Loading...
2279 Seminole Rd Unit 9 2012 mech CIT'y OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00000959 Date 7/26/12 Property Address . . . . . . 2279 SEMINOLE RD UNIT 009 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ GIVENS, STEPHEN/DONNA TROPIC HEATING & AIR 2279 SEMINOLE RD. #09 750 MAYPORT RD ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/22/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STAqE MECH DCA SURCHARGE 2 . 00 STA7E MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Eaid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. i�� MECHANICAL PERMIT PPLICATION CITY OF ATLANTI,-- BEACH 800 Seminole Rd Atlantic Be tch, FL 3 223 3 Ph(904) 247-5826 Fax(90,�) 247-5845 JOB ADDRESS: C;�a:j� S r- --�= � PERMIT# PROJECTVALUE $— NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit � Heat: Unit Quantity BTU's Per Un t Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATIN SYSTEM INSTALLATION ARI# 3 6777 y5'X Air Conditioning: Unit Quantity Tons Per Unit REQUIRED Heat: Unit Quantity I BTU's Per Un 3 0C.-O Seer Rating /-5-5" Duct Systems: Total CFM REQUI-RED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Autom bile Lifts Gas Piping Outlets Boilers BTU's Elevatcrs/Escalators ALL OTHER GAS PIPING Heat Eichanger Quantity of Outlets Pumps Vented Wall Furnaces Reffige-ator Condenser BTU's Water Heaters Solar C DIlection Systems Tanks (gallons) OTHER: Wells Permit becomes void if work does not commence within a six month period or w'okt,m,pended or abaridoned for six months.I hereby certify that I h�awred this application and know the same to be true and correct All provisions of laws and ordiiiances governing this work will be complied with whether specified ornot. Ihe permit does not give authority to violate the provisions of any other state or Ic I law regulation construction or the performance of construction. Property Owners Name -PhoneNumber.- Mechanical Company Office Phonel;�-qfj' h+ Fax,)q �'U --7Qn- Zip S223 Co. Address: City A, State F License Holder(Print): State Certification/Registration -)NNotanzed Signature ofLicense Holder , %DYZ- , KAREN E.PANTFOEDER Sworn and subscribed before mo this day of a, 20 )'z NOTARY PUBLIC Signature of Notary Public 4, STATE OF FLORIDA Comm#EE064"S Expires 3/4/2015 This combination qualifies for a Federal Energy MR, Efficiency Tax Credit when placed in service.,,`,,,, between Feb 17,2009 and Dec 31,2011.,, AHRI Certified Reference Number: 3677458 Date: 7/25/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-J Lir-Source Outdoor Unit Model Number:225BNA024A Indoor Unit Model Number: FV4CNF002 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: PREFERRED 15 PURON SINGLE STAGE H P Manufacturer responsible for the rating of this system combin tion is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-21108 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: 23800 Cooling Capacity(13tuh): EER Rating(Cooling): 12.50 SEER Rating(Cooling): 15.50 Heating Capacity(Btuh)@ 47 F: 24000 Region IV HSPF Rating(Heating): 9.00* Heating Capacity(Btuh) 17 F: 14500 V -a WAS;which indicates art r., Junta t 6 Ratings fDilowed by an asterisk indicate a'voluntary nerate of pieviclus?v published data unless acr(rrPanied with 0 r� eta E, DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressfy disclaims all liability for damages of ar ir kind arising out of the use or performance ofthe product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for s and configurations listed in the direc"at TERMS AND CONDITIONS This Ceirtificate and its contents are proprietary products of AHRI.This Certificate shall only b4 used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disserninded;entered into a computer database;or otherwise utilized,in any form or manner or by arry means,except for the user's individual,personal and confidential re erence, CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at click on link and enter the AHRI Certified Reference Number and the date I * i,"I ""1 10 which the certificate was issued,which is listed above,and the Certificate No.,which is listed b t @2012 Air-Conditioning,Heating, and Refrigeration institute CERTIFICATE NO.: 129877120649051477 '0*1 k Job: Givens Right J@ Mobile Report Date: 712512012 4= Entire House By: AL For: Stephen Givens,Tropic Heating&Air Con clitioning Inc. 2279 Seminole Rd.#9,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com Location: Indo I Heating Cooling Jacksonville/Craig, FL, US lndl,'Dr temperature('F) 70 75 ; i Elevation: 43 ft De gn TD(*F) 35 16 Latitude: 30'N Re tive humidity(%) 30 50 s Outdoor: Heating Cooling M sture difference(grAb) 8.4 52.8 Dry bul b('F) 35 91 Infilt tion: Daily range(*F) - 17 M Me hod Simplified Wetbulb('F) - 77 Co istruction quality Average Wind speed(mph) 15.0 7.5 FirelAaces 0 Component Btuhff Btuh %of load Walls 3.4 3808 26.2 Glazing 19.7 2547 17�5 VWs Doors 13.5 433 3.0 Ceilings 2.4 2441 16.8 Floors 0 0 0 Infiltration 2.0 2586 17.8 Ducts 2711 181 Piping 0 0 Humidification 0 0 D=S Offlirgs Ventilation 0 0 Adjustments 0 Total 14527, 100.0 M Z-V Component Btu hfil? Btuh %of load Walls 1.5 1706 11.3 WAIS 1.to, Gains Glazing 36.2 4674 30.8 Doors 11.4 367 2.4 Ceilings 3.0 3020 19.9 Floors 0 0 0 Ducts Infiltration 0.5 623 4.1 3a2irg— Ducts 3111 20.5 Ventilation 0 0 Internal gains 1660 10.9 Inf iltraltion Blower 0 0 1 Adjustments 0 D=s Geilirgs Total 15161 , 100.0, Latent Cooling Load 1967 Btuh Overall U-value=0.081 Btuh/fF-'F Data entries checked. 2012-Jul-25 10:03*12 1;1� + wrightsoft Right-Suitedl)Universal 2012 12.0.09 Right AD Mobile Page 1 C:XWNDOWSATEMPkwsbmX256OlObO-62fa-4f5d-a74d-ObdgccaIO73.rup Calc=MJ8 FrontDcrfaces: S I Job: Givens Project Summary Date: 7/25/20`12 Entire House By: AL For: Stephen Givens, Tropic Heating&Air Conditioning!Inc. 22-19 Seminole Rd.#9, Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax:904-241-2, 72 Email:Tropicac@msn.com Notes.- Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 *F Outside db 91 *F Inside db 70 'F Inside db 75 *F Design TD 35 *F Desigii TD 16 'F Daily iange M Relative humidity 50 % MlDiStt.�re difference 53 grAb Heating Summary Stsible Cooling Equipment Load Sizing Structure 11816 Btuh Struct ire 12049 Btuh Ducts 2711 Btuh Ducts 3111 Btuh Central vent(0 dm) 0 Btuh Centr,il vent(0 cfm) 0 Btuh Humidification 0 Btuh Blowe, 0 Btuh Piping 0 Btuh Equipment load 14527 Btuh Use rr anufacturer's data y Rate/�vAng multiplier 1.00 Infiltration Equipi nent sensible load 15161 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Struct ire 1647 Btuh Ducts 320 Btuh Heattin Cooling Centri il vent(0 dm) 0 Btuh Area(ft2) 1 00g 1008 Equip nent latent load 1967 Btuh \VbIume(ft") 9072 9072 Air changes/hour 0.45 0.23 Equip nent total load 17128 Btuh '�quiv.AVF(cfm) 68 35 Req.. al capacity at 0.70 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a coil AHRI 'ef Efficiency n/a EfficiE ncy 0 SEER Heating input 0 Btuh Sensi Ae cooling 0 Btuh Heating output 0 Btuh Laten cooling 0 Btuh Temperature rise 0 *F Total =Iing 0 Btuh Actual air flow 0 cfrn Actua airflow 669 cfm Air flow factor 0 cfm/Btuh Air flo,v factor 0.044 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Loadsensible heat ratio 0.89 Calculations approved by ACCA to meet all recluirements of Manual J 8th Ed. 2012-Jul-25 10:03:12 + wrigh1t50ft Right-SuiteO Universal 2012 12�0.09 Right AD Mobile Pagel C:%%MNDOWSkTEAARwsbwL)56OlObO-62fa-4f5d-a74d-ObdgccafD73.rup Calc=MJ8 Front D r faces: S Right-A)Worksheet Job: Givens Entire House Date: 7/25/2012 By: AL 1 Room name Entir House First Floo, 2 Exposed wall 11"o ft 144.0 ft 3 Room height 9-0 It d 9.0 ft heatf000l 4 Room dime ns 10 x 1008.0 ft 5 Room area 10080 ft2 1008.0 ft' I Ty I Construction LI-value Or HTM Area (f t1) Load Area (f t) Load number Btuh/ft2-'F) (Bt uh/f tj or perimeter (ft) (Btuh) or perimeter (ft) (Btu h) Heat cool Gross NfP/S cool Gross N/P/S Heat Cool 6 V" 12B-Obw 0097 n 3.36 150 432 1304 584 432 389 1304 584 I D-c2ow O�570 n 19.72 2091 43 855 906 43 0 855 906 128-Obw 0.097 e 3.36 150 216 1 652 292 216 194 652 292 1 D-c2ow 0.570 e 19.72 63.01 22 427 1365 22 0 427 1365 11 V" 12B-Otrw 0.097 s 336 1.50 432 1304 584 432 389 1304 584 1D-c2ow 0,570 s 1972 25.16 43 855 1090 43 0 855 1090 1 213-0bw 0,097 w 336 150 216 1 547 245 216 163 547 245 'D-c2ow 0.570 w 19.72 63.01 21 1 411 1313 21 0 411 1313 11D0 0'390 w 13'49 1143 32 3: 433 367 32 32 433 367 C 16C-13al 0,070 2.42 3.00 1006 10(m 2441 3020 1008 1008 2441 3020 F Florl 0.000 0.00 0.00 1008 1 OOE 0 0 1008 1008 0 0 61 c)AED excursion 01 0 1 Envelope loss/gain 92-301 97671 1 1 92301 97�137 12 a) Infiltration 2586 623 2586 623 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupants 230 2 460 2 460 Appliancestother 1200 1200 Subtotal(lines 6 to 13) 11816 12D49 11816 12049 Less external 11 d 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 11816 12049 11816 12049 15 Duct loads 23% 289 2711 3111 23% 26% 2711 3111 1 Total room load 145271 151611 1 1 145271 151611 Air required(cfrn) 0 689 0 669 Calculations approved by ACCA to meet all recluirements of Manual J 8th Ed. 414- wwriShriscift 2012-Jul-25 10iO3:12 4 Right-Suiteill)Universal 2012 12.0.09 Right 141)Mobile Page I C:kWNDOVvS%TEMMvstmpM6OlObO-62fa-4F-,d-a74d-ObdgocafO73.rup Calc=MJ8 FrontDorfaces: S Job: Givens 4=3 Component Constructions Date: 7125/2012 Entire House By: VA"a C""Sift" AL For: Stephen Givens,Tropic Heating&Air Cor�clitioning!Inc. 2279 Seminole Rd.#9,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax:904-241-217�� Email:Tropicac@msn.com Location: Indo r: Heating Cooling Jacksonville/Craig, FL, US In r temperature(oF) 70 75 Elevation: 43 ft ign TD(*F) 35 16 Latitude: 30oN R ative humidity 30 50 Outdoor: Heating Cooling Moisture difference(grft) 8.4 52.8 Dry bul b('F) 35 91 Infiftiation: Daily range(*F) - 17 M M(thod Simplified Watbulb('F) - 77 Cc nstruction quality Average Wind speed(mph) 15.0 7.5 Fir Dplaces 0 NOMINNO lownwmxmmwmnwm Construction descriptions Or Area nsul R Htg HTM Loss Clg HTM Gain fe I BWff-'F ft-'FA3kti Blitiff Btuh WIN Btuh Walls 12B-Obw:Frm wall,brk 4"ext,r-1 1 cav ins,112"gypsum board int n 389 0.097 11.0 3.36 1304 1.50 584 fnsh,2"x4"wood frm e 194 0.097 11.0 3.36 652 1.50 292 S 389 0.097 11.0 3.36 1304 1.50 584 W 163 0.097 11.0 3.36 547 1.50 245 all 1135 0.097 11.0 3,36 3808 1.50 1706 Partitions (none) Windows I D-c2ow:2 glazing,cir outr,air gas,wd frm mat,dr innr,1/4"gap, n 43 0.570 0 19.7 855 20.9 906 1/8"thk e 22 0.570 0 19.7 427 63.0 1365 S 43 0,570 0 197 855 25,2 1090 W 21 0.570 0 19.7 411 63.0 1313 all 129 0.570 0 19.7 2547 36.2 4674 Doors 11 DO:Door,vid sc type W 32 0.390 0 13.5 433 11.4 367 Ceilings �j 16C-1 3al:Attic ceiling,asphalt shingles roof mat,r-1 3 ceil ins,1/2" 1008 0.070 13.0 2.42 2441 3.00 3020 gypsum board int fnsh Floors Florl:Florl 1008 0 0 0 0 0 0 2012-Jul-25 10:03:12 + wrightSIDIft Right-SiikeGi Unwersal 201212,0.09 Right JO Mobile Page I C:XWNDOWSkTEMPW&-tmp%256OlObO-62fa-4f5d-a74d-Obd9ceafD73.rup Calc=MJ8 Front Dorfaces: S