Permit Mech 1717 Selva Marina Dr 2012 ck CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00000745 Date 6/13/12
Property Address . . . . . . 1717 SELVA MARINA DR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 4800
----------------------------------------------------------------------------
Application desc
Change out 3 . S ton system
----------------------------------------------------------------------------
Owner Contractor
------------------------
------------------------
EASTLACK, RICHARD JOHN HUXHAM HEATING & AIR
1717 SELVA MARINA DR 2101 FLORIDA BLVD.
ATLANTIC BEACH FL 322335617 NEPTUNE BEACH FL 32266
(904) 246-6721
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . . CHANGE OUT 3 . 5 TON SYSTEM
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/10/12
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 107 . 00 107 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax(904) 247-5845
JOB ADDRESS: n Sf-La ra Ae, PERMIT#
in
PROJECT VALUE $ '/,F&?O ARI# ej1,SG33A&
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit 3,-5
Heat: Unit Quantity I BTU's Per Unit MeVO Seer Ratin 13
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
9 Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name &6-UAC t& Phone Number
Mechanical Company —Office Phone9q4-0.11 Fax,9W
a& � A 4- -W 7,7
Co. Address: a)v i Rorbo9,h y%Ld city---EV6. - State 47f Zip._SaLA(.,0
License Holder(Print): A k State Certification/Registration#CjqC057,q
Notarized Signature of License Ho 42�� . --_L1
Swo and subscribed before e hi day of \20 4�_
D830RAH
AWNDA WHrM
h4y COWISSION#EE 057349 gnature of Notary Public
EXPIRES:May 21,2015
awdel Thni Notwy P-bffc U,&,,M,
Job: 612124
Project Summary Date: Jun 12,2012
Entire House By: Erin Rodriguez
Project Information
For Eastlack
1717 Selva Marina Drive,Atlantic Beach, FL 32233
Notes: HUXHAM -a/c change out
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 92 OF
Inside db 68 OF Inside db 76 OF
Design TD 29 OF Design TD 16 OF
Daily ranr L
Re ative umidity 50 %
Moisture difference 56 gr1lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 23926 Btuh Structure 22540 Btuh
Ducts 4678 Btuh Ducts 6548 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 28604 Btuh Use manufacturer's data n
Rate/swing multiplier 0.97
Infiltration Equipment sensible load 28215 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 1214 Btuh
Ducts 1657 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft') 1040 1040 Equipment latent load 2872 Btuh
Volume(ft') 8320 8320
Air changes/hour 0.59 0.23 Equipment total load 31087 Btuh
Equiv.AVF(cfm) 82 32 Req. total capacity at 0.70 SHR 3.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make TRANE Make TRANE
Trade Trade
Model 4TWR3042 Cond 4TWR3042
AHRI ref no4563326 Coil 4TEC3F42
AHRI ref no.4563326
Efficiency 0 HSPF Efficiency 0 SEER
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh @ 47'F Latent cooling 0 Btuh
Temperature rise 0 OF Total cooling 0 Btuh
Actual air flow 1179 cfm Actual air flow 1179 cfm
Air flow factor 0.041 cfm/Btuh Air flow factor 0.041 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.91
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2012-Jun-12 2312:08
wrightsoft, Pight-SudeO universal 2012 12.0.07 RSL)01508 Pagel
lc� C:Uwrs�erin\Docunients\WrightwftHVAC\Template\Easuackrup Ca1c=MJ8 FrontDoortaoes: N
CERTIFIEDTM
www.a h rid i rec to ry.Org J A I
Certificate of Product Ratings
AHRI Certified Reference Number: 4563326 Date: 6/13/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 4TWR3042B1
Indoor Unit Model Number: 4TEC3F42C1
Manufacturer: TRANE
Trade/Brand name: XR13 WEATHERTRON
Manufacturer responsible for the rating of this system combination is TRANE
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 40500
EER Rating (Cooling): 10.50
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 39500*
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh) @ 17 F: 26800
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accornpanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed an this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the Use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information forthe model cited on this certificate can be verified atwww.ahridirectory.org, Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on ANOW! 00 ILI and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129840814988590993