Permit Mech 831 Bonita Rd 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00000875 Date 7/11/12 Property Address . . . . . . 831 BONITA RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ MCDANIEL, HARDY J DONOVAN HEATING & AIR 533 MYRA STREET 315 SIXTH AVENUE SOUTH NEPTUNE BEACH FL 322664726 JAX BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/07/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH '00 Seminole Rd Atlantic Back FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOBADDRESS:__,;�� l PERMT# PROJECT VALUE$ 3600 NEW AIR CONDITIONING&HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Pm Unit Heat Urtalw BTUs Per Unit.� Seer Rating Duct Systems: T REQZ� P"11ACEMENT AIR CONDITIONING&HEATING SYSTEM INSTALLATION Air Coaffitioning.- Unit Quantity Tons Per Unit ?, S ARI#-367-q5,Y69 Heat Unit Quantity BTLPs Per Unit' - REQUMM Duct Systems: Total CFM ZZ 000 SeerRatizw .-.B REQUMED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of phins) Fire Standpipe (Requhw 3 sets of phtus) Underground Fire Main ?='y Requires 3 sets of phms) Fire Hose Cabinets Quantity Commacial Hoods quantity (Requirles 3 sets of Pk=) Fire Suppression Systems Quan* (Requires 3 au of ph=) (Requires 3 sets of phm) FIREPLACES MISCELLANEOUS: Prefilbricated Fireplace Qty Gas Piping Outlets Automobile Lifts Boilers BTU's Elcvatori���rs ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets #Vertted Wall Furnaces Refri Condenser BM7s #Water Heaters Solar Collection Systems Tanks(gallons) Wefts OTHER: Permit becomes Vold if work d=—not: imesice within a six period or work is suspended or abandoned for six—month&I hereby cmiW I have read &is application and 1=w the Sam to be Mw and COMM All provisions of Im and ordinances BOYMIng this work will be complied with that 3r noL The permit does not gin authority to violate the, whedierspuffied — provisions of any other state or local law regulation construction or the Paftmance ofconshuction. Droperty Ovvners Name MC Dan le Phone Number -7VI-37#!�-- Aechanical Company 'Ll-viove.A oVc.+ �o.Address: '91S- Lit5l ,,qLCt� s, —Office Phone �Z-'l(-3)!TFm(.7,9]-3-79Y- Acense EWder(Print).- wAVZA-w� PanovaN city 0 GA�Uck -Statec zip StateCw6ficafio&Regisftafion# kroftrized S4wahwe ofLkense Holder 1, ,i��/— --- S and subscribed before me this day of -:r 8 1 L/, _20a_ F idol State of 10. state of Florida of Notwy Public Lee Hughes IS Lee Hughe IS 8 278 ')I,!niSSi0n EE 186278 0111; 04)03/20iS anal CERTIFIED,.. www.ahridirectory.org �J Ceftificate of Product Ratings AHRI Certified Reference Number: 3874548 Date: 7/11/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: N4H33OCKA* Indoor Unit Model Number: FEM4P30**A* Manufacturer: TEMPSTAR Trade/Brand name: 13 SEER N SERIES R410A HP Manufacturer responsible for the rating of this system combination is TEMPSTAR Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 30000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F 30000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 19400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accornpanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(3)listed on this Certificate.AHRI expressly disclaims all liability for damages Of any kind arising out of the Use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the users individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "IMP, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on ANOU ON ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129864937845676558 Job- wrightsoft. Project Summary DW*. Mar 22,2012 Enfire House By: Aaron Thacker Donovan Heat&Air 315 Gin Avo 5,Jrx*wwPn nearfi,PL 32230 PhM.-q04-241-3M Par 004-241-3745 EfrkR imonadonoverm.cm Web:www.0onwiafiAC.CW Project Information For: Joe McDaniel 831 Bonita Rd,Atlantic Beach, FL 32233 Notes: Design Information Wedher: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 aF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 20 OF Daily range L Relative humidity 50 % cliftrPrice 53 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11282 Btuh Structure 15282 Btuh Ducts 3353 Btuh Ducts 4753 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Stuh Blower 0 Btuh Piping 0 Btuh Equipment load 14636 Btuh Use manufadurer's data n Ratelswing multiplier 1.00 infiltration Equipment sensible load 20015 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Avers Fireplaces, geo Structure 2253 Stuh Ducts 1014 Stuh Heatin Co I' Central vent(0 cfm) 0 Btuh Area W) 132V 010 Equipment Istent load 3287 Btuh Vdume(fe) 11916 11916 Air chan;m/hour 0.45 0.23 Equipment total load 23282 Btuh Equiv�AVF(cfm) 89 46 Req. total caMcity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 13 SEER N SERIES R410A HP Trade 13 SEER N SERIES R410A HP Model N4H33OCKA* Cond N4H33OCKA* AHRI ref n0357454$ coil FEMV30"A* AHRI ref nc3874548 Effickney 8 HSPF Efficiency 11.0 EER, 13 SEER Heating inpuit Sensible cooling 21000 Stuh Heating o0put 30000 Btuh @ 47OF Latent cooling 9WO Stuh Temperature rise 27 OF Total cooling 30000 Btuh Actuivil air flow 1000 cfm Actual air fIbw 1000 cfm Air flow factor 0.068 cfm1Btuh Air flow factor 0.050 cfrn/Btuh Staitic pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensibIe heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Mantial J 8th Ed. 2012-AN-11 10:38!09 vvr1ghtS0fV Right-&00 Urftersal 8.0.24 RSU06995 Page I �lft c:%user�kowneADOCUMenIRkWdghtodt HVAC%19ogus 2.5 ton.rup GAic m we Front Door fates: E