Loading...
1582 Ocean Blvd HVAC 2012 I A'j CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 tit Application Number . . . . . 12-00000758 Date 6/19/12 Property Address . . . . . . 1582 OCEAN BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BECK MARGERY R ET AL DONOVAN HEATING & AIR BECK DANIEL L & DEBORAH L R/S 315 SIXTH AVENUE SOUTH 1582 OCEAN BLVD JAX BEACH FL 32250 ATLANTIC BEACH FL 322335758 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . 6/18/12 Valuation . . . . 0 Expiration Date . . 12/15/12 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: PERMIT# PROJECTVALUE $ 11500 .1" NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI 4 %V-5 71/57 Air Conditioning: Unit Quantity Tons Per Unit 3 REQUIRED Heat: Unit Quantity BTU's Per Unit 36, 000 Seer Ratin 15- Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned Mor six months,I hereby certify that I h�averead this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name fflo-f- "R C Ck Phone Number J70 Mechanical Company "Daylovd-y-A 1-�a+ Office Phone 01-316 Fax-gYl- Z-7'IS Co. Address: -315 0 Ay-, city Z��X 9 C1111 State zip-32a�Eo_ License Holder (Print): zj/,� / State Certification/Registration CIY--o 9 76 Notarized Signature of License h(-ollder ANN M.WOOTEN Sworn and subscribed before me thisiLth day of )qorl 20a Notary Public,state of Florida Signature of Notary Public My Comm.exp.Jan.28,2013 Comm.No.DD 855678 Job: wrightsoft- Project Summary Date: June 15,2012 Enfire House By: Aaron Thacker Donovan Heat&Air 315 Oth Afe S,Jacksonville Beach,FL 32250 Phone:904-241-3785 Fax 904-241-3745 Emal:aaronQdonovanac.com Web:www.DonovanAC.com Project Information For: Margery Beck 1582 Ocean Blvd,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26705 Btuh Structure 20836 Btuh Ducts 4945 Btuh Ducts 4814 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh 131pigg 0 Btuh Equipment load 31649 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25651 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Aver Fireplaces 0 Structure 1154 Btuh Ducts 2066 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft') 1 W 1040 Equipment latent load 3220 Btuh Volume(ft ) 8320 8320 Air changes/hour 0.45 0.23 Equipment total load 28871 Btuh Equiv.AVF (cfm) 62 32 Req. total capacity at 0.75 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade BASE 15 PURON HIP Trade BASE 15 PURON HIP Model 25HBC536A**30 Cond 25HBC536A**30 AHRI ref no3645945 coil FX413N�B,F)037 AHRI ref no364594 Efficiency 8.7 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 26100 Btuh Heating output 35400 Btuh @ 47OF Latent cooling 8700 Btuh Temperature rise 28 OF Total coolin 34800 Btuh .g Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.037 cfnVBtuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J ft Ed. 20U-Jun-18 08:17:19 wrightSOft' Right-Suite40 universai 8.0.24 RSU05995 Page 1 ,4M C:lUsers�Owner\Documents\Wrightsoft HVAC\Bogus 3 ton.rup Calc-MJ8 Front Door faces: E This combination qualifies for a Federal Energy CERTIFIEDTly Efficiency Tax Credit when placed in service L www.ahridirectory.org between Feb 17, 2009 and Dec 31,2011. Certificate of Product Ratin � q s AHRI Certified Reference Number: 3645945 Date: 6/19/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC536A**30 Indoor Unit Model Number: FX4DN(B,F)037 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: BASE 15 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 34800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 35400 Region IV HSPF Rating (Heating): 8.70 Heating Capacity(Btuh)@ 17 F: 21400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out ofthe use or performance of the product(s),or the unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents ofthis Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "lop, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on 0%2 which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 00 ILI and Refrigeration Institute @2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129845928032401381