Loading...
Permit Mech 1228 Linkside Dr 2012 N ~' rS CITY OF ATLANTIC BEACH s) 800 SEMINOLE ROAD '� - s' ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247 -5814 Application Number 12- 00000978 Date 7/30/12 Property Address 1228 LINKSIDE DR Application type description MECHANICAL HVAC ONLY Property Zoning TO BE UPDATED Application valuation . . . 0 Application desc 1 CU 1 AHU Owner Contractor BERGMAN WILLIAM K AND GWEN M NORTHPORT CONSTRUCTION GROUP 1228 LINKSIDE DR NORTHPORT HGT AND AIR ATLANTIC BEACH FL 322334387 6653 POWERS AVE # 29 JACKSONVILLE FL 32217 (907) 731 -8248 Permit W /W /O MECHANICAL PERMIT Additional desc . Permit Fee . . . 198.00 Plan Check Fee . . .00 Issue Date . . . Valuation . . . . 0 Expiration Date . 1/26/13 Other Fees STATE MECH DCA SURCHARGE 2.97 STATE MECH DBPR SURCHARGE 2.97 Fee summary Charged Paid Credited Due Permit Fee Total 198.00 198.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 5.94 5.94 .00 .00 Grand Total 203.94 203.94 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. I MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247 -5826 Fax (904) 247 -5845 JOB ADDRESS: / a 2 8 L /Nk S/ 0C" nr /9 T L, ry ri C PS C4 322 "b3 PERMIT # PROJECT VALUE $ L/, / 20 ,00 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: ! Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# L/2 ('/9/3 Air Conditioning: Unit Quantity / Tons Per Unit 3 7 0 AI REQUIRED Heat: u n „ a„*;*, , i 0 v v Seer Rating /3 5 C Q Duct Systems: To] REQUIRED FIRE PREVENTION —. 77) ft?? a L Fire Sprinkler System equires 3 sets of lans Fire Standpipe equires 3 sets of pla Underground Fire Main equires 3 sets of plans) Fire Hose Cabinets frroi equires 3 sets of plans) Commercial Hoods equires 3 sets of lans P ) Fire Suppression Systen equires 3 sets of plans) FIRE PLACES kNEOUS: Prefabricated Fireplace t ifts Gas Piping Outlets BTU's ilators ALL OTHER GAS PIP :r Quantity of Outlets # Vented Wall Furnaces ondenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this applicatiorj and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 13 C R 6 r--v/9 N W I LL, / '9 M Phone Number Mechanical Company NORTH PoR r COQ S rR , E r/ oPI C E o vi) Office Phone 339— 32 VS Fax 3 a — 2 2 y 9 Co. Add * " t ” 4;0 t 2 S .41/6 51, 7 6 # 2 9 City JAC /Cs v v: c < < State F- Zip 3 2 2 / 7 Licen# HAP � 5 `>1?)`, sl SPA 2 'l A 1 T> i ! i -mate Certification/Registration # C �"I C 12.5-00?-,5 0l , � Notatized.*Artne:Li&nse Holder N 9 Commisa+on l :' Sworn and sun . ribed before me s •s ' 7 , day of 04 20 /Z E� pF'F��� " / / , ;c O v `� Signature of Notary Public �,rrunnn�t��� 4110 lam : r7.' ti .. �Fti .chzga atlY' • �M•.•••?"'•S Z."�leoT.11 71, Z'..,7.Z'1. ` y 51.51MW7N1,N' .... H ATI G : ND Alp CONOETIONING . 6653 Power Ave, Suite 29 - Jacksonville, Florida 32217 Phone: (904) 731 -8248 - Fax: (904) 731 -8249 wwwJacksonvilieACService.com TracIe]acl onviIIeACService.cam TO: City of Atlantic Beach FROM: Tract L. Collie, Office Manager ATTN: Debbie White PAGES: 2 (Including cover sheet) FAX: (904) 247 -5845 DATE: July 30, 2012 ❑ Urgent ❑ For review ❑ Please comment ❑ Please reply ❑ Please recycle Hi Ms Debbie — Here is the Manual J Load Calculations for 1228 Linkside Drive. I tried to reach you by phone, but there was no answer. I would really like to be able to get you paid right away so that we may finish our install today. Again, thanks for all your help ! ! ! f " =- =^ , „ ... Project Summary • Job: 1228 Linkside Drive r �; , `` ' t j' Entire HouSG Data: 07/30/2042 ti By David C Brown • ,, F N orth Point Heating and Air Conditioning 6653 Powers Ave. Suite 29, Jacksonville, R 32217 Phone: 004) 4.38 -4022 41111M11■11 Pra'ect Information For: 1228 Linkside Drive, Atlantic Beach, FL 32205 Notes; Desi • n Information Weather Jacksonville /Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 =F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 Moisture difference 53 gr /!b Heating Summary Sensible Cooling Equipment Load Sizing Structure 24403 Btuh Structure Ducts 0 Btuh Ducts 25498 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 24403 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 26198 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2698 Btuh Ducts 0 Stub Heating Cooling Central vent (0 cfm) 0 Btuh Area (its) 1626 1626 Equipment latent load 2698 Btuh Volume OF) 15880 15880 Air changes/hour 0.38 0.20 Equipment total Toad 28896 Btuh Equiv. AVF (cfm) 101 53 Req. total capacity at 0.72 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ130363A* Cond GSZ130363A* AHRI ref 5439793 Coil ARUF36C14A* AHRI ref 5439793 Efficiency 8 HSPF Efficiency 11,0 EER, 13 SEER Heating input Sensible cooling 24480 Btuh Heating output 34000 Btuh @ 47°F Latent cooling 9520 Btuh Temperature rise 27 °F Total cooling 34000 Btuh Actual air flow 1133 cfm Actual air flow 1133 efrn Air flow factor 0.046 cfm /Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrightson” Right - Suite* u,iversal 2012 12.0.10 RSU15431 2012-Jul-30 13:17:45 AVV C:1Users1Consulwnoenktop112.28 Unkside Dr 07.30.12.np can = MA Front Door feces: E Page 1 i