125 8th St 2012 HVAC Ss1 CIT' OF ATLANTIC BEACH 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 4533 �� Application Number . . . . . 12-()0000988 Date 8/01/12 Property Address . . . . . . 125 8TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------ Application desc 1 CU 1 AHU --------------------------------------- ------------ Owner Contractor ------------------------ -------------- BRINSON HELEN S HUXHAM HEATING & AIR 125 8TH STREET 2101 FLORIDA BLVD. ATLANTIC BEACH FL 32233 r NEPTUNE BEACH FL 32266 (904) 246-6721 ------------------ Permit . . . . . . MECHANICAL HV C PERMIT Additional desc . . Permit Fee 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/28/13 ------------------------------------------------------ Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. f MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic$each,FL 32233 Ph(904) 247-5826 Fax ( 04)247-5845 JOB ADDRESS: S g S I PERMIT# ROJECT VALUE$_ '/,300 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3 ARI QS Heat: Unit Quantity / BTU's Per ��O Unit y' Seer Ratio DIRE / Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MIS ELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilei s BTU's Eleva ors/Escalators ALL OTHER GAS PIPING Heat .xchanger Quantity of Outlets Pum #Vented Wall Furnaces Refrp erator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is s spended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and o inances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or ocal law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company L} /�� l2 Office Phonegf/(/2��0� Fax Co. Address: Cl © /0 t2 +C)14 &Vj Ci �c State Zi city `Z� � p;f� License Holder(Print): e-5 1 State Certification/Registration# CgCO-S 78'AS Notarized Signature of License Hol er w rn and subscribed before this day of cw, S-r 20 )2- My' SHIA ,. tary D pY M1SS!. kXPI ESLFebru14,rnso e No Pu Rf� 80ndod ary 2014 Thru Notary Pubi c Undenvnters I Ili Project Summary Job: 73112 Date: Jul 31,2012 Entire House By: ERIN RODRIGUEZ i Project • • For: BRINSON 125 8TH STREET,ATLANTIC BE CH, FL 32233 Notes: HUXHAM -A/C CHANGE OUT Design Information i Weather. Jacksonville Mayport Naval, FL, US I Winter Design Conditions Summer Design Conditions Outside db 39 OF Out ide db 92 OF Inside db 68 OF Insice db 76 OF Design TD 29 OF Des gn TD 16 OF Daily range L Rel ive Humidity 50 % Moisture difference 56 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18196 Btuh Structure 17811 Btuh Ducts 5837 Btuh Ducts 8130 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh BI(mer 0 Btuh Piping 0 Btuh Equipment load 24033 Btuh Use jmanufacturer's data n Rated/swing multiplier 0.97 Infiltration Equipment sensible load 25162 Btuh Method Simplified Ll' tent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1736 Btuh Duds 2063 Btuh Heating Cooling Cen ral vent(0 cfm) 0 Btuh Area(ft) 1710 1710 Equipment latent load 3799 Btuh Volume(ft') 13680 13680 Air changes/hour 0.38 0.20 Equi ment total load 28962 Btuh Equiv.AVF (cfm) 87 46 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade XR13 WEATHERTRON Trade XR13 WEATHERTRON Model 4TWR3036B1 Cond 4TWR3036B1 AHRI ref no.4941265 Coil GAT2AOB42S31++TDR AHF I ref no.4941265 Efficiency 8.2 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sen ible cooling 25200 Btuh Heating output 34800 Btuh @ 47°F Late it cooling 10800 Btuh Temperature rise 26 OF Tota cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Stati pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved byACCA to meet all =irements of Manual J 8th Ed. 2012-Jul-31 23:16:09 �.. + wrightsoftm Right-Suite®Universal 2012 12.0.07 RSU01508 Pagel n..r C:1UsersVerinDocuments%WrightsoftHVAOTerplate'BRINSON.rup Calc=MJ8 Front Doorfaoe�:N VIII CERTIFIEDTM Certificate of Produc Rationgs AHRI Certified Reference Number: 4941265 De: 8/1/2012 Product: Split System: Heat Pump with Remote Outdoor Un t-Air-Source Outdoor Unit Model Number: 4TWR3036B1 Indoor Unit Model Number: GAT2AOB42S31+TDR Manufacturer: TRANE Trade/Brand name: XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 36000 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh)@ 47 F: 34800 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh)@ 17 F: 21800 f Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless a companied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representation i,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of ny kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for m dels and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only a used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;dissemi ated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential i eference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.or 3, AAir-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date n SOU ®® '�® which the certificate was issued,which is listed above,and the Certificate No.,which is listed slow. and Refrigeration Institute ©2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129883007096535335 I i