1285 Main St HVAC 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
� INSPECTION PHONE LINE 247-5814
F .,
Application Number . . . . . 12- 0001103 Date 8/24/12
Property Address . . . . . . 128 MAIN ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO E UPDATED
Application valuation . . . . 0
--------------------------------------- ------------------------------------
Application desc
1 cu 1 ahu
--------------------------------- ------------------------------------
Owner Contractor
BROWN STEPHEN & BOBBIE TROPIC HEATING & AIR
1285 MAIN ST 750 MAYPORT RD
ATLANTIC BEACH FL 322332625 ATLANTIC BEACH FL 32233
(904) 241-1788
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc
Permit Fee . . . . 95 . 00 Plan Check Fee 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 2/20/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OFA LANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANT C BEACH
800 Seminole Rd Atlantic B ach, FL 32233
Ph(900/4) 247-5826 Fax(90,4) 247-5845
JOB ADDRESS: I� s ��'� sil". PERMIT#
ROJECT VALUE $ 380.0""
NEW AIR CONDITIONING & HEATING SYSTE INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per U it Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI# 1-1611-714,1
Air Conditioning: Unit Quantity Tons Per Unit „Z-5- REQUIRED
Heat: Unit Quantity i BTU's Per U it 5,ew Seer Rating /1/0
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Autottiobile Lifts
Gas Piping Outlets Boiler i BTU's
Eleva rslEscalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pump
# Vented Wall Furnaces Refri rator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells'
OTHER:
Permit becomes void if work does not continence within a six month period or work is s,tspended or abandoned for six months.I hereby certify that t have read
this application and know the same to be true and correct. All provisions of laws and or[inauces governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or ocal law regulation construction or the performance of construction.
Property Owners Name Phone Number
Mechanical Company Office PhonFaxeq/ I)7a
Co. Address:750 rn �` City t'C C .State.-Zip lU.�
License Holder(Print): �-- State Certification/RegistrationQA
Notarized Signature of License Holder
Sworn and su scribed before a this c;3 day of AMW& 20�
KAREN E.PANTFOEDER
NOTARY PUBLIC Signature of Notary Public
STATE OF FLORIDA
• Comm#EE064448
Expires 3/4/2015
a 0,
e
v
>e f
r
s
AHRI Certified Reference Number: 4611714 Datb: 8/24/2012
Product: Split System: Heat Pump with Remote Outdoor Uni Air-Source
Outdoor Unit Model Number: 13HPX-030 230-17
Indoor Unit Model Number:CBX27UH-030-230'+TDR
t
Manufacturer:LENNOX INDUSTRIES, INC.
Trade/Brand name: 13HPX SERIES
Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC.
Rated as follows in accordance with AHRI Standard 2101240 008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating allcuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 30800
- EER Rating(Cooling): 11.50
SEER Rating (Cooling): 14.00
Heating Capacity(Btuh)@ 47 F: 27200
Region IV HSPF Rating(Heating): 8.50
z
Heating Capacity(Btuh)@ 17 F: 17100
K
n 'Ratings fcliawed by an aster k,*) ndicate a voiuntary rerate of previously published tea,unless ampanied with a WAS which indicates an invofuntarj cerate_
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representation'i,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of I iny kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for 0 Wells and configurations listed in the directory at
TERMS AND CONDITIONS
, F This Certificate and its contents are proprietary products of AHRI.This Certificate shall only used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in who*or in part,be reproduced;copied;dissemi ated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential rence.
CERTIFICATE VERIFICATIONi
The information for the model cited on this certificate can be verified at
r stick on ' +'+"link and enter the AHRI Certified Reference Number and the date,on
which the certificate was issued,which is listed above,and the Certificate No.,which is listed, low.
02012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 129902835035068639
..x..
Project Summa Job: McWhirter
Date: 8/2312012
Entire House By:
1 A cwi aq$yam
AL
a # 9
For: McWhirter, Tropic Heating&Air Con 'toning
1285 Main St.,Atlantic Beach, FL 32 33
Phone: 904-241-1788 Fax:904-241 172
Notes: Email:Tropicac@msn.com
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 °F Outs Je db 91 °F
Inside db 70 °F Insid db 75 °F
Design TD 35 °F Desii n TD 16 °F
Dailyrange M
Relall ve humidity 50 %
Moisl ure difference 53 gr/Ib
Heating Summary nsible Cooling Equipment Load Sizing
Structure 22611 Btuh Stru ure 18369 Btuh
Ducts 3333 Btuh Duct, 3643 Btuh
Central vent(0 cfm) 0 Btuh Cent' l vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blow.,r 0 Btuh
Piping 0 Btuh
Equipment load 25944 Btuh Use i ianufacturer's data y
Rate wing multiplier 1.00
Infiltration Equi ment sensible load 22012 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Struc ure 2085 Btuh
DuctE 506 Btuh
Heating Cooling Cent I vent(0 cfm) 0 Btuh
Area(ft2) 1200 1200 Equipment latent load 2591 Btuh
Volume(ft') 10800 10800
Air changes/hour 0.45 0.23 Equi meat total load 24603 Btuh
Equiv.AVF(cfm) 81 41 Req. otal capacity at 0.70 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make
Trade n/a Trad
Model n/a Cond'
AHRI ref n/a Coil
AHRI ref
Efficiency n/a Efficincy 0 SEER
Heating input 0 MBtuh Sensi Die doling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Totalbooling 0 Btuh
Actual air flow 979 cfm Actua airflow 979 cfm
Air flow factor 0.038 cfm/Btuh Air flo N factor 0.044 cfm/Btuh
Static pressure 0 in H2O Static,pressure 0 in H2O
Space thermostat Load'sensible heat ratio 0.89
Calculations approved by ACCA to meet all re uirements of Manual J 8th Ed.
I- wri4g ohItSf# 2012-Aug-23 15:28:40
Right-Surte®Uaiversat 2012 12.0.12 Right,1®Mobile
'. .' C:IWANDOWSITHN
Plwstmpbbde8a05-a4fb-42db-bd3ea1b84ft2c0aa.rup Calc=MJB Frontoorfaces W Pagel
Right J®Mobile Report Job: McWhirter
Date: 8/23/2012
Entire House By:
sa
AL
For: McWhirter, Tropic Heating&Air Conditio iing
1285 Main St., Atlantic Beach, FL 32233'
Phone: 904-241-1788 Fax:904-241-21
Email:Tropicac@msn.com
Location: Ind r: Heating Cooling
Jacksonville/Craig, FL, US in oor temperature(°F) 70 75
Elevation: 43 ft sign TC(°F) 35 16
Latitude: 30°N R lative humidity(%) 30 50
Outdoor: Heating Cooling M isture difference(gr/Ib) 8.4 52.8
Dry bul b(°F) 35 91 Infi ation:
Daily range(°F) - 17 ( M ) M thod Simplified
Wetbulb(°F) - 77 C nstruction quality Average
Wind speed(mph) 15.0 7.5 Fi'eplaces 0
Component Btuh/flz Btuh %of load
Walls 3.4 4520 17.4 WIS Dds
Glazing 30.1 4565 17.6
Doors 13.5 425 1.6 Irfittrm
Ceilings 1.7 2034 7.8 .:
Floors 6.7 7988 30.8 Gaft-..
Infiltration 2.0 3078 11.9
Ducts 3333 12.8
{� 9 0 0
Piping ata
Humidification 0 0 Odirgs i=
Ventilation 0 0
Adjustments 0
Total 1 259441 100.0
� s
Component Btuh/ftZ Btuh %of load
Walls 2.6 3514 16.0 IrterF ��
Glazing 61.6 9347 42.5 V\IWIs
Doors 11.4 360 1.6
Ceilings 2.1 2517 11.4 Dints
Floors 0 0 0
Infiltration 0.5 741 3.4
Ducts 3643 16.5 �Irfiftrian
Ventilation 0 0
Internal gains 1890 8.6 jr
Blower 0 0 Gaarg Ceilirc's
Adjustments 0 Ctl1er
Total 22012 100.0
Latent Cooling Load=2591 Btuh
Overall U-value=0.144 Btuh/fF--°F
Data entries checked.
Ll I
Wr![„ htSAft2012-Aug-2915:28:40
Right-Su Re®Univ ersa1201212.0.12 Right J®Mobile
C:%WlNDOWSATEMPtwsbrptcbde8a0Sa4fb-42db-bd3e-alb64ff2cOaa.rup Calc=MJ8 Front D4 rfaces: W Page 1
Component Constructions Job: McWhirter
A= Date: 8/23/2012
Entire House By:
AL
MNNORRaftnaf
a
For: McWhirter,Tropic Heating&Air Condltio ing
1285 Main St.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-217
Email:Tropicac@msn.com
Location: Ind r: Heating Cooling
Jacksonville/Craig, FL, US In oor temperature(°F) 70 75
Elevation: 43 ft D'sign TD(°F) 35 16
Latitude: 30°N R lative humidity(%) 30 50
Outdoor: Heating Cooling M' 'sture difference(grAb) 8.4 52.8
Dry bull b(°F) 35 91 Infi ation:
Daily range(`F) - 17 ( M ) M'thod Simplified
Watbulb(-F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Replaces 0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
fF BhMF-"F R'-'FA'#ih BhhAF Btuh BhhAF Btuh
Walls
1213-0sw:Fnn wall,vnl ext,r-11 cav ins,112"gypsum board int n 212 0.097 11.0 3.36 711 2.61 553
fnsh,2"x4"wood frm a 445 0.097 11.0 3.36 1494 2.61 1161
S 243 0.097 11.0 3.36 817 2.61 635
W 447 0.097 11.0 3.36 1499 2.61 1165
all 1347 0.097 11.0 3.36 4520 2.61 3514
Partitions
(none)
Windows
1 D-c2om:2 glazing,cir outr,air gas,mtl no brk frm mat,cir innr,1/4" n 27 0.870 0 30.1 803 28.1 749
gap,1/8"thk a 50 0.870 0 30.1 1505 78.4 3922
S 27 0.870 0 30.1 803 33.2 884
W 48 0.870 0 30.1 1455 78.4 3792
all 152 0.870 0 30.1 4565 61.6 9347
Doors
11 D0:Door,wd sc type n 32 0.390 0 13.5 425 11.4 360
Ceilings
16C-1 gal:Attic ceiling,asphalt shingles roof mat,r-19 coil ins,1/2" 1200 0.049 19.0 1.70 2034 2.10 2517
gypsum board int fish
Floors
22A-cph:Bg floor,heavy damp soil,on grade depth,carpet flr fnsh 170 1.358 0 47A 7988 0 0
1 W rights ht2012-Aug-2315:28:40
9 Right-Suite®Universa1201212.0.12 Right J®Mobile
" C:\WINDOWS%TEMP1wstmptcbde8a05-a4fb-42db-bd3e-a1b64fP2cOaa.rup Calc=MJ8 Front I xx faces: W Page 1
Right-M Worksheet Job: McWhirter
Entire House Date: 8/23/2012
�„ z�*#sem. By.
AL
1 Room name En i tire House First Floor
2 Exposed wall 170.0 ft 170.0 ft
3 Room height 9.0 ft d 9.0 ft heaticool
4 Room dimensions 1.0 x 1200.0 ft
5 Room area 1200.0 ft2 1200.0 ft'
TY I Construction U-value Or HTM Area (ft') I Load ( Area (ft') I Load
number (Btuhtftl-°F) I (Btuhtft2 I or perimeter (ft (Btu h) or
perimeter (ft) (Btu h)
Heat Cool Gross N/P1S Heat Cool Gross N/P/S Heat Cool
6 126-0sw 0.097 n 3.36 2.61 270 2,2 711 553 270 212 711 553
1 D-c2om 0.870 n 30.10 28.08 27 0 803 749 27 0 803 749
11D0 0.390 n 13.49 11.43 32 Q 425 380 32 32 425 360
Vy 12B-Osw 0.097 a 3.36 2.61 495 1494 1161 495 445 1494 1161
11 L-G 1D-c2om 0.870 a 30.10 78.45 50 0 1505 3922 50 0 1505 3922
12B-Osw 0.097 s 3.36 2.61 270 2 817 635 270 243 817 635
t--t 10-c2om 0.870 s 30.10 33.16 27 0 803 884 27 0 803 884
1l� 12B-Osw 0.097 w 3.36 2.61 495 4 7 1499 1165 495 447 1499 1165
C 10-c2om 0.870 w 30.10 78.45 48 0 1455 3792 48 0 1455 3792
C 16C-19al 0.049 1.70 2.10 1206 1 2034 2517 1200 1200 2034 2517
F 22A-cph 1.358 46.99 0.00 1200 1 0 79W 0 1200 170 7988 0
61 c)AED excursion 01 1 10
Envelope losstgain 19533 15738 1
1 19533 15738
12 a) Infiltration 3078 741 3078 741
b) Room ventilation 0 0
0 0
13 Internal gains: Occupants @ 230 3 690 3 690
Appliances/other 1200
1200
Subtotal(lines 6 to 13) 22611 18369 22611 18369
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 22611 18369 22611 18369
15 Duct loads 15% 3333 3643 15% 20% 3333 3643
Total room bad 25944 22012 1 1 259441 22012
Air required(cfm) 979 979 9791 979
CalcWlationsapmoved by ACCA to meet all regArements of Manual J 8th Ed.
4+4.- wrightn"ft Right-Suite®Universal 2012 12.0.12 Right J®Mobile 2012-Aug-2315:28:40
" C:%WINDOWSITEMPIwsMV%cbde8aO5-a4fb-42db-bd3ealb64ft2c0aa.rup Cab=MJ8 Front D Por faces: W Page 1
AED Assessment Job: McWhirter
Date: 8/23/2012
Entire House By:
AL
For: McWhirter,Tropic Heating&Air Conditior ng
1285 Main St,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax:904-241-217
Email:Tropicac@msn.com
Location: Indor: Heating Cooling
Jacksonville/Craig, FL, US In oor temperature('F) 70 75
Elevation: 43 ftsign TD(°F) 35 16
Latitude: 30°N R ative humidity(%) 30 50
Outdoor: Heating Cooling Mi 'sture difference(grAb) 8.4 52.8
Dry bulb('F) 35 91 Infilt ation:
Daily range(°F) - 17 ( M )
Vlktbuib(°F) - 77
Wind speed(mph) 15.0 7.5
OWE
HourlyGlazing Load
12,000-
10,000--
9, ,
7,000-
6 �
5,
4,ODO-
3,000-
2,
1,
0
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
FbAy AeraW AEDlinit
Maximum hourly glazing load exceeds average by 1911%.
House has adequate exposure diversity(AED), based bn AED limit of 30%.
AED excursion: 0 Btuh
--
.,- T so
Wr7 htft 2012-Aug-2315:28:40
. 9 Right-Sude®Universal 2012 12.0.12 Right J®Mobile Page 1
• C:%WNDOWSITBMP%wstmplcbde8a05-a4fb-42db-bd3ealb64ft2cOaa.rup Calc=MJ8 Front r faces: W
it "Icill
sual ■ ,
www.ahridirectory.org
Certificate of ProduciRatings
AHRI Certified Reference Number: 4611714 Date: 8/24/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 13HPX-030-230-17
Indoor Unit Model Number: CBX27UH-030-230*+TDR
Manufacturer: LENNOX INDUSTRIES, INC.
Trade/Brand name: 13HPX SERIES
Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 30800
EER Rating (Cooling): 11.50
SEER Rating (Cooling): 14.00
Heating Capacity(Btuh)@ 47 F: 27200
Region IV HSPF Rating (Heating): 8.50
Heating Capacity(Btuh)@ 17 F: 17100
Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless a ompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of Ony kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for m dels and configurations listed in the directory at www.aliridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only a used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;dissemi ted;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential Terence.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.or , Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date n .�
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. and Refrigeration Institute
02012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129902843934078652