Loading...
126 Fleet Landing Blvd 2012 HVAC . ,I V 1 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 II Application Number . . . . . 12-60001058 Date 8/14/12 Property Address . . . . . . 126�FLEET LANDING BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 3500 --------------------------------------a------------------------------------- Application desc CHANGE OUT 3 TON SYSTEM --------------------------------------- ------------------------------------ Owner Contractor ------------------------ ------------------------ NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC RETIREMENT FOUNDATION, INC 6491 POWERS AVENUE 1 FLEET LANDING BLVD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 322334599 (904) 724-7211 --------------------------------------- ------------------------------------ Permit . . . . . . MECHANICAL HV 1 NC PERMIT Additional desc . . CHANGE OUT 3 CON SYSTEM Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/10/13 ----------------------------------- ------------------------------------- Other Fees . . . . . . . ST E MECH DCA SURCHARGE 2 . 00 ST E MECH DBPR SURCHARGE 2 . 00 ----------------- -------- ---------- Fee Summary Charged g -- ---Paid--- Credited ----Due--- ------ - - --- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 14, C C PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF I ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. Il MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Bjpach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 JOB ADDRESS: 1 f I c,� �eqeir ,f�6 ,� PERMIT# (Z'X07 A PROJECT VALUE $ 315-00 ARIA,# J�3S82�� REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1- Tons Per Unit 3 Heat: Unit Quantity 2 BTU's Per U it 3-5-00C, Seer Rating 1'3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity �I', (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boiler' BTU's Elevat' rs/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets PUMP #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is s:`'spended or abandoned for six months.I hereby certifythat I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or I ocal law regulation construction or the performance of construction. Property Owners Name Phone Number OZ(-16-9900 Mechanical Company kk9-ja Office Phone )-11 Fax Co. Address: rO w err j' �Q n�P — City )LC,k3ot1,j` 11'e State Zip 321 License Holde&( jMilf,z�� Sta Certification/Registration# CA-C65-71Fo NNN 7- Notarized rhe apse Holder MY Comm.Expkes Sworn and subscribed before e this f 3 day of S 20 12 January t0,2o14 • No.DD 950873 tn• Signature of Notary Public Lk OF�ti►r-t`O,`````� . . wrightsoft Right J®Mobile Report Date: 8/1312012 Entire House By: David Gray Heating and Air, INC. k 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabin ky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit# 126,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design C• • P, • ns Location: Incoor: Heating Cooling Jacksonville/Craig, FL, US ndoor temperature (°F) 70 75 Elevation: 43 ft )esign TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Ooisture difference(gr/Ib) 8.4 52.8 Dry bulb(T) 35 91 Inf Itration: Dailyrange (°F) - 17 ( M Oethod Simplified V\kt bulb(°F) - 77 construction quality Average Wind speed (mph) 15.0 7.5 --ireplaces 0 Heating Component Btuh/ftz Btuh %of load Walls 8.3 12641 41.2 IrMbAcn Glazing 19.7 3320 10.8 Doors 13.5 433 1.4 Ceilings 1.7 2438 8.0 VAI Floors 6.2 8963 29.2 Ams Infiltration 2.1 2869 9.4 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 aaarg �Callrgs Adjustments 0 Total 1 30663 100.0 R Component BtuMI2 Btuh %of load �! Walls 4.1 6169 26.9 Glazing 48.2 8113 35.4 Irterel Gins Doors 11.4 367 1.6 IV1d Ceilings 2.6 3720 16.2 h' IrfiltrEtim Floors 0 0 0 k Infiltration 0.5 691 3.0 Ducts 0 0 Ventilation 0 0 Celings Internal gains 3860 16.8 Blower 0 0 CthEr Adjustments 0aaang Total1 1 22920 100.0 Latent Cooling Load= 1784 Btuh Overall U-value=0.147 Btuh/fta--°F Data entries checked. I wi.� hfts ft' - 2012-Aug-13 08Page Right-Suite®Universal 2012 12.0.11 Right J®Mobile Page 1 AM C:\WINDOWS\TEMP\wstmp\895elde0-bd21-4ee0-853b-5edfc9ce26aa.rup Calc-MJ8 Hcluse Front faces: N 4. . . wrgttft° Project Summary Date: 8/13/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904724-5925 Email rzabinl ky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit# 126,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-249-9455 Notes: Design Information Weather: Jacksonville/Crag, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Out side db 91 °F Inside db 70 of Insie db 75 of Design TD 35 F De Ign TD 16 F Dai y range M Relative humidity 50 % Moi r ture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 30663 Btuh Str 'cture 22920 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Cer tral vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30663 Btuh Use manufacturer's data y Rat /swing multiplier 1.00 Infiltration Eq ipment sensible load 22920 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Str cture 1784 Btuh Du s 0 Btuh Heating Cooling Ce 'tral vent(0 cfm) 0 Btuh Area(ftp 1438 1438 Eq ipment latent load 1784 Btuh Volume(ftp 10066 10066 Air changes/hour 0.45 0.23 EqIipment total load 24704 Btuh Equiv.AVF (cfm) 75 39 Re . total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mai a Goodman Trade Trade Model ARUF36C Cord GSZ13 AHRI ref Coil'. AH I ref Efficiency 0 AFUE Effi iency 13 SEER Heating input 0 MBtuh Se ible cooling 0 Btuh Heating output 0 Btuh Lat nt cooling 0 Btuh Temperature rise 0 °F Tot I cooling 0 Btuh Actual air flow 1043 cfm Act al air flow 1043 cfm Air flow factor 0.034 cfm/Btuh Air ow factor 0.046 cfm/Btuh Static pressure 0 in H2O Sta"c pressure 0 in H2O Space thermostat Loa sensible heat ratio 0.93 Calculations approved by ACCA to meet allrequirements of Manual J 8th Ed. , � I 2012-Aug-1308:55:02 .� h Right-Suite®Universal 2012 12.0.11 Right J®Mobile r Page 1 C:\WINDOWS\TEMP\wstmp\895elde0-bd21-4ee0-853b-5edfc9ce26aa.rup Calc=MJ8 +e Front faces: N +~ Job: wlnightsofIr Right-J® Worksheet Entire House Date: 8/13/2012 By: David Gray Heating and Air, INC. I' 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904724-7211 Fax:904-724-5925 Email:rzabini:sky@davidgrayonline.com Web:www.davidgrayonline.com Licens... 1 Room name Entire House First Floor 2 Exposed wall j 190.8 ft 190.8 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 1438.0 ft 5 Room area 1438.0 ft' 1438.0 ft' Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') I Load °F) number (Btuh/ft'- (Btuh/f t2) or perimeter ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/ Heat Cool Gross N/P/S Heat Cool 6 15A-2s3oc-2 0.269 ne 8.35 4.09 252 227 1896 929 252 227 1896 929 i D-c2ow, 0.570 ne 19.72 46.75 25 0 493 1169 25 0 493 1169' t 15A-2s3oc-2 0.269 se 8.35 4.09 612 551 4603 2256 612 551 4603 2256 0 1 D-c2ow 0.570 se 19.72 49.18 61 0 1200 2992 61 0 1200 2992 11 15A-2s3oc-2I 0.269 sw 8.35 4.10 234 212 1767 867 234 212 1767 867 L__G 1 D-c2ow 0.570 sw 19.72 49.18 22 0 444 1107 22 0 444 1107 15A-2s3oc-2 0.269 w 8.35 4.09 25 23 192 94 25 23 192 94 t-G 1 D-c2ow 0.570 w 19.72 63.01 3 0 49 158 3 0 49 158 15A-293oc-2> 0.269 nw 8.29 4.01 594 5(4 4183 2024 594 504 4183 2024 1D=c2ow 0.570 nw, 19.72 46.75 57 0 1134 2688 57 0 1134 2688` 11 D0 0.390 nw 13.49 11.43 32 32 433 367 32 32 433 367' C 16B-19ad 0.049 1.70 2.59 1438 438 2438 3720 1438 1438 2438 3720 F 22A-cph 1.358 46.99 0.00 1438191 8963 0 1438 191 8963 0 I 61 c)AED excursion 101 1 1 10 Envelope loss/gain 1 27794 18369 1 1 27794 18369 12 a) Infiltration 2869 691 2869 691 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 2 460 2 460 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 30663 22920 30663 22920 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1 30663 22920 30663 22920 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 1 1 Aotal mqui dload(dm) 1 1 1 3100431 210431 1 1 31026631 043 10431 Calculations a roved by ACCA to meet all r6auirements of Manual J 8th Ed. wrights-otV Right-Suite®Universal 2012 12.0.11 Right J®Mobile 2012-Aug-1308:55:02 Page 1 C:\WINDOWS\TEMP\wstmp\895elde0-bd21-4ee0-853b-5edfc9ce26aa.rup Calc=MJ8 H Fuse Front faces: N Component Constructions Job: wrights� Date: 8/13/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabin:;ky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit# 126,,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-94 55 Design Conditions Location: Int oor: Heating Cooling Jacksonville/Craig, FL, US indoor temperature (°F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Vloisture difference(gr/lb) 8.4 52.8 Dry bulb(°F) 35 91 Inf ltration: Dailyrange (°F) - 17 ( M Vlethod Simplified Wet bulb(°F) - 77 3onstruction quality Average Wind speed (mph) 15.0 7.5 :ireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain ft. Btuh/ft'-"F ft'-°F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh Walls 15A-2s3oc-2:Bg wall,heavy dry or light damp soil,empty core, ne 227 1 0.157 2.0 8.35 1896 4.09 929 concrete block wall,r-2 ins, 10"thk se 551 0.157 2.0 8.35 4603 4.09 2256 sw 212, 0.157 2.0 8.35 1767 4.10 867 w 23 0.157 2.0 8.35 192 4.09 94 nw 504 0.157 2.0 8.29 4183 4.01 2024 all 1517! 0.157 2.0 8.33 12641 4.07 6169 Partitions (none) Windows 1 D-c2ow:2 glazing,clr outr,air gas,wd firm mat,clr innr,1/4"gap, ne 25 0.570 0 19.7 493 46.8 1169 1/8"thk se 61 0.570 0 19.7 1200 49.2 2992 sw 23 0.570 0 19.7 444 49.2 1107 w 3! 0.570 0 19.7 49 63.0 158 nw 58 0.570 0 19.7 1134 46.8 2688 all 168 0.570 0 19.7 3320 48.2 8113 Doors 11 D0:Door,wd sc type nw 32'', 0.390 0 13.5 433 11.4 367 Ceilings 16B-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins, 1/2" 1438 0.049 19.0 1.70 2438 2.59 3720 gypsum board int fnsh 4 ly Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 191 li, 1.358 0 47.0 8963 0 0 i' 2012-Aug-13 08:55:02 WrI9ht!1110 Right-Suite®Universal 2012 12.0.11 Right JO Mobile I!, Page 1 C:\WINDOWS\TEMP\wstmp\895elde0-bd21-4ee0-853b-5edfc9ce26aa.rup Calc=MJ8 Huse Front faces: N i wrghsoftAED Assessment Dae: 8/13/2012 Entire House By: David Gray Heating and Air, INC. 4 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904724-7211 Fax:904-724-5925 Email:rzabinlky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#126,'Atlantic Beach, FL 32233 Phone:904-246-9900 Fax: 904-246-9455 Design Conditions Location: Incoor: Heating Cooling Jacksonville/Craig, FL, US ndoor temperature (°F) 70 75 Elevation: 43 ft )esign TD (°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling oisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Wet bu Ib(T) - 77 Wind speed (mph) 15.0 7.5 Test for • - • Exposure Hourly Glazing Load 10,00(k 9,00 8,00 7,00 4 6,00 5,00 4,00 3,00 2,00 1,00 08 9 10 11 12 13 14 "' 15 16 17 18 19 20 Hour of Day Homy Aer-age PEDlimit Maximum hourly glazing load exceeds average by 1 .3%. r House has adequate exposure diversity (AED), bas d on AED limit of 30%. AED excursion: 0 Btuh l 4 i �' 2012-Aug-1308:55:02 '`'�� WirtWt Right-Suite®Universal 2012 12.0.11 Right JO Mobile Page 1 A"✓L.+�++ C:\WINDOWS\TEMP\wstmp\895elde0-bd21-4ee0-853b-5edfc9ce26aa.rup Calc=MJ8 Huse Front faces: N