2279 Seminole Rd Unit 9 2012 mech CIT'y OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00000959 Date 7/26/12
Property Address . . . . . . 2279 SEMINOLE RD UNIT 009
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
GIVENS, STEPHEN/DONNA TROPIC HEATING & AIR
2279 SEMINOLE RD. #09 750 MAYPORT RD
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 241-1788
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/22/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STAqE MECH DCA SURCHARGE 2 . 00
STA7E MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Eaid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
i��
MECHANICAL PERMIT PPLICATION
CITY OF ATLANTI,-- BEACH
800 Seminole Rd Atlantic Be tch, FL 3 223 3
Ph(904) 247-5826 Fax(90,�) 247-5845
JOB ADDRESS: C;�a:j� S r-
--�= � PERMIT#
PROJECTVALUE $—
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit �
Heat: Unit Quantity BTU's Per Un t Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATIN SYSTEM INSTALLATION
ARI# 3 6777 y5'X
Air Conditioning: Unit Quantity Tons Per Unit REQUIRED
Heat: Unit Quantity I BTU's Per Un 3 0C.-O Seer Rating /-5-5"
Duct Systems: Total CFM REQUI-RED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Autom bile Lifts
Gas Piping Outlets Boilers BTU's
Elevatcrs/Escalators
ALL OTHER GAS PIPING Heat Eichanger
Quantity of Outlets Pumps
Vented Wall Furnaces Reffige-ator Condenser BTU's
Water Heaters Solar C DIlection Systems
Tanks (gallons)
OTHER: Wells
Permit becomes void if work does not commence within a six month period or w'okt,m,pended or abaridoned for six months.I hereby certify that I h�awred
this application and know the same to be true and correct All provisions of laws and ordiiiances governing this work will be complied with whether specified
ornot. Ihe permit does not give authority to violate the provisions of any other state or Ic I law regulation construction or the performance of construction.
Property Owners Name -PhoneNumber.-
Mechanical Company Office Phonel;�-qfj' h+ Fax,)q �'U
--7Qn- Zip S223
Co. Address: City
A, State F
License Holder(Print): State Certification/Registration
-)NNotanzed Signature ofLicense Holder , %DYZ- ,
KAREN E.PANTFOEDER Sworn and subscribed before mo this day of a, 20 )'z
NOTARY PUBLIC
Signature of Notary Public 4,
STATE OF FLORIDA
Comm#EE064"S
Expires 3/4/2015
This combination qualifies for a Federal Energy
MR,
Efficiency Tax Credit when placed in service.,,`,,,,
between Feb 17,2009 and Dec 31,2011.,,
AHRI Certified Reference Number: 3677458 Date: 7/25/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-J Lir-Source
Outdoor Unit Model Number:225BNA024A
Indoor Unit Model Number: FV4CNF002
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: PREFERRED 15 PURON SINGLE STAGE H P
Manufacturer responsible for the rating of this system combin tion is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-21108 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
23800
Cooling Capacity(13tuh):
EER Rating(Cooling): 12.50
SEER Rating(Cooling): 15.50
Heating Capacity(Btuh)@ 47 F: 24000
Region IV HSPF Rating(Heating): 9.00*
Heating Capacity(Btuh) 17 F: 14500
V
-a WAS;which indicates art r., Junta t
6 Ratings fDilowed by an asterisk indicate a'voluntary nerate of pieviclus?v published data unless acr(rrPanied with 0 r� eta E,
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressfy disclaims all liability for damages of ar ir kind arising out of the use or performance ofthe product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for s and configurations listed in the direc"at
TERMS AND CONDITIONS
This Ceirtificate and its contents are proprietary products of AHRI.This Certificate shall only b4 used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disserninded;entered into a computer database;or otherwise utilized,in any
form or manner or by arry means,except for the user's individual,personal and confidential re erence,
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at
click on link and enter the AHRI Certified Reference Number and the date I
* i,"I ""1 10
which the certificate was issued,which is listed above,and the Certificate No.,which is listed b
t @2012 Air-Conditioning,Heating, and Refrigeration institute CERTIFICATE NO.: 129877120649051477
'0*1
k
Job: Givens
Right J@ Mobile Report Date: 712512012
4= Entire House By:
AL
For: Stephen Givens,Tropic Heating&Air Con clitioning Inc.
2279 Seminole Rd.#9,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax:904-241-2172
Email:Tropicac@msn.com
Location: Indo I Heating Cooling
Jacksonville/Craig, FL, US lndl,'Dr temperature('F) 70 75
; i
Elevation: 43 ft De gn TD(*F) 35 16
Latitude: 30'N Re tive humidity(%) 30 50
s
Outdoor: Heating Cooling M sture difference(grAb) 8.4 52.8
Dry bul b('F) 35 91 Infilt tion:
Daily range(*F) - 17 M Me hod Simplified
Wetbulb('F) - 77 Co istruction quality Average
Wind speed(mph) 15.0 7.5 FirelAaces 0
Component Btuhff Btuh %of load
Walls 3.4 3808 26.2
Glazing 19.7 2547 17�5 VWs
Doors 13.5 433 3.0
Ceilings 2.4 2441 16.8
Floors 0 0 0
Infiltration 2.0 2586 17.8
Ducts 2711 181
Piping 0 0
Humidification 0 0 D=S Offlirgs
Ventilation 0 0
Adjustments 0
Total 14527, 100.0
M Z-V
Component Btu hfil? Btuh %of load
Walls 1.5 1706 11.3 WAIS 1.to, Gains
Glazing 36.2 4674 30.8
Doors 11.4 367 2.4
Ceilings 3.0 3020 19.9
Floors 0 0 0 Ducts
Infiltration 0.5 623 4.1 3a2irg—
Ducts 3111 20.5
Ventilation 0 0
Internal gains 1660 10.9 Inf iltraltion
Blower 0 0 1
Adjustments 0 D=s Geilirgs
Total 15161 , 100.0,
Latent Cooling Load 1967 Btuh
Overall U-value=0.081 Btuh/fF-'F
Data entries checked.
2012-Jul-25 10:03*12
1;1� + wrightsoft Right-Suitedl)Universal 2012 12.0.09 Right AD Mobile Page 1
C:XWNDOWSATEMPkwsbmX256OlObO-62fa-4f5d-a74d-ObdgccaIO73.rup Calc=MJ8 FrontDcrfaces: S
I
Job: Givens
Project Summary Date: 7/25/20`12
Entire House By:
AL
For: Stephen Givens, Tropic Heating&Air Conditioning!Inc.
22-19 Seminole Rd.#9, Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax:904-241-2, 72
Email:Tropicac@msn.com
Notes.-
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 *F Outside db 91 *F
Inside db 70 'F Inside db 75 *F
Design TD 35 *F Desigii TD 16 'F
Daily iange M
Relative humidity 50 %
MlDiStt.�re difference 53 grAb
Heating Summary Stsible Cooling Equipment Load Sizing
Structure 11816 Btuh Struct ire 12049 Btuh
Ducts 2711 Btuh Ducts 3111 Btuh
Central vent(0 dm) 0 Btuh Centr,il vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blowe, 0 Btuh
Piping 0 Btuh
Equipment load 14527 Btuh Use rr anufacturer's data y
Rate/�vAng multiplier 1.00
Infiltration Equipi nent sensible load 15161 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Struct ire 1647 Btuh
Ducts 320 Btuh
Heattin Cooling Centri il vent(0 dm) 0 Btuh
Area(ft2) 1 00g 1008 Equip nent latent load 1967 Btuh
\VbIume(ft") 9072 9072
Air changes/hour 0.45 0.23 Equip nent total load 17128 Btuh
'�quiv.AVF(cfm) 68 35 Req.. al capacity at 0.70 SHR 1.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make
Trade n/a Trade
Model n/a Cond
AHRI ref n/a coil
AHRI 'ef
Efficiency n/a EfficiE ncy 0 SEER
Heating input 0 Btuh Sensi Ae cooling 0 Btuh
Heating output 0 Btuh Laten cooling 0 Btuh
Temperature rise 0 *F Total =Iing 0 Btuh
Actual air flow 0 cfrn Actua airflow 669 cfm
Air flow factor 0 cfm/Btuh Air flo,v factor 0.044 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Loadsensible heat ratio 0.89
Calculations approved by ACCA to meet all recluirements of Manual J 8th Ed.
2012-Jul-25 10:03:12
+ wrigh1t50ft Right-SuiteO Universal 2012 12�0.09 Right AD Mobile Pagel
C:%%MNDOWSkTEAARwsbwL)56OlObO-62fa-4f5d-a74d-ObdgccafD73.rup Calc=MJ8 Front D r faces: S
Right-A)Worksheet Job: Givens
Entire House Date: 7/25/2012
By:
AL
1 Room name Entir House First Floo,
2 Exposed wall 11"o ft 144.0 ft
3 Room height 9-0 It d 9.0 ft heatf000l
4 Room dime ns 10 x 1008.0 ft
5 Room area 10080 ft2 1008.0 ft'
I
Ty I Construction LI-value Or HTM Area (f t1) Load Area (f t) Load
number Btuh/ft2-'F) (Bt uh/f tj or perimeter (ft) (Btuh) or perimeter (ft) (Btu h)
Heat cool Gross NfP/S cool Gross N/P/S Heat Cool
6 V" 12B-Obw 0097 n 3.36 150 432 1304 584 432 389 1304 584
I D-c2ow O�570 n 19.72 2091 43 855 906 43 0 855 906
128-Obw 0.097 e 3.36 150 216 1 652 292 216 194 652 292
1 D-c2ow 0.570 e 19.72 63.01 22 427 1365 22 0 427 1365
11 V" 12B-Otrw 0.097 s 336 1.50 432 1304 584 432 389 1304 584
1D-c2ow 0,570 s 1972 25.16 43 855 1090 43 0 855 1090
1 213-0bw 0,097 w 336 150 216 1 547 245 216 163 547 245
'D-c2ow 0.570 w 19.72 63.01 21 1 411 1313 21 0 411 1313
11D0 0'390 w 13'49 1143 32 3: 433 367 32 32 433 367
C 16C-13al 0,070 2.42 3.00 1006 10(m 2441 3020 1008 1008 2441 3020
F Florl 0.000 0.00 0.00 1008 1 OOE 0 0 1008 1008 0 0
61 c)AED excursion 01 0
1 Envelope loss/gain 92-301 97671 1 1 92301 97�137
12 a) Infiltration 2586 623 2586 623
b) Room ventilation 0 0 0 0
13 Internal gains: Oocupants 230 2 460 2 460
Appliancestother 1200 1200
Subtotal(lines 6 to 13) 11816 12D49 11816 12049
Less external 11 d 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 11816 12049 11816 12049
15 Duct loads 23% 289 2711 3111 23% 26% 2711 3111
1 Total room load 145271 151611 1 1 145271 151611
Air required(cfrn) 0 689 0 669
Calculations approved by ACCA to meet all recluirements of Manual J 8th Ed.
414- wwriShriscift 2012-Jul-25 10iO3:12
4 Right-Suiteill)Universal 2012 12.0.09 Right 141)Mobile Page I
C:kWNDOVvS%TEMMvstmpM6OlObO-62fa-4F-,d-a74d-ObdgocafO73.rup Calc=MJ8 FrontDorfaces: S
Job: Givens
4=3 Component Constructions Date: 7125/2012
Entire House By:
VA"a C""Sift"
AL
For: Stephen Givens,Tropic Heating&Air Cor�clitioning!Inc.
2279 Seminole Rd.#9,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax:904-241-217��
Email:Tropicac@msn.com
Location: Indo r: Heating Cooling
Jacksonville/Craig, FL, US In r temperature(oF) 70 75
Elevation: 43 ft ign TD(*F) 35 16
Latitude: 30oN R ative humidity 30 50
Outdoor: Heating Cooling Moisture difference(grft) 8.4 52.8
Dry bul b('F) 35 91 Infiftiation:
Daily range(*F) - 17 M M(thod Simplified
Watbulb('F) - 77 Cc nstruction quality Average
Wind speed(mph) 15.0 7.5 Fir Dplaces 0
NOMINNO lownwmxmmwmnwm
Construction descriptions Or Area nsul R Htg HTM Loss Clg HTM Gain
fe I BWff-'F ft-'FA3kti Blitiff Btuh WIN Btuh
Walls
12B-Obw:Frm wall,brk 4"ext,r-1 1 cav ins,112"gypsum board int n 389 0.097 11.0 3.36 1304 1.50 584
fnsh,2"x4"wood frm e 194 0.097 11.0 3.36 652 1.50 292
S 389 0.097 11.0 3.36 1304 1.50 584
W 163 0.097 11.0 3.36 547 1.50 245
all 1135 0.097 11.0 3,36 3808 1.50 1706
Partitions
(none)
Windows
I D-c2ow:2 glazing,cir outr,air gas,wd frm mat,dr innr,1/4"gap, n 43 0.570 0 19.7 855 20.9 906
1/8"thk e 22 0.570 0 19.7 427 63.0 1365
S 43 0,570 0 197 855 25,2 1090
W 21 0.570 0 19.7 411 63.0 1313
all 129 0.570 0 19.7 2547 36.2 4674
Doors
11 DO:Door,vid sc type W 32 0.390 0 13.5 433 11.4 367
Ceilings �j
16C-1 3al:Attic ceiling,asphalt shingles roof mat,r-1 3 ceil ins,1/2" 1008 0.070 13.0 2.42 2441 3.00 3020
gypsum board int fnsh
Floors
Florl:Florl 1008 0 0 0 0 0 0
2012-Jul-25 10:03:12
+ wrightSIDIft Right-SiikeGi Unwersal 201212,0.09 Right JO Mobile Page I
C:XWNDOWSkTEMPW&-tmp%256OlObO-62fa-4f5d-a74d-Obd9ceafD73.rup Calc=MJ8 Front Dorfaces: S