Loading...
435 Osprey Key 2012 HVAC CITY OF ATLANTIC BEACH INOLE ROAD 800 SEM ATLANTIC BEACH,FL 32233 -5814 i'Q INSPECTION PHONE LINE 247 Application Number . . . . . 12-C 0001153 Date 9/04/12 Property Address . . . . . . 435 OSPREY KEY Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0------------------------------ ---------------------------------------- ------ Application desc 1 CU 1 AHU -------------- -- ------------------------------------ --------------------- Owner Contractor ------------------------ ------------------------ WHITLEYS HEATING AND AIR LLC HICKEY MICHAEL J ET AL FRITTS SARAH A R/S 6299-16 POWERS AVE 435 OSPREY KEY JACKSONVILLE FL 32217 ATLANTIC BEACH FL 322334367 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . - 75 . 00 Plan Check Fee . 00 Permit Fee . . . . Valuation . . . . 0 Issue Date . . . . I Expiration Date - - 3/03/13 -------------------- -------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 --------------------------------------- ------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- --- ------- ---------- ---------- Permit Fee Total 75 . 00 75 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 79 . 00 79 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY 01 ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT, APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, Fl, 32233 Ph (904) 247-5826 Fax (9 14) 247-5845 JOB ADDRESS: PERMIT# PROJECT VALUE $ 1000 - 90 ARI# 3i� REQUIRED NEW AIR CONDITIONING & HEATING SYSTEAI INSTALLATION -- -1 9 Air Conditioning: Unit Quantity ons Heat: Unit Quantity BTU's Per nit Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ,t �L I � Air Conditioning: Unit Quantity Tons Per Un Seer Rating Heat: Unit Quantity BTU'sPerLnit 3ocau Duct Systems: Total CFM REQUIRED FIRE PREVENTION (Requires 3 sets of plans) Fire Sprinkler System Quantity Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity — (Requires 3 sets of plans) Commercial Hoods Quantity _ (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Autc mobile Lifts BTU's Gas Piping Outlets Boilers Elevators/Escalators ALL OTHER GAS PIPING Heal Exchanger Quantity of Outlets Pum Ps #Vented Wall Furnaces Reffigerator Condenser BTU's # Water Heaters Sola Collection Systems Tani (gallons) Wel s OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Sa/ra-A llic,,feJ —PhoneNumber V Mechanical Company kAM444 N� C Office Phone Fax_ Co. Address: Puly&W 144& city State F�- Zip 3��17 License Holder(Print): Raqtrandl Staq e Certification/Registration CAC 19(6 YY I t Notarized Signature of License Ider lea, Oil' 11 cribed befi�ie e this day of 20 S 1Hft41RT7=, Sul I N#DD 9677to 0M 10 ocif tary Pu i-- ary pubiic underwritefs &%�'d'Thf,j Not Summary Load Calculations Hickey 435 Osr)rey K-, Atlantic Beach FL Summer Infiltration for the ENTIRE House 0.5 7AC/HR rl.Air Changes per hour(.30 RNC or .50 for AOR) I 21600 Cu. Ft. 1800 x 12 SQ FT Ceiling Hg ,3.Total Infiltration 0.5 x 21600 Cu.Ft X 0.0167 180 CFM Summer Infiltration Room Temperature 20 0 F 1. Design Temperature Difference= Summer Design - 180 CFM 2. Total Infiltration 3968 Btuh 3. Sensible Gain Latent Infiltration Gain for the Entire House 1. Grains of Moisture Difference from Table 1 60 grains] CFM 2. Total Infiltration 180 13. Total Infiltration Load F 7359 Equipment Sizing Calculation Number of (Two People Per Bedroom) Bedrooms 2 Number of Applicances 3 Latent Load for Appliances and People 4520 _People Latent Infiltatrion Load 7359 Latent Equipment Sizing Load 11879 Btuh Heating Summary Design Heating Load Requirements 235 Btuh (Total Heat Loss for Entire House) Total Sensible Gain Cooling Summary 1580� Btuh Total Latent Gain 11 87��- —Btuh Total Btuh (required)= Sensible+ Latent or 27678 Btuh Minimum Total Cooling Tonnage 2.3 Allowable 25% increase 2.9 Square Feet Per Ton 780 Self Training Own all CERTIFIEDTM www.a h ri dire cto ry.a rg A Certificate of Product Ratings AHRI Certified Reference Number: 3699906 Da:e: 9/4/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 213BN(A,W)030****A Indoor Unit Model Number: F134CNF030 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY 13 PURON HP Manufacturer responsible for the rating of this system coml ination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/24C-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating E ccuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (13tuh): 30000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 30000 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh)@ 17 F: 18300 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,Lines accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed an this Certificate and makes no representat ons,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only fo,models and configurations listed in the directory atwww.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall oi ily be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;diss mated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confiden jai reference. CERTIFICATE VERIFICATION . hridirector org Air-Conditioning,Heating, The information for the model cited on this certificate can be verified at www a V click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the c ate on AM 00 ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is lie ted below. @2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 129912426048516484