1950 Beach Ave unit 1954 HVAC 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001091 Date 8/22/12
Property Address . . . . . . 195( BEACH AVE
Tenant nbr, name . . . . . . UNIT 1954
Application type description MECIANICAL HVAC ONLY
Property Zoning . . . . . . . TO 1E UPDATED
Application valuation . . . . 0
---------------------------------------- ------------------------------------
Application desc
1 cu 1 ahu
---------------------------------------- ------------------------------------
Owner Contractor
------------------------ ------------------------
CLARK KARIN H DONOVAN HEATING & AIR
1950 BEACH AVE. 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JAX BEACH FL 322SO
(904) 241-3785
---------------------------------------- ------------------------------------
Permit . . . . . . MECHANICAL HVIC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 2/18/13
---------------------------------------- ------------------------------------
Other Fees . . . . . . . . . STAqE MECH DCA SURCHARGE 2 . 00
STA7E MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Faid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF A-LANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
tau sual CERTIFIEDT.
www.ahridirectory.org �J)
Certificate of Produci Ratings
AHRI Certified Reference Number: 3853224 Date: 8/22/2012
Product: Split System: Heat Pump with Remote Outdoor Un t-Air-Source
Outdoor Unit Model Number: 25HCB336A30
Indoor Unit Model Number: FB4CNF036
Manufacturer: CARRIER AIR CONDITIONING
Trade/Brand name: COMFORT 13 PURON HP
Manufacturer responsible for the rating of this system coml:!nation is CARRIER AIR CONDITIONING
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating a:,curacy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 34000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 34000
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh)@ 17 F: 21400
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless ac:ornpanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representationi i,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of i ny kind arising out ofthe use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only a used for individual,personal and confidential reference purposes.
2 a contents of this Certificate may not,in whole or in part,be reproduced;copied;dissemi ted;entered into a computer database;or otherwise utilized,in any
1 nr manner or by any means,except for the user's individual,personal and confidential erence.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.orl 1, A "IMP, Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date )n ou
which the certificate was issued,which is listed above,and the Cerdficate No.,which is listed below. 0 On ILI and Refrigeration Institute
@2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 129901186329861726
MECHANICAL PERM rjr APPLICATION
CITY OF ATLANncBEACII
900 Seminole Rd Atkatic&sch,FL 32233
Ph(904)247-5826 Fax(904)247-5945
JOB ADDRFSS: 01,
PROJECTVALUE 3100� 00
NEW AIR CONDITIONING&HEATING SYSTFj I INSTALLAnoN
Air Conditi i Unit Quanttt3,
OMW.
Heat It&11::�o-� Tons Per.un It
Duct Systems: Toted CFM BTU's Per L nit sea
Ratin&
RR E-Q-�UZ M
REPIACEMENT AIR CONDITIONING&HEAtG SYSTEM I I NSTAUATION
Air Conditi Unit Quantit AW#a05S-pz?,�
oning-, U Tons Per
Heat
y
.t REMM
Duct Systems: Total CFM BTUs Per "t-aLQ-12S� Sm Rating_/-3
FORE PREVENTION REQUMED
Fire Sprinkler System Quantity
Fire Standpipe quan* (Requires 3 sets Pians)
Underground Fire,Main value (Requires 3 seft of p
Fire Hose Cabinets Quantity (Requires 3 seft of PhAINJ
Commercial Hoods Quantity (Requires 3 sets of phm)
Fire Suppression systems Quan* (Requires 3 seft of phm)
(Requires 3 seb of phun)
FiREPLACES MIR UJANEOUS:
PnfiLbricated.Fireplace Qty Autam*ile Lifts
Gas Piping Outlets- Boilen BTUs
Elevatqr&�Swzlators
ALL OTHER GAS PIEPING Heat E,,,changer
Quantity of Outlets
#Vented Wall Furnaces PUMPS
#Water Heaters Reffige MtOr CDnden= Uff S—
Solar C)IIection System
Tanks p1lons)
Wells
OTHER:
rk.
Perrrift b=mw-v—o1d if wort does not coommoe wftbm a six mortt—h period or wo
is or abluldomned ffbr sk—mmh&I hereby certify tha I have read
Us 141plicefica nd know ae$Me to be trw md=TOM AH f1mvisions Of laws=Md
Ir W)t ne permft does wt gin mooft to violft ft pmvision of my o&er sWe or loc a, BMWAiDg tW3 work will be COMPbW W911 Wbothiff 40cified
?roperty Owners Name I Fros7o kw mv*dm cortstrtmdan or the puftmance of cortsftuctiaL
Aechanical Company-j,-bnCvr.A Orr PhoneNumber 96V-�535-�39K
� ,+ _).- pqjo Phone 'Z-ti-3) -37 -)S-
-Address: -zz.0-1 S, 'Ity 0&v ?->,e,4ck _Stftt Zip S.-%.-
AceaseHeMerobrw).- W-,tk�u& a v,% )5b
'rototed S4waftm OfLkewse HoMer4 �8UWCerfificafion&egisftvtion# 64C-031161
SWOM subsixibed before me# –4�e�day of—AW 2oa--
40 PUL Notary Public Statf,&Florida ofNotaryPublic
JP
Timothy Lee Hugnes
My Commission EE 186278
Expires 04103/2016
EN I -
wrightsoft- Project Summary Job:
Date- 812M12
Entire House By: Brandon Zahade
Donovan Heat&Air
315 Sth ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email:brandon@donova riac.com
Project Information
For: Frosio
1954 Beach,Atlantic Beach, FL 3233
Notes:
Design Information
Weather: Jacksonville Me yport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 95 OF
Inside db 68 OF Insi db 75 OF
Design TD 29 OF D . gn TD 20 OF
Da range L
Re ive humidity 50 %
M i turedifference 53 gr/lb
Heating Summary Selsible Cooling Equipment Load Sizing
Structure 17610 Btuh StrL-.ture 17691 Btuh
Ducts 4930 Btuh Duds 7343 Btuh
Central vent (31 cfm) 997 Btuh Cen:ral vent (31 cfm) 688 Btuh
Humidification 0 Btuh Blower 0 Btuh
Pipigg 0 Btuh
Equipment load 23536 Btuh Use manufacturer's data n
RaWswing multiplier 1.00
Infiltration Equ pment sensible load 25722 Btuh
Method Simplified L4+1ftnt Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Averagb) Str ture 2467 Btuh
D s
.ufpn
u s 1610 Btuh
Heafin
172g Coolin Ce ral vent (31 cfm) 1132 Btuh
Area(ft') 1720 Eq ment latent load 5209 Btuh
Volume(fts) 15480 15480
Air changes/hour 0.46 0.20 Equ pment total load 30931 Btuh
Equiv.AVF (cfm) 118 52 Req total capacity at 0.70 SHR 3.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make carrier Mak e carrier
Trade Trac e
Model 25hbc336 Coni 25hbc336
ARI ref no. 3853224 Coil FB4CNF036
ARI ref no. 3853224
Efficiency 7.7 HSPF Effic iency 13 SEER
Heating input S�:nsdble cooling 21918 Btuh
Heating output 31157 Btuh @ 47'F It cooling 9394 Btuh
Temperature rise 27 OF Tata cooling 31312 Btuh
Actual air flow 1044 cfm Actt al air flow 1044 cfm
Air flaw factor 0.046 cfm/Btuh Air f ow factor 0.042 cfm/Btuh
Static pressure 0 in H20 Stat c pressure 0 in H20
Space thermostat Load sensible heat ratio 0.83
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
Right-SuiteS Universal 7.1.01 RSU05996 2012-Aug-20 11:02:54
C:\Users\SalesXDocuments\Wrightsoft HVAC\3 Ton.rup Calc=MJ8 Orientation=N Page 1