Loading...
Mech Fire Sprinkler for Dumpster canopy 2012 CIT OF ATLANTIC BEACH �.� 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 App " n Number . . . . . 12- 0000794 Date 6/27/12 RE number 170229-0000- - NCR OLD ACCOUNT NUMBERS . . . AB2 005 Application type description MECHANICAL FIRE PERMIT Subdivision Name . . . . . . AT TIC BEACH Property Use . . . . . . . . COMMERCIAL GENERAL Property Zoning . . . . . . . COM GENERAL DISTRICT Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ ASHFORD ATLANTIC BEACH LLP WAYNE AUTOMATIC FIRE SPRINKLER C/O EASLEY MCCALEB & ASSOC HAZARD FIRE PROTECTION ENG 431 E HORATIO AVE SUITE 120 222 CAPITOL COURT MAITLAND FL 32751 OCOEE FL 34761 (904) 268-3030 --------------------------------------- ------------------------------------ Permit . . . . . . MECHANICAL FIRE SPRINKLER Additional desc . . Permit Fee . . . . . 00 Plan Check Fee . 00 Issue Date . . . . 6/27/12 Valuation . . . . 0 Expiration Date . . 6/27/12 --------------------------------------- ------------------------------------ Special Notes and Comments this is a no chg all fees paid on permit # 12 122 --------- -------- -------- ------ ------- ------- ------- --- -------- --- Fee summary Charged aid Credited Due--------- ----------------- ---------- --- ------ ---------- ---------- Permit Fee Total . 00 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total . 00 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. s d MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic B ach, FL 32233 Ph (904) 247-5826 Fax (9 4) 247-5845 JosAvnuEss: ! c� T 1,4T I C'�� c L. 32-2--33 PE ROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTE INSTALLATION Air Conditioning: Unit Quantity Tons Per Uni Heat: Unit Quantity BTU's Per Ui Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unil ARI #REQUIRED Heat: Unit Quantity BTU's Per Ui tit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity 5_ (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quanfity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boiler BTU's Elevat)rs/Escalators ALL OTHER GAS PIPING Heat I xchanger Quantity of Outlets Pum #Vented Wall Furnaces Refrigerator rator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: ?ermit becomes void if work does not commence within a six month period or work is s spended or abandoned for six months.I hereby certify that I have read :his application and know the same to be true and correct. All provisions of laws and or nances governing this work will be complied with whether specified )r not. The permit does not give authority to violate the provisions of any other state or cal I&Deregulation struction or the performance of construction. Property Owners Name 54 FL> S4??i t i e L C p C oCcAtP onNumber 01 o IME I-T[,m TIS �� � Mechanical Company �1ZE SPR tti Office Phone 2f,?,--S-­3oFax 2&0-OI Z4. Co.Address: It 3Z I City_TP c 1cSzrd V t�c State FL. Zip 34z5(=1 License Holder(Print): S 4AA l ` t A AM Z State Certification/Registration# _6140`7 t00o►ZaD Votarized Signature of License Ho STEPHANIE PARROTT sworn anct subscribed before e this day o l,C f 201-1-- NOTARY PUBLIC STATE OF FLORIDA Signature of Notary Public bjh, aj-)L,1_ fAl'" CAz Comm#EE014521 . m 1s Expires 10/25/2014 Qs Q City of Atlantic Beach (V /V APPLICATION NUMBER Building Department ,w (1'o be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904)247-5845 „r F3 E-mail: building-dept@coab.us Date routed: City web-site- http://w AAi.coab.us APPLICATION REVIEW AN TRACKING FORM Property Address: / e eM7-) A61v0' De a ent review required Yeo No wilding Applicant: 1%�Vnk Az2 /,e� Zoning l Tree Administrator Project: Public Works Public Utilities V44 k r afety Fire Services ✓ Other Agency Review or Permit Required Review or Receipt Date of P parmit Verified B Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: (Approved. ❑Denied. (Circle one.) Comments: 6UILDIN PLANNING&ZONING Reviewed by: � Date.. TREE ADMIN. Second Review• A roved as revis ❑ pp ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed b : Date: FIRE SERVICES Third Review: ❑Approved as revise 1. [—]Denied. Comments: Reviewed b Date: Revised 07/27/10 YNIE Automatic Fire rig , I Hydraulic Calculations Wayne Automatic Fire Sprinklers, Inc. 11326 Distribution Aver ue West Jacksonville, FI. 32256-?745 904-268-3030 Job Name One Ocean 21x21 Canopy Sheet Number FP1 Location 1 Ocean Blvd., Atlantic Beach Florida 32233 Design Area 2 Contract 3251 Data File One Ocean Canopy.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 v I Wayne Automatic Page 1 One Ocean 21x21 Canopy Date 3/8/12 HYDRAULIC CALCUL TIONS for Projectname: One Ocean Canopy (21x21) Location: 1 Ocean Blvd., Atlantic Beach, Florida 32233 Drawing no: FP1 Date: 6/25/12 Design Remote area number: 2 Remote area location: Outside 21'x21' Canopy Occupancy classification: Light Hazard Density: .1 -Gpm/SgFt Area of application: Entire -SgFt Coverage per sprinkler. 102 -SgFt Type of sprinklers calculated: Tyco TY-B 5.6K 1/2" NPT Brass SSP No. of sprinklers calculated: 5 In-rack demand: -GPM Hose streams: 100 -GPM Total water required(including hose streams): 247.409-GPM @ 52.0217 - Psi Type of system: Anti-Freeze Volume of dry or preaction system: -Gal Water supply information Date: 12-13-2011 Location: Annual Fire Pump Test Source: Wayne Automatic Fire Sprinklers Name of contractor. WAYNE AUTOMATIC FIRE SPRINKLERS, INC Address: 11326 Distribution Ave W/Jacksonville, FL 32256 Phone number: 904-268-3030 Name of designer. David L. Blake, CET Authority having jurisdiction: City of Atlantic Beach Notes: (Include peaking information for gridded systems her.-.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1 Flow Diagram Wayne Automatic Page 2 One Ocean 21x21 Canopy Date 3/8/12 14.9 11 F- 12 <- 14 T 30.It 1 30.f 46.2 15.¢ 1 13 t- 14 E- 17 46.2 16.1 79.3 79.3 79.3 79.3 15 E- 16 E- 17 +-. 18 E- 5 <- 6 <-- 7 F- 8 9 e- 10 F EPD 33 79.3 79.3 79.3 179.3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1 l _ 0i MMN N O (D �� � N o O o 0 N O LO � . 00 M M 0 to co am ca' O 00 o v CC)00 oCl) ��� N NN CO CC (O OO O 0) N LO O N Ln LO LO co M 00 O M O Q CO 0 'IT MMM N I- LO Z Ln NN m L O NNNN O •Q� O C r M O 00 — — ` N OCO L9 LL d) 0 O M r t` r ` Q ED r Ul C N r- CD _O m C N p ` _p_ m U Q fa N LL. O > C]. N r LLL 'O N O C NCie- y" p +••' Z > O O U C'a cn ` « Lq U) OC LLC a N �'m O0)00 ^U V r -0 _ I U) L LT� C 'C 'O O 0 0 U C O m m L c N M'a On0 � C Cn N O U d �f C N w ` U L x ` ` N w w- E C N N En Oto Ln d U) t m '"m—O fC '+•+C E a O CD N t U Co Nm a.3 � n ON 0)OLO � O N 0 iT Cn m -0 N U ` _� t � () j 0 ,a I` jY w V D U) O �O N (p CO 0NLL ODM � �C LL C "0 d N - U) E m c o a � 0 C N N N 0) m N Y m N � o > 3> > � 03 • tom C c m _ m >.._ �mU N 0- 0 to 7 U �wa> rn~ v � d c N t t rn _ t > 3 V N m m w U' CO f' tm C O y m � u ��n r- o Z` ��' -j a � Q o EN m � rn `DdLL m o E ` O c r- m (D 0 0 G) o E 0 ccs.- c o n Q rnz (7rnli�C7rn 3 O ' o rn a>i Ern 3 ai >_ CL m e c � O 'c _!R o 0 0 ', � L � O iiQ m WLL U)F- 0 OJlid Z W ai m o t Pressure / Flow Summary - STANDARD i Wayne Automatic Page 4 One Ocean 21x21 Canopy Date 3/8/12 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. 11 17.0 5.6 7.0 na 14.82 0.1 102 7.0 12 17.0 5.6 7.75 na 15.59 0.1 102 7.0 13 19.0 5.6 7.99 na 15.83 0.1 102 7.0 14 17.0 10.01 na 15 17.0 5.6 8.26 na 16.1 0.1 102 7.0 16 17.0 5.6 9.13 na 16.92 0.1 102 7.0 17 17.0 11.89 na 18 20.0 22.83 na 5 20.0 23.32 na 6 20.0 24.05 na 7 20.0 24.79 na 8 20.0 25.52 na 9 20.0 26.25 na 10 7.0 43.93 na 100.0 EPD 2.0 46.18 na The maximum velocity is 17 and it occurs in the pipe between nodes 7 and 18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 i Final Calculations - Hazen-Williams Wayne Automatic Page 5 One Ocean 21x21 Canopy Date 3/8/12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv '** "*' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 11 14.82 1.049 0.0 10.000 7.000 K Factor= 5.60 to 120.0 0.0 0.0 0.0 12 14.82 0.0747 0.0 10.000 0.747 Vel = 5.50 12 15.58 1.049 1 E 2.0 6.000 7.747 K Factor= 5.60 to 120.0 0.0 2.000 0.0 14 30.4 0.2824 0.0 8.000 2.259 Vel = 11.29 0.0 30.40 10.006 K Factor= 9.61 13 15.83 1.049 1E 2.0 6.580 7.993 K Factor= 5.60 to 120.0 1 T 5.0 7.000 0.866 14 15.83 0.0845 0.0 13.580 1.147 Vel = 5.88 14 30.41 1.38 IT 6.0 5.670 10.006 to 120.0 0.0 6.000 0.0 17 4_6.24 0.1614 0.0 11.670 1.883 Vel = 9.92 0.0 46.24 11.889 K Factor= 13.41 15 16.10 1.049 0.0 10.000 8.262 K Factor= 5.60 to 120.0 0.0 0.0 0.0 16 16.1 0.0871 0.0 10.000 0.871 Vel = 5.98 16 16.92 1.049 1 E 2.0 1.375 9.133 K Factor= 5.60 to 120.0 IT 5.0 7.000 0.0 17 33.02 0.3291 0.0 8.375 2.756 Vel = 12.26 17 46.24 1.38 3E 9.0 13.000 11.889 to 120.0 IT 6.0 15.000 -1.299 18 79.26 0.4371 0.0 28.000 - 12.240 Vel = 17.00 18 0.0 2.067 0.0 8.000 22.830 to 120.0 0.0 0.0 0.0 5 79.26 0.0611 0.0 8.000 0.489 Vel = 7.58 5 0.0 2.067 0.0 12.000 23.319 to 120.0 0.0 0.0 0.0 6 79.26 0.0611 0.0 12.000 0.733 Vel,,= 7.58 6 0.0 2.067 0.0 12.000 24.052 to 120.0 0.0 0.0 0.0 7 79.26 0.0612 0.0 12.000 0.734 Vel = 7.58 7 0.0 2.067 0.0 12.000 24.786 to 120.0 0.0 0.0 0.0 8 79.26 0.0611 0.0 12.000 0.733 Vel = 7.58 8 0.0 2.067 0.0 12.000 25.519 to 120.0 0.0 0.0 0.0 9 79.26 0.0612 0.0 12..000 - 0.734 Vel = 7.58 9 0.0 2.067 8E 40.0 64.710 26.253 to 120.0 3T 30.0 83.250 8.630 Fixed loss= 3 10 79.26 0.0611 is 11.0 147.960 9.043 Vel= 7.58 1 B 2.25 1 Fsp 0,0-_ 10 100.00 6.357 1 E 17.603 10.500 43.926 Qa = 100 to 120.0 1G 3.772 61.610 2.166 EPD 179.26 0.0012 IS 40.235 72.110 0.083 Vel = 1.81 Computer Programs by Hydratec Inc. Rout 111 Windham N.H. USA 03087 Finat Calculations - Hazen-Williams Wayne Automatic Page 6 One Ocean 21 x21 Canopy Date 3/8/12 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C° or Ftng's Pe Pv """**** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 179.26 46.175 -KFactor= 26.38 Computer Programs by Hydratec Inc. Rout 111 Windham N.H. USA 03087 1 N co (D( Ln � DN 1- M D)Ln N OCl) � O N N a y (d 3 E o �a (D clia. cc c o maEiaEiEaEi °T° ov, v,prng w cn co (D N CTNN OM%(-U MCCOMCCO E N D c 0 M O O Q O (n (D T i z E (D rn ca LnOO�N C CO Ln r- S .. .. .. .. .. .- 3 O T o LL T m m m �° :3 : cn CO `n w uU a) �24) a.a.LL o N caa (nm � w y XC s (0 (UNC CD > U�wa. N Z CL CL CL CL CL E E E E E T � :3 :3 = � = �a.0.a.aa 0 m �TNNMM LJL d a.a.a.a.a. a` E a o a o E T Q U N O CL O 0 j o O y o cD > c U o T O 01d Z E N rl O O j CUN a U O O O O O O y c 0 LO M N T O O O O O O O O O O TT T T T T T 0) 00 ti (D Ln CP M N T > M � a. � w cn w 4 E s Wayne Automatic Page 1 One Ocean 21x21 Canopy Date 3/8/12 HYDRAULIC CALCUL ATIONS for Projectname: One Ocean Canopy (21x21) Location: 1 Ocean Blvd., Atlantic Beach, Florida 32233 Drawing no: FP1 Date: 6/25/12 Design Remote area number: 2 Remote area location: Outside 21'x21' Canopy Occupancy classification: Light Hazard Density. .1 -Gpm/SgFt Area of application: Entire -SgFt Coverage per sprinkler. 102 -SgFt Type of sprinklers calculated: Tyco TY-B 5.6K 1/2" NP Brass SSP No. of sprinklers calculated: 5 In-rack demand: -GPM Hose streams: 100 -GPM Total water required(including hose streams): 247. 09 - GPM @ 52.0217 - Psi Type of system: Anti-Freeze Volume of dry or preaction system: -Gal Water supply information Date: 12-13-2011 Location: Annual Fire Pump Test Source: Wayne Automatic Fire Sprinklers Name of contractor. WAYNE AUTOMATIC FIRE SPRINKLEF S, INC Address: 11326 Distribution Ave W/Jacksonville, FL 32256 Phone number. 904-268-3030 Name of designer. David L. Blake, CET CITY OF ATLANTIC BEACH Authority having jurisdiction: City of Atlantic Beach BUILDING OFFICE Notes:(Include peaking information for gridded systems he .) JiJN 27 2012 By: JUN } 2012 Computer Programs by Hydratec Inc. Routl 111 Windham N.H. USA 03087 Prescure / Flow Summary - STANDARD Wayne Automatic Page 4 One Ocean 21x21 Canopy Date 3/8/12 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 11 17.0 5.6 7.0 na 14.82 0.1 102 7.0 12 17.0 5.6 7.75 na 15.59 0.1 102 7.0 13 19.0 5.6 7.99 na 15.83 0.1 102 7.0 14 17.0 10.01 na 15 17.0 5.6 8.26 na 16.1 0.1 102 7.0 16 17.0 5.6 9.13 na 16.92 0.1 102 7.0 17 17.0 11.89 na 18 20.0 22.83 na 5 20.0 23.32 na 6 20.0 24.05 na 7 20.0 24.79 na 8 20.0 25.52 na 9 20.0 26.25 na 10 7.0 43.93 na 100.0 EPD 2.0 46.18 na The maximum velocity is 17 and it occurs in the pipe between nodes 17 and 18 Computer Programs by Hydratec Inc. Route I111 Windham N.H. USA 03087 h N r 00 (0(OLO lON M 0)UN� ) CD��O�0 a. N -p � (0 3 U) E o 2 CD cLia. CO c o °- EEEErn C 00 >° �°� °�°� c° r W ca cn"cn� U) �rNN OM (� mccomofn E N w O M O O Q O cn O � r Z E O O� t Ln00`ctN "C 'a'Cl)Lnrr C rrf`rr r 3 O O o 14. LL r x a � = U) - 3@ c c mmom3 13-LL - O ani LO C p p cn ` N x O N r Um�a� -C C:) _ aa.aaa CjZ E E E E E a.aa_aa. p E co J �1NNMM I L LL p as a_a_a_o_ E C) `m a O o Er 0 U IL o 0 0 1 O CL T O v O CO > C CU O U N r O D Q N U O O O O O O v ' o Ln -TM N r O C) 00 O CD C) O O O O A r r r r r r It M N r Co Oc a_ W 0 In n w W