Loading...
1751 Beach Ave 2012 New (Main) House �' .�- CITY OF ATLANTIC BEACH r, S) 800 SEMINOLE ROAD j_ --z: ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 _��1i31�� Application Number 12-00000954 Date 2/13/13 Property Address 1751 BEACH AVE Application type description SINGLE FAMILY RESIDENCE Property Zoning TO BE UPDATED Application valuation . . . 1138350 Application desc MAIN HOUSE Owner Contractor GLENN GORDON S & DUNHAM CHRIS GRIDER CONSTRUCTION INC 1751 BEACH AVE 2057 VELA NORTE ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 463-4606 Structure Information 000 000 Construction Type TYPE 5-B Occupancy Type RESIDENTIAL Flood Zone ZONE X Permit ELECTRICAL PERMIT Additional desc . NEW UG SERVICE/ONE METER Sub Contractor . LIMBAUGH ELECTRICAL CONTRAC Permit Fee . . . 205 . 00 Plan Check Fee . . . 00 Issue Date . . . Valuation . . . . 0 Expiration Date . 8/12/13 Special Notes and Comments 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE FOR AN APPROVED FINAL MECHANICAL A/C INSPECTION, A STICKER SHALL BE INSTALLED ON THE AHU TO VERIFY THAT DUCTS HAVE BEEN SEALED, A CERTIFICATION SHALL BE ON SIGHT FOR THE INSPECTOR STATING THAT THE A/C SYSTEM PASSED THE "AIR BLAST INSPECTION" FROM AND INDEPENDENT TESTING AGENCY. *SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST CONTROL COMPANY PRIOR TO C.O. WINDOW AND DOOR INSPECTION: *INSTALLATION INSTUCTIONS REQUIRED *ALL STICKERS ARE TO REMAIN ON THE WINDOWS *PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS Avoid damage to underground water/sewer utilities . Verify vertical and horizontal location of utilities . Hand dig if necessary. If field coordination is needed, call 247-5834 . Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. A sewer cleanout must be installed a the property line . PERMIT IS ielt9N gVtACWRIPAVg4Val Ati,t(13TlablF RiTIANAP�gAreti 2D CLt THE FLORIDA BUILDING CODES. 0� li �t CITY OF ATLANTIC BEACH :-., -j 800 SEMINOLE ROAD - s ATLANTIC BEACH, FL 32233 J ' v INSPECTION PHONE LINE 247-5814 4.14.11119`� Page 2 Application Number . . . . . 12-00000954 Date 2/13/13 Special Notes and Comments metal lid. Cleanout to be set to grade and visible . A reduced pressure zone backflow preventer must be installed if irrigation will be provided or if there is a private well on the property. Backflow preventer must be tested by a certified tester and a copy of the results sent to Public Utilities . If on-site storage is required, a post construction topographic survey documenting proper construction will be required. A Right-of-Way Permit must be obtained for pavers in the right-of-way. A Revocable Encroachment Permit must be obtained for pavers in the right-of-way. Full right-of-way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed on City right-of-way. (Approved: Advanced Disposal, Realco, Shappelle ' s and Waste Management) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities . Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. Other Fees STATE ELEC DCA SURCHARGE 3 . 08 STATE ELEC DBPR SURCHARGE 3 . 08 Fee summary Charged Paid Credited Due Permit Fee Total 205 . 00 205 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 6 . 16 6 . 16 . 00 . 00 Grand Total 211 . 16 211 . 16 . 00 . 00 PERMIT 1S APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 G Ph(904) 247-5826 Fax(904) 247-5845 JOB ADDRESS: 1151 I ( G cJ PERMIT# /2 -qp SEA INFORMATION REQUIRED ON ALL PERMITS (ovlD AMPS WO VOLTS / PHASE VALUE OF WORK$ (4-5-if d62Z) NEW SERVICE ❑ Overhead Underground fl Underground up Pole /tifResidential(Main) Service �� am s #of Meters 00-100 amps 0101-150amps 0 151-200amps P El Commercial(Main) Service 00-100 amps 0101-150amps 0151-200amps ❑ amps OCT Service amps Conductor Type Size CI Multi-Family(Main)Service ❑0-100 amps ❑101-150amps ❑151-200amps ❑ amps # of Unit Meters l(Temporary Pole Cl amps SERVICE UPGRADE ❑ amps ❑ CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) 0 100 amps ❑150amps 0200amps ❑ amps OCT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps 31-100amps ' 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS H Swimming Pool CI Sign Li Smoke Detectors Qty ❑Transformers KVA ❑Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans & Fire Alarm Checklist) VALUE OF WORK$ Qty volts/amps REPAIRS/MISCELLANEOUS HReplace Burnt/Damaged Meter Can ❑Safety Inspection ❑Panel Change ❑OH to UG Li Other: P4) (I f `cE- Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 1-1-(0 - Property Owners Name G Gcrocn Phone Number `'l-r O -4 ���` U BeC1-r(Cat- GC�i lld�hone 24 l-Cl06( Fax Electrical Company`.�,(1'1�U• L k 23 Up" ' i h S reth City Ai ri 1G/1 'CbS tate 1 Zip J Co. Address: �2 W � f / i . State Certification/Regi�,)00??,96 License Holder (Print): ' .'',ii'�'w,c slap t%i�esi _° r� :3m. K i.enn+;b Notarized Signatures _ e - s,oa.D i;41.A'— AC._ C� 20 IS . of .,r»� -,,.- s is r B e d t ,,/ Signature of Notary Public- •