Loading...
5311 Fleet Landing HVAC 2012 CIT ( OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00000777 Date 6/22/12 Property Address . . . . . . 1 FL ET LANDING BLVD MAIN Tenant nbr, name . . . . . . UNIT S311 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC FLEET LANDING 6491 POWERS AVENUE 1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 32233 (904) 724-7211 ---------------------------------------- ------------------------------------ Permit . . . . . . MECHANICAL HVTIC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/19/12 ---------------------------------------- ------------------------------------ Other Fees . . . . . . . . . STA-E MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------- ------------------------------------ Fee summary Charged laid Credited Due ----------------- ---------- ---- ------ ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 I PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTI c BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (9(4) 247-5845 1 JOBADDRESS: -:L o04�okr) L-PERMIT# 3 -,�2,'3 1 DROJECT VALUE Oc NEW AIR CONDITIONING & HEATING SYSTEN I INSTALLATION Air Conditioning: Unit Quantity Tons Per Unii Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATI G SYSTEM INSTALLATION ARI# Air Conditioning: Unit Quantity Tons Per Unil REQUIR L Heat: Unit Quantity --I- BTU's Per Uj iit 0 0 C11 Seer Rating Duct Systems: Total CFM REQUIRELOFA FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity - (Requires 3 sets of plans) Underground Fire Main Value - (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) NA Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boiler i BTU's Elevat Drs/Escalators ALL OTHER GAS PIPING Heat 1xchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: M Permit becomes void if work does not commence within a six month period or work is s ispended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and on linances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or ocal law regulation construction or the performance of construction. Property Owners Name Ree 4 in) 1' V\ja Phone Number 2q6 -7yod Mechanical Company Nkj,t,) cry_G�_ qea� 11� Office Phone 7214—:1:21/-Fax Co. Address: 6�q 1 (2o uj e --, A�e Ywe/ - -- City T(, k S c nv, I(,- State_PC Zip 5 2-24 License Holder(Print): (��Ere4 Tock-eir A. State Cert,1ficalion/Registration# C_ C 5-11 Notarized Signature of License Holder Sworn and subscribed before n this "ay of U yj e 20 It 51" ur, Wow& of Notary Public, SHIRLEY L.GRAHAM My COMMISSION!,DD 957760 5VEXPiRSS:February 14 2014 Bonded Thru Notary Public UWdervAiters Right JO Mobile Report Job: wrightsoft Date: 6/22/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jarksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email.,rzabinsl@davidgrayonline.com Web:www.davidgrayonline.com Licens Project Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5311,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax:904-246-9455 Design Conditions Location: Ind or: Heating Cooling Jacksonville/Craig, FL, US In oor temperature (OF) 70 75 Elevation: 43 ft D sign TD (OF) 35 16 Latitude: 30 ON R lative humidity(%) 30 50 Outdoor: Heating Cooling isture difference(gr/lb) 8.4 52.8 Dry bulb(OF) 35 91 Infil ration: Dailyrange(OF) - 17 ( M IV athod Simplified Mt bulb(OF) - 77 C)nstruction quality Average Wind speed (mph) 15.0 7.5 F replaces 0 Heating Component Btu h/ft2 Btuh %of load Walls 8.3 12205 39.2 111Mcn Glazing 19.8 4262 13.7 Doors 13.5 433 1.4 Ceilings 1.7 2438 7.8 VW1 Floors 6.2 8963 28.8 Rocrs Infiltration 2.1 2869 9.2 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation !Gawrg 0 0 ahe(P�Iirgs Adjustments 0 1 Total 1 311701 100.01 Cooling Component Btu Me Btuh %of load Walls 4.0 5915 25.9 IrtelT-d Girs Glazing 48.7 10487 45.9 IrtiltrEfion Doors 11.4 367 1.6 V\blls Ceilings 2.6 3720 16.3 Gailirigs Floors 0 0 0 Infiltration 0.5 691 3.0 Ducts 0 0 ahT Ventilation 0 0 Internal gains 1660 7.3 Blower 0 0 Adjustments 0 Total 22840, 100.01 Gadrig Latent Cooling Load 1784 Btuh Overall U-wlue=0.152 Btuh/ft2-*F Data entries checked. wrightsoft 2012-Jun-22 06:42:05 Right-Suite(&Universal 2012 12.0.08 Right J0 Mobile Page 1 C:\VvINDOWS\TEMP\wstmpXO025dbf4-636a-4838-8e37-069befd5W6.rup Calc=MJ8 Fron Door faces:SE Job: wrightsoft- Project Summary Date: 6/22/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinO @davidgrayonline.com Web:www.da�Adgrayonline.com Licens Project Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5"M 1,Atlantic Beach, FL 32233 Phone:904-246-9900 Fax:904-246-9455 Notes: Design Information Weather: Jacksonville/Craiij, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 OF Outside db 91 OF Inside db 70 OF Insi(e db 75 OF Design TD 35 OF Des gn TD 16 OF Dail f range M Rek tive humidity 50 % Moii 1ure difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 31170 Btuh StrL ,tu re 22840 Btuh Ducts 0 Btuh Duc s 0 Btu h Central vent(0 cfm) 0 Btuh Cer sal vent(0 cfm) 0 Btuh Humidification 0 Btuh Bloi rer 0 Btuh Piping 0 Btuh Equipment load 31170 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22840 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 StrL cture 1784 Btu h Duc ts 0 Btuh Heating Cooling Cer tral vent(0 cfm) 0 Btuh Area(ft� 1438 1438 EqL ipment latent load 1784 Btuh Volume 10066 10066 Air changes/hour 0.45 0.23 EqL ipment total load 24624 Btuh Equiv.AVF(cfm) 75 39 Re(.total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Tra Je Model ARUF Cot id GSZ AHRI ref Coi AHRI ref Efficiency 0 AFUE Eftiency 13 SEER Heating input 0 Btuh Set sible cooling 0 Btuh Heating output 0 Btuh Lat,mt cooling 0 Btu h Temperature rise 0 OF Tot)l cooling 0 Btu h Actual air flow 1040 cfm Act jal air flow 1040 cfm Air flow factor 0.033 cfm/Btuh Air low factor 0.046 cfm/Btuh Static pressure 0 in H20 Sta:ic pressure 0 in H20 Space thermostat Lo,d sensible heat ratio 0.93 Calculations approved by ACCA to meet all 'equirements of Manual J 8th Ed. 2012-Jun-22 06:42:05 wirlightSOft Right-Suitee Universal 2012 12.0.08 Right J9 Mobile Page 1 C:\VANDOWSkTEMP\wstmp\0025dbf4-636a-4838-8e37-069befd56456.rup Calc=MJ8 F:)nt Door faces:SE .J. Job: Ir wrightsofto Right-M Worksheet Date: 6/2212012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jackso nville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsk V@davidgrayonline.com Web:www.daAdgrayonline.com Licens I Room name Ei fire House First Floor 2 Exposed wall 190.8 ft 190.8 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 1438.0 fit 5 Room area 1438.0 ft2 1438.0 ft2 I I I I Ty I Construction U-val Or (B HTM Area (ft2) (f) Load Area (ft') Load) t2_ meter (Btuh) or perimeter (Btuh number (Bt uh/fue-F) t uh/f 1:2) or part Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V" 15A-2s3oc-2 0'269 n 8A2 4 20 612 97 5029 2505 612 597 5029 2505 I D�c2ow 0.570 n 19.72 20.91 is 0 296 314 15 0 296 314 V�= 15A-2s3oc-2 0.269 a 8.13 3.78 234 71 1390 647 234 171 1390 647 10B-w 0.600 e 20.76 33.03 1B 0 374 595 18 0 374 595 1 D-c2ow 0.570 a 19.72 63.01 45 0 887 2835 45 0 887 2835 1 5A-2s3or-2 0269 se 7.37 25 11 83 25 11 83 31 t-1. -ID-c2ow 0*570 se 19.72 49.18 14 0 279 697 14 0 279 607 5A-2s3oc-2 0.269 a 8.32 4.05 594 17 4300 2092 594 517 4300 2092 I D-c2ow 0.570 s 19.72 25.16 45 0 887 1132 45 0 887 1132 11DO 0.390 s 13.49 11.43 32 32 433 367 32 32 433 367 15A-2s3or,-2 0*269 w 8ke 3168 252 74 1402 641 252 1174 1402 641 1 D-c2ow, 0.570 w 19.72 6101 30 0 502 1890 30 0 592 1890 1D-e2owd 0.570 w 19.72 63.01 48 0 947 3024 48 0 947 3D24 168-19ad 0.049 1,70 2.59 1438 1 Q8 2438 3720 1 438 1438 2438 3720 C 1 0 F 22A-cph 1.358 46.99 0.00 1438 191 8963 0 438 191 8963 1 6j c)AED excursion 0 0 Envelope loss/gain 283011 20489� 1 28301 204891 12 a) Infiltration 2869 691 28691 691 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 1200 1200 Subtotal(lines 6 to 13) 31170 22840 311701 9284n Less external load 0 0 0 Less transfer 0 0 0 Redistribution 0 0 0 14 Subtotal 31170 31170 22840 15 Duct loads 0% 0% 0 0% 0 0 Total room load 1 311701 228401 1 1 311701 228401 Air required(cfm) 1 040 1040 1 040 1040 Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. 2012-Jun-22 06:42:05 wrightsoft, Right-SuiteO Universal 2012 12.0.08 Right JO Mobile Page 1 .,Oft C:\\MNDOWS\TEMP\wstmp\0025dbf4-636a-4838-8e37-069befd56456.rup Calc=MJ8 Font Door faces:SE I Component Constructions Job: wirightsoft Date: 6/22/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FIL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsk(Mdavidgrayonline.com Web:www.davidgrayonline.com Licens Project Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5311,Atlantic Beach, FL 32233 Phone:904-246-9900 Fax: 904-246-9455 Design Conditi�ons Location: Indc or: Heating Cooling Jacksonville/Craig, FL, US In J oor temperature(OF) 70 75 Elevation: 43 ft D.-sign TD (OF) 35 16 Latitude: MON R alative humidity 30 50 Outdoor: Heating Cooling Disture difference(gr/lb) 8.4 52.8 Dry bulb(OF) 35 91 Infil,ration: Dailyrange(OF) - 17 M IV ethod Simplified Wet bu lb(OF) - 77 C)nstruction quality Average Wind speed(mph) 15.0 7.5 F replaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain ft2 Btuh/ft2-*F ft2-*F/Btuh Btuh/ft2 l3tuh 13tutiff Btuh Walls 15A-2s3oc-2:Bg wall,heavy dry or light damp soil,empty core, n 597 0.157 2.0 8.42 5029 4.20 2505 concrete block wall,r-2 ins,10"thk e 171 0.167 2.0 8.13 1390 3.78 647 se 11 1 0.157 2.0 7.37 83 2.71 31 S 517 0.157 2.0 8.32 4300 4.05 2092 w 174 1 0.157 2.0 8.06 1402 3.68 641 all 1470 0.157 2.0 8.30 12205 4.02 5915 Partitions (none) Windows 1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,cir innr,1/4"gap, n 15 0.570 0 19.7 296 20.9 314 1/8"thk e 18 0.600 0 20.8 374 33.0 595 e 45 0.570 0 19.7 887 63.0 2835 se 14 0.570 0 19.7 279 49.2 697 s 45 0.570 0 19.7 887 25.2 1132 w 30 0.570 0 19.7 592 63.0 1890 w 48 0.570 0 19.7 947 63.0 3024 all 215 0.570 0 19.8 4262 48.7 10487 Doors 11 DO:Door,wd sc type s 32 0.390 0 13.5 433 11.4 367 Ceilings 1613-1 gad:Attic ceiling,asphalt shingles roof mat,r-1 9 ceil ins,1/2" 1438 0.049 19.0 1.70 2438 2.59 3720 gypsum board int frish Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 191 1.358 0 47.0 8963 0 0 2012-Jun-22 06:42:06 +wrightSOft Right-Suitee Universal 2012 12.0.08 Right J(8)Mobile Page I C:NVIANDOWS\TEMPkwstmp\0025dbf4-636a-4838-8e37-069befd56456.rup Calc=MJ8 Fron Door faces:SE wrightsoft. AED Assessment Job: Date: 6122/2012 Entire House By: David Gray Heating and Air, INC. � 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinskt@davidgrayonline.com Web:www.davidgrayonline.mm Licens l Project Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5311,Atlantic Beach, FL 32233 Phone:904-246-9900 Fax: 904-246-9455 Design Conditions Location: Ind or: Heating Cooling Jacksonville/Craig, FL, US In oor temperature(*F) 70 75 Elevation: 43 ft JDsign TD (T) 35 16 Latitude: 30*N R lative humidity 30 50 Outdoor: Heating Cooling isture difference(gr/lb) 8.4 52.8 Dry bulb(T) 35 91 Infill ration: Daily range(T) - 17 ( M Wet bulb(*F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 14,00 12100c- 10,00 8100C 6,00G 4,,00G 2,00G 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day FbAy / Aerage AEDliMt Maximum hourly glazing load exceeds average by 25 2%. House has adequate exposure diversity (AED), basec on AED limit of 30%. AED excursion: 0 13tuh 2012-Jun-22 06:42:06 WrIghtACIlft Right-Suites Universal 2012 12.0.08 Right JS Mobile Page 1 C:\VANDOWS\TEMP\wstmp\0025dbf4-636a-4838-8e37-069befd5W6.rup Cak;=MJ8 Froni Door faces:SE