2329 Seminole Rd HVAC 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
2 INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001011 Date 8/03/12
Property Address . . . . . . 2329 SEMINOLE RD
Application type description MECHANICAL HVAC ONLY
Property zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
-------------------------- --------------------------------------------------
Application desc
I cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------
------------------------
KNABB, FRANKIE C. TRUST TROPIC AIRE OF NORTH FLORIDA
3703 ORTEGA BLVD 9969 OLD KINGS ROAD
JACKSONVILLE FL 32210 JACKSONVILLE FL 32219
(904) 719-9600
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 9S . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/30/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
------------------------------------------------------ ----------------------
Fee summary Charged Paid Credited Due
----------------- ---------- --- ------ ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERNII I IS APPRONLD ONLI IN ACCORDANCE %%I I HALL C[T1 OF ATLANTIC OEAC H ORDINAN(ES AND THE FLORIDA
III ILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: 43s5f PERMIT #
PROJECT VALUE $ ARI#
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INVALLATION
Air Conditioning: Unit Quantity_/___ Tons.Per Unit 61t
Heal: Unit Quantity BTU s Per Uni��__ Seer Rating 16E�UIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty— Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
4 Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Perm it becomes sold if%vork does not xom.a.x,, ithin a sr,nionth period or v,ork issuspended or abandoned for six months.I heeb� cmait's that I have read
this application and kbo� the same to be note and correct. Al I pros isimis of laes and ordinance, ,serrir,this mix v,i I I be complied ith hcthc, pe,ifi,d
or not, the perninit does not gike authorit) to violate the provisions of ans other%rate(it local la%% regolation constract ion or the performance of construction
Property Owners Name I:F- K� PhoneNumber
Mechanical Company P\irz-457 —Office Phone—Fax
Co. Address: Ehj) wi"te'; e�. , City J-,P/, Stater–L. Zip '3Z7 19
License Holder(Print): State Certification/Registration# eAC c,,,5,j 3 61
Notarized Signature of License Halderj�::–��l �- \ , I
Sworn and ub ribe efit e this day o Qf.,S7-- 20_)Zm
r, P
Signature ®r"otary Public
DesignStar Load Calculation
Results are intended for use with Rheem heating and cooling systems only
T N— "e, - I
�Customer Information
7xatlon:
Street Add ress 2329 seminole road, DUVAL, FL 32233
Latitude, Longitude 30.33750, -81.768,50
House Square Footage: 1120 sq. ft.
Name: FRANKIE KNABB
Phone:
Email:
Design Conditions
Outdoor eating Coolin;
Dry bulb ('F) 32 93
Daily range M
Relative humidity 50%
Moisture difference 53
Indoor Heating Cooling
Indoor temperature (*F) 70 7 5
Design temperature difference(OF) 38 18
T-0
fiMAq6LqRMRM&� - .
Area Btuh % of load
Wall 2557 9.8
Floor 10541 40.6
Ceiling 2256 8.7
Windows 3040 11.7
Infiltration 5225 20.1
System Efficiency Loss 2362 9.1
Total: 25980
Head ng Loads
25 980 BTIJ/hr
Ceiling
System Efficiency-ass:
Floor Wall
Wind..�
Infilb-abon
Area Btuh % of load
Wall 1211 4.7
Ceiling 1068 4.1
Windows 13966 53.9
Sensible Infiltration 1856 7.2
Latent Infiltration 3379 13
System Efficiency Gain 2148 8.3
Internal 1257 4.8
Sensible People Load 515 2
Latent People Load 515 2
Total: 25915
Sensible load 22021
Latent load 3894
SHIR 0.85
Capacity at .75 SHIR 2.45 Tons
Cool i ng Loads
25,915 B�/hr
S;71DIle People Load
Latent Poodle Load
Cdiling
—W.I I.I td,n.1
7 IM�Sonsible Infiltratig
Windo.�
tent Infiltrabon
WhIl"ZO 11116Z&%�=112M A UZIVI—N KAM IrA
AED Graph
30000
20000
10000
0
Sam 9�io 10am 11am 12pm 1p� 2pm 3pm 4pra 5p� firm 7pm 8pm
Houdy boads —A
;ACCA Manual S
System equipment selec bon will be madeusing thefollowing Manual Sdenvedyalues.
Summer Outdoor 930F
Summer Wet Bulb 770F
Summer Indoor 75'F
Summer Design Grains 50%
Winter Outdoor 320F
Winter Indoor 70OF
Sensible Cooling 22,021 Btuh
Latent Cooling 3,894 Btuh
Required Cooling Airflow 1,001 CFM
Sensible Heating 25,980 Btuh
Required Heaing Airflow 337 CFM
All calculations are based upon approved hvac ndusp), standards and Drocedures,and comply wito all local,
state and federal code requirements All computed results are Estmate;.Product provided by Energy Design
Systems and Idea Tree
AsKIN03CERTIFIEDO.
vi a trig ire ct a,a rg
L
Certificate of Product Ratings
AHRI Certified Reference Number: 3874552 Da e: 8/3/2012
Product: Split System: Heat Pump with Remote Outdoor Un t-Air-Source
Outdoor Unit Model Number: 25HBB33OC31
Indoor Unit Model Number: FB4CNF030
Manufacturer: CARRIER AIR CONDITIONING
Trade/Brand name: BASE 13 PURON HP
Manufacturer responsible for the rating of this system count!nation is CARRIER AIR CONDITIONING
Rated as follows in accordance with AHRI Standard 210/240 2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating a xuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity (Btuh): 30000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13,00
Heating Capacity(Btuh)@ 47 F: 30000
Region IV HSPF Rating(Heating): 8.00
Heating Capacity(Btuh)@ 17 F: 19400
Ratings followed by an anstals,I-)indicate a voluntary rehar,Of p—...gy cOuliblad lots ai a Rshavi with a NAS which chicane,an in-l—la,aga.
DISCLAIMER
MRI does mail andoes"Me proalucts)Rated on able Cerighicarm and shmakes a.represented.,s,—.at........andes.a.so,and a...my respeani for,
Me drial law on MW Certificate.AFRI..,..at,fterl.k..11 liability my of.......f try kind an,..,out of Me use or derfingranance of Me products),or Me
Musaftenceraged�n of deme Rated on Mis Cerafficals.Certified ratings am valid only for in Asia and confeurations IdMkd in Me directory a wwrivalbruchroncyck,har,
TERMS AND CONDITIONS
Th's Certificates and se�m�am Products 0 AHRI,This Certilksade&i only of used for Individual,Thai and confiderstal reference purgardem.
no contands oi Cartel many in,In aluble or In dead.Im mdroduchyd;cosed;Masai sided;entered into a computer dedusbasse;or otherverse I.W,,n
burns an maker or by any real except for Me users individual,fiessional and confidential afference.
CERTIFICATE VERIFICATION
no Internal horthe nabbehal cases on MW faradic can bar yeaffed 9 wriviv,althindinfroar,of 9, AS "IMF A Conditioning,Heating,
,ad fy C"'cam,ad,and entarthe ARM Cerfiffell Reference flundarrand Me doe can ru an lid ."d Refrigeration Institute
".h Me wass should,asi.Rated!alsove,and Me Certificate No.,which is listed bedraw.
@ 2012 A ir-Condition I ng,Heart ng,a nd Rein geration I in stit ute CERTIFICATE NO.: 12988,S26445603237
ch",