374 8th St HVAC 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001043 Date 8/13/12
Property Address . . . . . . 374 8TH ST
Application type description MEC ANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
--------------------------------------- ------------------------------------
Application desc
1 cu 1 ahu
--------------------------------------- ------------------------------------
Owner Contractor
------------------------ ------------------------
374 8TH STREET LLC DONOVAN HEATING & AIR
1750 BEACH AVENUE 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JAX BEACH FL 32250
(904) 241-3785
--------------------------------------- ------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 87 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 2/09/13
--------------------------------------- ------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STA-E MECH DBPR SURCHARGE 2 . 00
--------------------------------------- ------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- --- ------ ---------- ----------
Permit Fee Total 87 . 00 87 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 91 . 00 91 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.I
MECHANICAL 7an APPLICATION
CITY OFAC BEACH
800 Seminole Rd ach,FL 32233
Ph(904)247-58 )247-5845
JOB ADIDRM: S (�
�#
PROJECT VALUES 3 BUD. UV
NEW AIR CONDITIONING&HEATING SYSTE W INSTALLATION
Air Conditioning Unit Quantity Tons Per.0 at
Heat: Unit Quantity_. BTU's Per nit
Duct Systems: Total CFM - — Seer -
REQUIRED
REPLACEMENT AIR CONDITIONING&HEA G SYSTEM INSTAT�,T•A
Au Co�o�g unit Y I Tons Per U _ �.5 ARI# 3'11
1 Unit �— BTU's Per
Duct Systems: Total CFM °o Seel'Rating_ 1`1.5
REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity
(Requires 3 sets of plans)
Fire SFur Main (Requires 3 sets of plans)
Fite Hoa Cabinets Value p�
(Requires 3 sets of
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
(Requires 3 sets of plans)
FIRE PLACES MIS LANEOUS:
Pref"Gas Piping cared Fire�Qty A obile Lifts
BTU's
ALL OTHER GAS PIPING Ele rs/Escalators
Quantity of Outlets Pimps changer
#Vented Wall Furnaces Re;&ig Condenser BTU's
#Water Heaters Solar C bliection Systems
Tanks 1 gallons)
Wells
OTSE;R-
Permit becomes void if work does not txaoe within a six month period or wojisor abandoned forsix months I hthis applicathon and ltaow the same bo betree and Wrteck All provisions of laws �, work will ettiby 'that I have read
x not. Thepem*does not give authority to violate the visions of any other stlaw died with whether
mon eonsftuWon or the specified
?mperiy Owners Name l�oa�-) -tn►C� ,r Phone Number Jconstruction.
qg
Aechanical Company I�ovl n + -3- h4h a Office Phone 'Z`t(3?KS Fax 'Z.H 1-3-)9s
�o.Address: 31 S (.per �>rt- S,
City 1) c c k State fL Zip 3 aaSy
license Holder(Print): ►� i-i!✓� V �CatiOD/R on# 4
ttotarizegiS' ure ofLicewe.Solder
Sworn subscribed before me -_.[1l___day of v vJ
20�
Signatiue of Notary Public '
yik
tate of FbridaHughesn EE 1082782018
wrightsoft- Project Summary IDate: August 9,2012
Enure House By: Aaron Thacker
Donovan Heat& Air
315 6th Ave S,Jacksonville Beach,FL 32250 Phone:904-241-3785 Fax 904-241-3745 Eni ail:aaron@donovanac.com Web:www.DonovanAC.com
Project • •
For: Charles Perniciaro
374 8th St, #6,Atlantic Beach, Fl.32266
Notes:
Design InforrTiation
Weather: Jacksonville M yport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF OU side db 99 OF
Inside db 70 OF Inside db 75 OF
Design TD 31 OF Dign TD 24 OF
Day range L
Re tive humidity 50 %
Mo ture difference 69 gr/lb
Heating Summary Se isible Cooling Equipment Load Sizing
Structure 10302 Btuh Stricture 12830 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Cei itral vent (0 cfm) 0 Btuh
Humidification 0 Btuh Bic Ner 0 Btuh
Piping 0 Btuh
Equipment load 10302 Btuh Us manufacturer's data n
Rai atswing multiplier 1.04
Infiltration Eqt ipment sensible load 13344 Btuh
Method Simplified Ltent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 StrIts
cture 1327 Btuh
Du 0 Btuh
Heating Cooling Cetral vent (0 cfm) 0 Btuh
Volume ft'(ft3) 01 5309 Eqpment latent load 1327 Btuh
Air changes/hour 0.61 0.32 Eq ipment total load 14670 Btuh
Equiv.AVF(cfm) 54 28 R . total capacity at 0.75 SHR 1.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Mae Tempstar
Trade 13 SEER N SERIES R410A HP Tr 13 SEER N SERIES R410A HP
Model N4H318CKA* Cal d N4H318CKA*
AHRI ref no3713763 Coi FEM4P18**A*++TXV
AH ZI ref no3713763
Efficiency 7.8 HSPF Effi iency 12.2 EER, 14.5 SEER
Heating input Ser sible cooling 13500 Btuh
Heating output 18000 Btuh @ 47*F Latent cooling 4500 Btuh
Temperature rise 27 OF Tot I cooling 18000 Btuh
Actual air flow 600 cfm Act jal air flow 600 cfm
Air flow factor 0.058 cfm/Btuh Air low factor 0.047 cfm/Btuh
Static pressure 0 in H2O Sta is pressure 0 in H2O
Space thermostat Loa J sensible heat ratio 0.91
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft" 2012-Aug-0912:13:47
!!��,� � g Right-Suite®Universal 8.0.24 RSU05995 Page 1
AM C:\Users\OwnerlDocuments\Wrightsoft HVAC\Bogus 1.5 ton.rup Calc=MJ8 Fr t Door faces: N