Loading...
60 Beach Cottage Ln HVAC 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-CO001024 Date 8/07/12 Property Address . . . . . . 60 EEACH COTTAGE LN Application type description MECEANICAL HVAC ONLY Property zoning . . . . . . . TO EE UPDATED Application valuation . . . . 0 ---------------------------------------- ------------------------------------ Application desc 1 cu 1 ahu ---------------------------------------- ------------------------------------ Owner Contractor ------------------------ ------------------------ SOUTHERLAND NANCY T TROPIC AIRE OF NORTH FLORIDA 60 BEACH COTTAGE LANE 9969 OLD KINGS ROAD ATLANTIC BEACH FL 322331985 JACKSONVILLE FL 32219 (904) 719-9600 ---------------------------------------- ------------------------------------ Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/03/13 ----------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ----------------------------------------------------------------------------- Fee summary Charged laid Credited Due ----------------- ---------- ----------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 I PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF TLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMITAPPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic fleach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: t.00 PERMIT# PROJECT VALUE $ ARI # REQUIRED NEW AIR CONDITIONING & HEATING SYSTEIN t INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per U it Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity k Tons Per Unit Heat: Unit Quantity BTU's Per U riit Seer Rating Is Duct Systems: Total CFM R E Q FI_R-ED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat .�_'xchanger Quantity of Outlets Purnr s Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tank., (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is ;uspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and o-dinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state oi local law regulation construction or the performance of construction. N Nlmtj _��&'L t Property Owners Name Gt�� Phone Number Mechanical Company_ T-�Zo�otc_ AvAle-&- —Office Phone-1 1.3`1(oW Fax '-I (�5-455Z/ Co. Address: q q 6"1 L) City J" State R. Zip-322t? License Holder(Print). State Certification/Registration#C-&C 0 5-7 3 Notarized Signature of License Ho r om and u ribe e orehy6his day;o je/:Ll,U, 20 IZ_ SHIRLEY L.GRAHAM My COMMISSION#DO 957760 UPIRES:February 14,2014 S natureofNotar Pub�lic_�__ A bonded Thro Notary Public Underwriters DesignStar Load Calculation im Results are intended for use with Rhe-m heating and cooling systems only Tne Nc.* 'Dowoc, o' �Customer Information ............I................................... .......... ................. ................. Location: -.....-- Street Address 60 beach cottage, DUVAL, FL 32233 ............--.....................- - ................................................. .......................................... ........................... .................................................... .......... Latitude, Longitude 30.33750, -81.76860 I............ ........................................I I--.....................................--................1-1............- ........---......................-.......................................................- ................. .................. House Square Footage: 950 sq. ft. ............................................. .................................I.............. .................. ............. .................................. .................................. Name: NANCY SOUTHERLAND ................... ..........................--............... .................. .......... ............... ................................................................. Phone: ..........I................I-- I ............................ ................................................... ............................. ...............I............. ....................-.................................. Email: .............I...................1-.............. ........................................................................................ ............ ........................................................................................................... ................................. Design Conditions Outdoor Hi ating Cooling ................. ............................................... ............. .................. ........................................... Dry bulb (OF) 32 93 -.....................................................................................I.......... .............................................................................................................I.............................. ....................... Daily range I M ...................I.............................................. .......... ............ .........................................................................................................................................- ...................... .................. Relative humidity 1 50% ...........I...............................................................................-.1 1....................... .............. .................... .......... .................... ................................................................................................................... Moisture difference 53 .................................................................................................. ........... ................................. .................. .................................................... Indoor Heating Cooling ........................................................................................................................................................... ................ ................................................................................................................ Indoor temperature (OF) 70 75 ......................I..................................- ---................................................................................................................................................................................................................................................................I............ .......... Design temperature difference(OF) 38 18 ......................................................................I.......... ...................................................... ........................... .............................................................................................. M=CAwZA Area Btuh % of load .......................................... ................................... .........L L........................... Wall 2355 8.6 .........................L............. ............................... ...........................- ...................................... Floor 13650 49.7 ..........................I..............................111.1..............................................I.............L............... ....... Ceiling 1913 7 ..........I........................ ............................................. ­­............L.......... .......................... Windows 2603 9.5 ........................................ ...............--....................-................ Infiltration 4432 16.1 ...............1-1.1 .... -...............................I........................ ................. .......................... System Efficiency Loss 2495 9.1 11-.........................................I.............................................I I I I...............I............1-1 .............11, 1.................................... T.o t.a..I:............................ ...............................................--2 L'7"4"4"8........... ................................. .................. -............ Heating Loads 27,448 BTU/hr Ceiling Wall System Efficiency Floor FAk-I Windows Infiltration Area Btuh % of load ...................................................................................... .................- ............................................... Wall 1115 5 -...............-..................... ............................................-.....................................................................- Ceiling 906 4.1 ..............I..................................................................................... ................................................. .................... Windows 11958 53.9 ........................I .......................................... ..............I...........I.................... .............. Sensible Infiltration 1574 7.1 I.......... ..............I................................................-'--.............--...........---................... Latent Infiltration 2866 12.9 ........................................................................... ............................................................................................. System Efficiency Gain 1842 8.3 .................................. ..................................- ...............................................................--.-............................... Internal 1066 4.8 .............11.1 - I .. 1-1. -.............I.................. ..................................................-.1 ............ .......... Sensible People Load 437 2 ............................................................................................................---- -- - ...................................................... Latent People Load 437 2 -.1-1.1-1...................................................................................................................--............................. ............... .................. T o ta 1 2 2 2 0 2 ..................... Sensible load 18899 ............................................................................. ................................... Latent load 3303 ............................................................ ............................................................... ............. SHR 0.85 .............................................................................................................................................................................. Capacity at .75 SHR 2.10 Tons ............................................. .......................-.................. ......................-..........................I............ ............ ----------- Cooling Loads 22,202 BTU/hr Sensible People Load Latent People Load r—f,--Ceiling Internal Wall Sensible Infiltrati( Windows System Efficienc� tent Infiltration E-19 1010,9=10M=a MAWA-,M=--A MIALWA WMA AED Gr aph 20000 15000 10000 5000 0 Sam 9am 10am 11am 12pm 1pm 2pm 3pm 4pm 5prn 6pm 7pm 8pm Hourly Loads —Av�rage ACCA Manual S System equipment selection will be made using the following Manual S(erived values. Summer Outdoor 930F ....................... -.......... ............... ..........11............... ................. ................11 1 1 ....................................... Summer Wet Bulb 770F ............................................................ ............................... ...................I.................. ........... ........................................... Summer Indoor 750F I............................................................................................................. ................................... ................ ..............--................--............ ..........................-.................................................. Summer Design Grains 50% .............................."................................1 -.1 1 1--.............. ............... ....................... ..................................... ...................-................................................................................................................................................ Winter Outdoor 320F 1.1..........- I-...............I I.................... ............................... ...................... ............ .........................-.1........I........... Winter Indoor 70OF .......... .......... ........... ..........1 11 11 -................................................................... Sensible Cooling 18,899 Btuh .................................. ........... ............- ........................................... Latent Cool i ng 3,303 Btuh .......................................................................................................................................................................................................... ........................... -...........I- I.............. ........... ............................ Required Cooling Airflow 859 CFIVI ............ ..........I.., I I......................................................... Sensible Heating 27,448 Btuh I.............................................I.............................................................................................................................................................................................................................................................................................................................. Required Heaing Airflow 356 CFIVI ............I I................- - I................... ...................- ...........-..........--..........-............................ --.......... .................................. .................... All calculations are based upon approved hvac industry standards and )rocedures,and comply with all local, state and federal code requirements,All computed results are Estimate;.Product provided by Energy Design Systems and Idea Tree 0% "Imp A11111MUNILI CERTIFIEDTM L www.ahridi L recto ry.org —_____-A Certificate of Produci Ratings AHRI Certified Reference Number: 3405689 Dime: 8/7/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBB324C31 Indoor Unit Model Number: FV4CNFOO2 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: BASE 13 PURON HP Manufacturer responsible for the rating of this system coml:!nation is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating a.-curacy by AHRI-sponsored, independent,third party testing: Cooling Capacity (13tuh): 23600 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 24000 Region IV HSPF Rating (Heating): 8.60 Heating Capacity(Btuh)@ 17 F: 14400 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless alcornpanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representation s,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of iny kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for m 3,dels and configurations listed in the directory at www.aliridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;dissernh lated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential'eference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.oi g, A "Imp, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. JIMU 00 ILI and Refrigeration Institute @2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 129888250812183328