83 1 13 36 306 13tuh
5 2 NFRC 0.33, 0.45 No H W 1.5tt i Oft 3.0 0.2 LE, 13 36 102 Btuh
Excursion 42 Btuh
Window Total 89 (sqft) 2044 Btuh
wails type----- -U-V-a--1u--e-- -R---V-a-Iu-e-----A:--ea-(sq,-f t-) --H-T--M- Load
��av/Sheath
1 Frame-Wood-Ext 0.)8 13.0/4.1 262.0 1.6 409 Btuh
2 Frame-Wood-Ext 0.08 13.0,,4.1 2)9.0 1,6 420 BtUh
3 Frame-Wood-Ext 0.)8 13.0/4.1 4208.0 1.6 325 Btuh
4 Frame-Wood-Ext 0.08 13.0/4.1 234.0 1.6 444 Btuh
Wall Total II(M (scft) i 1 599 8tuh
Mo-o-r-s Type Arep, (sqft) HTM Load
1 Wood-Exterior 20.0 13.3 :.'67 Btuh
2 Wood-Exterior 20.0 13.3 i '167 Btuh
I Door Total 40 (sqft) 4 Btuh
--CeiHn-gs '-Type-/,Colo-r-/S�ace- -U- --V-a-lj-e- I 1--V-al-ue---A---ea-(sqft) HTM Load
1 Vented Attic/Light/Shincile 0.049 1 M/0.0 7'36.0 2.11 1657 Btuh
Ceiling Total 786 (sqft) 1657 3tuh
loors Type R-Value Size HTM Load
1 Raised-Open 0.0 786(sqft) 5.0 3930 Btuh
Floor Total 786.0 (sqft) 3930 B
Envelope Subtotal: 9764 Btuh
[infiltration Type ACH Volume(cuft) Wa!l Ratio CFM= Load
SensibleNatural 1.40 6283 -1023 52.4 829 Btuh
In al B-tu-hOo-ccu-p-&-nt -A`pp-Iia-nce-[ Load
6in Occupants
i gain 3 X 230 + 450
0_ 5190 Btuh
Sensib e Envelope Load -1,13783 Btuh
Duct load Average sealed,Supply(M.O-Mjc), Return(R6.0-Attic) (OGM of 0.135) 2128 Btuh
Sensibl,.� Load All Zones 17911 Btuh
EnergyGauge@ USRFZ.B v2.8 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Edward Hassi Project Title: Climate:.:7L-,JACKSONVIL'LE_._INTL—AF3PT
440 Garden LAne The Hassi Residence
Atlantic Beach, FL 32233-
6/2/2012
-777- 7
"OL HOUSE TOTALS —
Sensible Enwope Load All Zones 15783 Stuh
Sensible Duct Load 2 1'2 8 Btu h
Total Sensible Zone Loads 179,11 Btuh
Sensiblc- ventilation 989 3tuh
Blower 0 Btuh
Whole House Total sensible gain 18900 Btuh
Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 1509 Btuh
Latent veritilatiun gain 1800 Btuh
Latent duct gain 516 -'3t(u h
Latent occupant gain (3 people Cp 200 Btuh per persorl) 600 Bt u h
Latent other gain 2000 Btuh
Latent total gain 6426 Btuh
'TOTAL G,',tlN 25326 Btuh
—7]
EQUIPMENT
3''
1. Central Unit # 21'-100 B'I�uh
Window types(Panes-Number and lype )f panes of glass)
(SHGC-Shading coeffirient of glass as SHGC r umerical value)
(U-Window U-Factor)
(InSh-Interior shading device:none(No), Blinds(B), Draperies(D)or Roller Shades(R))
For Blinds:Assume medium color, half closed
For Draperies:Assume medium weave, half closed
For Roller shades:Assume translucent, half closed
(IS-Insect screen:none(N), Full(F)or Half('/2))
(Ornt-compass orientation)
Version E
Enei,lyGauge@/ JSRFZB v2.8 Page 2
Trane Product Data
lCondenser I Ton. lindoor Unit --FME��SPF ITotal CapIS:ensible Cap��
2TWB3018Al 1.5 2TEC;3Fl8Al 13 7.7 1,3300 12100
2TWB3024Al 2 2TEC;3F24Al 13 7.7 22500 16900
2TWB303OAl 2.5 2TEC3F:�OA1 13 -.7 27400 20000
2TWB3036Al 3 2TEC3F":6AI 13 1.7 3-3400 � 24400
2TWB3042Al 1 3.5 12TEC3F42Al 1 7.7 3 3500 1 28800
2TWB3048Al 1 4 12TEC3F48A! 13 77-7 -4=00 - 328(00
2TWB306OAl 5 ;3F6OAl 3 7.7 55500 39500