Permit Mech 2326 Fiddlers Ln 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00000888 Date 7/13/12
Property Address . . . . . . 2326 FIDDLERS LN
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
BACHISTA, KERRY & LEANDRA S TROPIC HEATING & AIR
2326 FIDDLERS LANE 750 MAYPORT RD
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 241-1788
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 107 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/09/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 107 . 00 107 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 111 . 00 111 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JoB ADDRESS: Fc1d(eI(s L.,
PERMIT#
PROJECTVALUES &i'o0'00
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI
Air Conditioning: Unit Quantity Tons Per Unit REQUIRED
Heat: Unit Quantity BTU's Per Unit ial4a..l eer Ratina 16, 0
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Reffigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within.a six month penod or work is suTended or abandoned for six months.I hereby certify that I 7e=ead
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. 'fhe permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name (7 1, 5 PhoneNumber
Mechanical Company r�-o le",— 41�J Office Phone 9-V f-f 7ff Fax Z V z-
# 1901/
Co. Addressi city State 74�� Zip
/-" Ncoeiz4v
License Holder(Print): 0�Pyr�%V-- State Certification/Registration#��Ti
Notarized Signature ofLicense I-Iolder
ribed bef re me this
Swornands scrib beforemethis �1,27
1 KAREN E.PANTFOEDER day of J141V 20 LL
" )NOTARY PUBLIC Signature of Notary Publi
STATE OF FLORIDA
COMM#EE064448
ExPlres 3/4/2015
This combination qualifies for a Federal Energy
'a
Efficiency Tax Credit when placed in service
0,
J.,
between Feb 17,2009 and Dec 31,2011.f
kn�a,S-
*4, fA a
C te
AHRI Certified Reference Number: 3495352 Date: 7/12/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
81 Outdoor Unit Model Number: 226ANA048-A
Indoor Unit Model Number: FV4CN(B,F)005
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: LEGACY 16 PURON HP
i manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
i SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
p, party testing:
Cooling Capacity(Btuh): 47000
EER Rating(Cooling): 12.50
SEER Rating (Cooling): 16.00
Heating Capacity(Btuh)@ 47 F: 48000
Region IV HSPF Rating (Heating): 9.10
W
Heating Capacity(Btuh) 17 F: 29400
fg,
� R
it
U
ai�ale-i,k reNWI 0�
Jata mes-acm,�PI�med wfl,a"AAS,W��, rlld�cotes an nvciwltar�je�ate
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assurnes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe p uct(s),or the
unauthorized alteration of data listed on this Certificate-Certified ratings are valid only for models and configurations listed in the directory at I rod
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI,This Certificate shall only be used for individual,personal and confidentiai reference pufWses. I
The contents of this Certificate may not,in whole or in pin,be reproduced;copied;disserninated;entered into a computer database-or ottiptwise utilized,in any
form or n-onner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION 0
tion for the model cited on this certificate ran be verified at
The informa
W
on
th�e
ertificate was issued,which is listed above,and the Certificate No.,wh ch is I Ste
I k link and enter the AHRI Certified Reference Number a nd the date on ar"114J,0w w,
d below.
@20112 Air-Condilioning.Heating, and Refrigeration Institute CERTIFICATE NO.: 129865934576788992
............
------------ WM.N..
Project Summary Job: Diaz
Entire House Date: 7/12/2012
By:
km*a cut"sy0ft
AL
Chris Diaz, I ropic Heating&Air Conditioning
2326 Fiddlers Ln.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Notes: Email:Tropicac@msn.com
11111�11 III �I Jill" !III!ill!1 V III
Now
Weather. jacksonviiie;iufaig, riL, U
Winter Design Conditions Summer Design Conditions
Outside db 35 T Outside db 91 T
Inside c1b 70 T lnsid�db 75 T
Design TD 35 T Design TD 16 T
Daily range M
Relative humidity 50 %
M.olstuiie 53 gil*;b
Heating Summary Sensible Cooling Equipment Load Sizing
Strurturp 59376 J Strunturp. 34408 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cll 0 Btuh Central vent(0 cfm) 0 Btuh
Humidific-�ation n ettjh 0 Btuh
Piping 0 Btuh
64ulpillulli iudu,
'J'Vo/U i3iui i 66t:mai'luiciuLuit"�UO.to Y
L
Infiltration Equipment sensible load 34408 Btuh
Mathnfl
�qimnjifiari I ft4i JI^
Fireplaces -0 Structure 2601 Btuh
i7"it 1s; n Pzt(Il
Heating Cooling Central vent(0 cfm) 0 Btuh
Air chankiesihour 0)3'
ic,;1d
Equiv. t,'4,Vf- ,Ullri
�0.di i,�zipdu, d L IJ I-
HY
Heatino innut
coolilng
Right-A) Worksheet Job: Diaz
Entire House Date: 7/12/2012
By:
AL
j1 Room na:,me Entire H First Floor
'm ne :
2 Exposed wall 230 0 ouse
oo 7
3 Room height 230.0 ft
Z_ I_
4 9,0 ft d 9,0 ft heat/cool
Room dimo.nsions
5Room area 2325,0 ft' 2325 0 ft2 10 x 2325,0 ft
Ty I Construction U-v lue Or HTM Area (f t2) Load Area (f t') Load
number (Btuhaffl:2�--F) (8t"h/ftl or perimeter (ft) (8tUh) or perimeter (ft) (Btu h)
——.—. Heat Cool Gross Heat Cooll G ross N/P/S Heat Cool
6 12B-0sw 0.097 In 3.36 2,61 540 1 454 1525 1185 540 454 1525 1185
1D-c2 0570 n 1972 1561 54 0 1068 846 54 0 1068 846
11DO 0390 In 1349 11,43 32 32 425 360 32 32 425 360
2B-Orw 0,097 e 3.36 2.61 495 446 1496 1163 495 446 1496 1163
11D-c2ow 0570 e 1972 4665 49 0 970 2303 49 0 970 2303
213-0sw O�097 s 3,36 2,61 540 486 631 1268 540 486 1631 1268
t--.G 1'D-c2ow 0570 Is 1972 1916 54 0 11068 1038 54 0 1068 1038
2B-0sw 0.097 w 336 2,61 495 446 1496 1163 495 446 1496 1163
11 D c2ow 0,570 w 1972 4685 49 0 970 2303 49 0 970 2303
C 16C-30al 0032 1.11 1,37 2325 2325 2574 3184 2325 2325 2574 3184
F 20P-Ot 0521 1803 667 2325 2325 41912 15505 2325 2325 41912 15505
1 61 c)AED excursion I DI - I 1 01
Envelope loss/gain T 5-51351 1 551351 303191
12 a) Infiltration 4241 999 4241 999
b) Room�entilation 0 0 01 0
13 Internal gains Occupants @9 2-10 3 690 3 690
Applianceslother 2400 2400
Subtotal(lines 6 to 13) 59376 34408
-59976 94409
Less external load 0 0
Less transter
Redistr;butIon 0 0 0 0
L14 Subtotal 0 0 0 0
Duct loads 59376 34408 59376 34408
-0% 0%
1%
0% 0 0 a: 0 0
Total room load I --IJ376 344081 1 593761 344
Air required(cfm) 1566 0 1566
OP
Calculations a2proved by ACCA to meet all reguirements of Manual J 8th Ed.
2012-Jul-1 2 10 13 14
Right-Surte4D Universal 2012 12.0,09 Right Jill)Wbile
CkWNDOWS\TEMP�wstmp\eeb253ac-lOb6-4ad8-aad5-12aa28dl2O4a,rup Calc=MJ8 FrontDoorfaces E Page I
Component Constructions Job: Diaz
L Entire House Date: 7/12/2012
=9 By:
C-64 SYW-
AL
oil
For: Chris Diaz, Tropic Heating&Air Conditioning
2326 Fiddlers Ln.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature (*F) 70 75
Elevation: 43 ft Design TD('F) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(grAb) 8.4 52.8
Dry bul b('F) 35 91 Infiltration:
Daily range(oF) - 17 M Method Simplified
V%btbulb('F) - 77 Construction quality Average
\Mnd speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain
ft, Bh-hff-'F f?-'F/Btuh BbjhM2 Btuh Btuh/ft' Btuh
Walls
1213-0sw:Frm wall,vnl ext,r-1 1 cav ins,1/2'gypsum board int n 454 0.097 11.0 3.36 1525 2.61 1185
fnsh,2N4"wood frm e 446 0.097 11.0 336 1496 2.61 1163
s 486 O�097 11.0 336 1631 2.61 1268
W 446 0.097 11.0 3.36 1496 2.61 1163
all 1832 OM7 11.0 3.36 6148 2.61 4780
Partitions
(none)
Windows
1 D-c2ow:2 glazing,cir outr,air gas,wd frm mat,cir innr,1/4"gap, n 54 0.570 0 19.7 1068 15.6 846
1/8"thk;50% blinds 45*,medium;50%outdoor insect screen e 49 0.570 0 19.7 970 46.8 2303
s 54 0.570 0 197 1068 19.2 1038
W 49 0.570 0 19.7 970 46.8 2303
all 207 0,570 0 19.7 4076 31.4 6490
Doors
11 DO:Door,wd sc type n 32 0,390 0 13.5 425 11.4 360
Ceilings
16C-30al:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2' 2325 0.032 30.0 1.11 2574 1.37 3184
gypsum board int fnsh
Floors
20P-0t:Fir floor,wd fir, 1"thkns,tile fir fnsh,amb ovr 2325 0.521 0 18.0 41912 6.67 15505
2012-Jul-1210:13:15
+ wrightSOft Rig ht-Su ite4li U nry ersal 2012 12 0 09 Right J(&Mobile Page 1
C�WINDOWS\TEMP\wstmp�eeb253ac-10b(3�4ad8-aad5-12aa2W204a rup Calc MJ8 Front Door faces E
Al
R
'M
ED Assessment Job: Diaz
Entire House Date: 7/12/2012
Coolft sylum By:
AL
I
For: Chris Diaz, Tropic Heating&Air Conditioning
2326 Fiddlers Ln.,Atlantic Beach, FL 32233
Phone, 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
Location:
Jacksonville/Craig, FL, US Indoor: Heating Cooling
Elevation.- 43 ft Indoor temperature('F) 70 75
Latitude: 30'N Design TD('F) 35 16
Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(grAb) 8.4 52.8
Dry bul b('F) 35 91 Infiftration:
Daily range('F) - 17 M
Wetbulb('F) 77
Wind speed(mph) 15�O T5
will -------
M=M=MM=E=MM==w
Hourly Glazing Load
10,00
9,00
8,00
7,00 ---------
6,00
5,00
4,00
3,00
2,00
1,00
0
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
Ftuiy Aerage AEDfirrit
Maximum hourly glazing load exceeds average by 19.3%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AIED excursion: 0 Eltuh
-ki
rr- wrightsoft Right-Surte,10 Universal 201212 0 09 Right,*Ni 2012-Jul-1210:13:15
C:WNDOVVS\TEMP�wstmp�eeb253ac-lOb6-4ad8-aad5-12aa28dl2G4a.rup Calc=MJ8 FrontDoorfaces E Page I