Loading...
Permit Mech 850 Sailfish 2012 1r 5 f $: , � ' ` CITY OF ATLANTIC BEACH j 800 N ROAD j ",' s . ATLANTIC BEACH, FL 32233 INSPECTION PHONE SEMI LINE OLE 247 -5814 ,, Application Number 12- 00000904 Date 7/18/12 Property Address 850 SAILFISH DR Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 cu 1 ahu Owner Contractor GREEN, ELENA L HUXHAM HEATING & AIR 850 SAILFISH DR E 2101 FLORIDA BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 246 -6721 Permit MECHANICAL HVAC PERMIT Additional desc . Permit Fee . . . 91.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 1/14/13 Other Fees STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 91.00 91.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 95.00 95.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: 0 SA , \ V ` s ( Oa- PERMIT # PROJECT VALUE $ `7 0 0 m ' ARI # y o L/ S' -S & REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit o . Heat: Unit Quantity j BTU's Per Unita , 000 Seer Rating 1 3 Duct Systems: Total CFM r REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators /Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Welts OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 6-S1h/ Phone Number Mechanical Company v yri//a- 7% s A / 1 r2 j , Office Phone- 7a / Fax Co. Address: g10 r 7 / „23JA (6 )v City State F/ Zip 39, License Holder (Print): dhlw",..t5 ��, t61 State Certification/Registration # (ACOS78 Notarized Signature of License Hold: J / Aft > � EB OR A NM ANDAWHTh k won and subscribed before m- t; is /‘ d. o � � 20% l et # EE 057349 1 s, ”` M p1pES : May 21,'01' t gnature of Nota P ubli�� _ ■ , `' ,,,„,,, F zj e ?°j g d ed ThrU de - t t Project Summary Job: 71712 Date: Jul 17, 2012 Entire House By: ERIN RODRIGUEZ Pro Information For. GREEN 850 SAILFISH DRIVE, ATLANTIC BEACH, FL 32233 Notes: HUXHAM - NC CHANGE OUT Desi • n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 76 °F Design TD 29 °F Design TD 16 °F Daily range L Relative humidity 50 % �o Moisture difference 56 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 12301 Btuh Structure 11200 Btuh Ducts 2583 Btuh Ducts 3673 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14884 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible Toad 14427 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1539 Btuh Ducts 902 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft 975 975 Equipment latent Toad 2441 Btuh Volume (ft 7800 7800 Air changes /hour 0.45 0.23 Equipment total load 16868 Btuh Equiv. AVF (cfm) 59 30 Req. total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade 13 SEER Trade 13 SEER Model GSZ13024 Cond GSZ13024 AHRI ref no4248569 Coil ASPF1830 AHRI ref no.4248569 Efficiency 7.7 HSPF Efficiency 11.6 EER, 13 SEER Heating input Sensible cooling 14062 Btuh Heating 19988 Btuh © 47 °F Latent cooling 6026 Btuh Temperature rise 27 °F Total cooling 20088 Btuh Actual air flow 670 cfm Actual air flow 670 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.045 cfm /Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012-Jul-18 08:36:52 !�� -4 wrightsoft° Right Suite® Universal 2012 12.0.07 RSU01508 Page 1 AL,(P. C : \ User& erinlDocuments\ Wrightsoft HVAC \Template\GREEN.rup CaIc = MJ8 Front Door faces: N AI9R CERTIFIEDTM www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4248569 Date: 7/18/2012 Product: Split System: Heat Pump with Remote Outdoor Unit - Air - Source Outdoor Unit Model Number: GSZ130241B* Indoor Unit Model Number: ASPF183016E* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade /Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240 -2008 for Unitary Air- Conditioning and Air- Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Btuh): 24000 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh) @ 47 F: 22800 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh) @ 17 F: 13200 * Ratings followed by an asterisk ( *) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.o Air - Conditioning, Heating, click on Verify Certificate" link and enter the AHRI Certified Reference Number and the date on Aria 11111 a s and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2012 Air - Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129870932153145437