Permit 632 Main St 1 CU 1 AHU CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
-5814
INSPECTION PHONE LINE 247
Application Number . . . . . 12-00001221 Date 9/13/12
Property Address . . . . . . 632 MAIN ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU
----------------------------------------------------------------------------
Owner Contractor
------------------------
------------------------
CHIMUMENTO MATTHEW ETAL& LAURA ONE HOUR AIR
632 MAIN ST 1015 ATLANTIC BLVD #249
ATLANTIC BEACH FL 322332532 ATLANTIC BEACH FL 32233
(904) 222-8482
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/12/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: 1-3"Z CaM<ff L119 PERMIT#
0 -
PROJECT VALUE $ ARI# �j 7LIA 5-0
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit pnc eA,(!5,(f 0
Heat: Unit Quantity BTU's Per Unit Seer Rating 1 -3
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name fil/nWec,(i c4lumetu—rc) Phone Number
Mechanical Company e�)� Houa, P) I-, —Office Phone2 Ll 1-316?Fax 24 7-5 5-26
Co. Address: eft:7 City/�� Statea _77
11?9 fi�,'A)jLotz r �� - I -zip32 2
License Holder (Xint): /Z X4(6 L_j)Q �Z State C fi ion/Registration#ClKt
7:41
Notarized Signa# Ider
J
C 0mus",
llmuss/ an ubscribed bq� e day of (iio 7- 20 )2-
U
tary p ary 14 lic
2
Se f Notary Public A
Job: 120007
wrightsoft- Project Summary Date: 9M2120`12
Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAG1814420
Project Information
For: MATTHEW& LAURA CHIUMENTO
632 MAIN ST,ATLANTIC BEACH, FL 32233
Phone: 904-728-3232
Notes:
Y
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 oF
Inside db 70 'F Inside db 75 *F
Design TD 35 *F Design TD 16 *F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24827 Btuh Structure 22334 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 24827 Btuh Use manufacturers data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 22334 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2713 Btuh
Ducts 0 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft� 1376 1376 'Equipment latent load 2713 Btuh
Volume(fF) 11008 11008 25048 Btuh
Air changes/hour 0.45 0.23 Equipment total load 2.4 ton
Equiv.AVF(cfm) 83 42 Req.total capacity at 0.76 SHR
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade ONE HOUR AIR Trade ONE HOUR AIR
Model GSZ130301 Cond GSZ130301
AHRI ref 4248582 Coil
AHRI ref 4248582
Efficiency 0 HSPF Efficiency 13 SEER
Heating input Sensible cooling 21612 Btuh
Heating output 0 Btuh @ 47*F Latent cooling 6788 Btuh
Temperature rise 0 'F Total cooling 28400 Btuh
Actual air flow 1017 cfm Actual air flow 1017 cfm
Air flow factor 0.041 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.89
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2012-Sep-12 12:40:58
wrightSOM Right-SuiteO universal 2012 12.0.13 Right JO Mobile Page I
.Z&C:\WNDOWS\TEMPkwstfnp\ec6al b91-73f5-43d4-b21 e-7b544be55627.rup Calc=MJ8 Front Door faces: E
Ulm
~ smal CERTIFIEDT.
ww w.a h r i d i rectory.a rg 'A
Certificate of Product Ratings
AHRI Certified Reference Number: 4248582 Date: 9/13/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ130301A*
Indoor Unit Model Number: AR*F303016C*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 28400
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 26400
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh)@ 17 F: 16000
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis,Certificate may not,in whole or in pan,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION www.ahridirectory.org, "IMP A'-Conditioning,Heating,
The information for the model cited on this certificate can be verified at
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on 00 ILI an'rd Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129920158237051322