Loading...
5420 Fleet landing Blvd 2012 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001071 Date 8/16/12 Property Address . . . . . . 1 FLEET LANDING BLVD MAIN Tenant nbr, name . . . . . . UNIT 5420 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC FLEET LANDING 6491 POWERS AVENUE 1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 32233 (904) 724-7211 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/12/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 4100, 800 Seminole Rd Atlantic Beach, FL 32233 ILM Ph(904) 247-5826 Fax(904) 247-5845 J OB AD D RE S S: ti)11 ,,,C, �c t,41 tevr,V) P E RMrr# PROJECTVALUE $ '7, 5-00 ARI# F, REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3 Heat: Unit Quantity BTU's Per Unit Seer RatinR i Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the ovisions of any other state or local law regulation construction or the performance of construction. P3 Phone Number 99 C Property Ovvrners Name ee Mechanical Company (�y N�--, yeld-� ir 1-r�c Office Phone ;72'Y ;ZD 4 Fax—��Z�5�2-J;- Co. Address: W e f 5' A'V e t-1(A city T&Oq , State zip ;a2l it le OC) License j0!:Fej1qV;71 State Certification/Registration# _4q-C 057:7/C *6T Nota I *katu nse Holder mycomm. jwLmry 10,2014 Sworn and subscribed before this da of 4&6(Aj-� C, -'4 Signature of Notary Public -Q. -1. No.DD V50913 V 0 Right J@ Mobile Report Job: wrightsoft Date: 8/16/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens Proiect Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5420,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(*F) 70 75 Elevation: 43 ft Design TD(oF) 35 16 Latitude: 30'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(*F) 35 91 Infiltration: Dailyrange(*F) - 17 ( M Method Simplified Wet bulb(*F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btu h/ft' Btuh %of load Walls 8.3 12641 41.2 Irthrabon Glazing 19.7 3320 10.8 Doors 13.5 433 1.4 Ceilings 1.7 2438 8.0 N 11 Floors 6.2 8963 29.2 Rms Infiltration 2.1 2869 9.4 Ducts 0 0 Piping 0 0 Al Humidification 0 0 ---1 Ceiflir-gs Ventilation 0 0 Gadrig Clu Adjustments 0 Total 30663 100.0 Component Btu h/ft2 Btuh %of load Walls 4.1 6169 26.9 Glazing 48.2 8113 35.4 Interrd Gins Doors 11.4 367 1.6 WAI Ceilings 2.6 3720 16.2 Infiltrafiart Floors 0 0 0 1 Infiltration 0.5 691 3.0 Ducts 0 0 Ventilation 0 0 Cailirgs Internal gains 3860 16.8 Blower 0 0 ahEr Adjustments 0 Ga2ing Ct Total 22920, 100.01 Latent Cooling Load 1784 Btuh Overall U-value=0.147 Btuh/ft2-*F Data entries checked. + wright"ft' Right-Suitee Universal 2012 12.0.12 Right JO Wbile 2012-Aug-16 06:32:32 C:\WINDOWS\TEMP\wstmp\39c36552-fO95-4418-gf5c-ld5778c43d79.rup Calc=MJ8 House Front faces: N Page I Project Summary Job: wrightsoft Date: 8116/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens Project Information For: Fleet Landing I Fleet Landing Boulevard-Unit#5420,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Notes: Design Information Mi Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 *F Inside db 70 *F Inside db 75 *F Design TD 35 oF Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 30663 Btuh Structure 22920 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30663 Btuh Use manufactu'rer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22920 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1784 Btuh Ducts 0 Btuh Area(ft2) Heating Cooling Central vent(0 cfm) 0 Btuh 1438 1438 Equipment latent load 1784 Btuh Volume(fl?) 10066 10066 Air changes/hour 0.45 0.23 Equipment total load 24704 Btuh Equiv.AVF(cfm) 75 39 Req.total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Trade Model ARUF36C Cond GSZ13036 AHRI ref Coil AHRI ref Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btu h Latent cooling 0 Btuh Temperature rise 0 *F Total cooling 0 Btuh Actual air flow 1043 cfm Actual air flow 1043 cfm Air flow factor 0.034 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.93 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlightSOft Right-suitee Universal 2012 12.0.12 Right JS Wbile 2012-Aug-1 6 D6:32:32 C:\\MNDOWS\TEMP\wstmp\3gc36552-fO95-4418-gf5c-ld5778o43d79.rup Calc=MJ8 House Front faces: N Page 1 .A. *FP*Wrotsoft. Right-A) Worksheet Job: Entire House Date: 8116/2012 David Gray Heating and Air, INC. By: 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.CDm Licens I Room name Entire House First Floor 2 Exposed wall 190.8 ft 190.8 ft 3 Room height 9.0 ft d 9.0 ft heatt000l 4 Room dimensions 5 Room area 1438.0 ft2 1438.0 ft2 1.0 x 1438.0 ft Ty Construction U-vaue Or HTM.) Area (W) Load Area (ft2) Load number Btuhlft--'F) (Bt uh/ft or perimeter (ft) (8tuh) or perimeter (ft) (Btuh) Heat Cool LGro _:-�: N/P/S Heat Cool G ss N/P/S Heat CooEl 6 %L__G 15A,2s3oo-2 0.269 ne 8'35 4 09 262 227 1896 929 252 227 1896 929 1 I D-c2ow 0.570 ne 19.72 46.75 25 0 493 1169 25 0 493 1169 15X2s3oc-2 0.269 se 8.35 4.09 612 551 4603 2256 612 551 4603 2256 t-G 1D-c2ow 0.570 se 19.72 49.18 61 0 1200 2992 61 0 1200 2992 11 Vt__G 16X2s3oc;,2 0.269 sw 8.35 4.10 234 212 1767 867 234 212 1767 867 1D-c2ow 0.570 sw 19.72 49.18 22 0 444 1107 22 a 444 1107 15A-2s3oc-2 0.269 w 8.35 4.09 25 23 192 94 25 23 192 94 VL-G 1 D-c2ow 0.570 w 19.72 63.01 3 0 49 158 3 0 49 158 5A,2s3oc-2 0,269 nw 8.29 4.01 594 504 4183 2024 594 504 4183 2024 t:t I 0-20W 0.570 nw 19.72 46.75 57 0 1134 2688 57 0 1134 2688 1100 0.390 mv 13.49 11.43 32 32 433 367 32 32 433 367 C 16B-19ad 0.049 1.70 2.59 1438 1438 2438 3720 1438 1438 2438 3720 F 22A-cph 1.358 46.99 0�00 1438 191 8963 0 1438 191 8963 0 1 61 c)AED excursion 1 01 1 1 Envelope loss/gain 277941 183691 1 1 277941 183691 12 a) Infiltration 2869 691 2869 691 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 30663 22920. 30663 22920. Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30663 22920 30663 22920 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total room I ad 306631 229201 306631 229201 Air required o(cfm) 10431 10431 10431 10431 Calculations arwoved by ACCA to meet all reauirements of Manual J 8th Ed. '466k -PI4- wrlights'oft' Right-SuiteO Universal 2012 12.0.12 Right J8 Wbile 2012-Aug-16 06:32:32 C:\VVI NDOWS\TEMP\wstmp\,39c36552-fO95-4418-9f5c-I d5778c43d79.nip Calc=MJ8 House Front faces: N Page I Component Constructions Job: wrightsoft Date: 811612012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:r-zabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... 32#91-M For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5420,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(OF) 70 75 Elevation: 43 ft Design TD(OF) 35 16 Latitude: 30*N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(OF) 35 91 Infiltration: Daily range(OF) - 17 M Method Simplified Wet bulb(OF) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain f12 Btuhtff-*F W-0 F/Stuh MAIM Btuh Eltuh/ffl Btuh Walls 15A-2s3oc-2:Bg wall,heavy dry or light damp soil,empty core, ne 227 0.157 2.0 8.35 1896 4.09 929 concrete block wall,r-2 ins,10"thk se 551 0.157 2.0 8.35 4603 4.09 2256 sw 212 0.157 2.0 8.35 1767 4.10 867 w 23 0.157 2.0 8.35 192 4.09 94 nw 504 0.157 2.0 8.29 4183 4.01 2024 all 1517 0.157 2.0 8.33 12641 4.07 6169 Partitions (none) Windows I D-c2ow:2 glazing,clr outr,air gas,wd firm mat,cir innr,1/4"gap, ne 25 0.570 0 19.7 493 46.8 1169 1/8"thk se 61 0.570 0 19.7 1200 49.2 2992 sw 23 0.570 0 19.7 444 49.2 1107 w 3 0.570 0 19.7 49 63.0 158 nw 58 0.570 0 19.7 1134 46.8 2688 all 168 0.570 0 19.7 3320 48.2 8113 Doors 11 DO:Door,wd sc type nw 32 0.390 0 13.5 433 11.4 367 Ceilings 16B-1 9ad:Attic ceiling,asphalt shingles roof mat,r-1 9 ceil ins, 1/2" 1438 0.049 19.0 1.70 2438 2.59 3720 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 191 1.358 0 47.0 8963 0 0 A;". + wrightsoft, Right-Suite42)Universal 2012 12.0.12 Right JS k1lobile 2012-Aug-16 D6:32:32 AM C:NWINDOWSNTEMP\wstmp\39c36552-fO95-4418-9f50-1 0778o4309.rup Calc=MJ8 House Front faces: N Page I wrightsoft. AED Assessment Job: Date: 811612012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens Project Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5420,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 -M Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(*F) 70 75 Elevation: 43 ft Design TD (T) 35 16 Latitude: 30*N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(T) 35 91 Infiltration: Daily range(*F) - 17 ( M Wet bulb('F) - 77 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 10,00 ' 9,OOE- 8,OOE- 7,00 - 6,00t��� 5,OOE- 4,00(- 3,00(- 2,00(- 1,OOE- 0 i 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day .oe FbLrly / Ae-age AEDlimit Maximum hourly glazing load exceeds average by 18.3%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh A;. + WrlightSOft' Right-Suite@ Universal 2012 12.0.12 Right JS Mobile 2012-Aug-1 6 06:32:32 AM C:\WINDOWS\TEMP\wstmp\39c36552-fO95-4418-9f5c-ld5778c43d79.rup Calc=MJ8 House Front faces: N Page 1 CERTIFIEDTM L www.a h r i d irectory.org Certificate of Product Ratings AHRI Certified Reference Number: 5358272 Date: 8/16/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ130361B* Indoor Unit Model Number:ARUF36C14A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 34800 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 34000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 20800 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accornpanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwvvw.aliridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this cerlJificate can be verified at www.ahridirectory.org, "IMF, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ANOU and Refrigeration Institute @2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129896129045162237