Loading...
Permit HVAC 114 Fleet Landing Blvd 2012 S CITY OF ATLANTIC BEACH 1 j 800 SEMINOLE ROAD J ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001315 Date 9/17/12 Property Address . . . . . . 114 FLEET LANDING BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC RETIREMENT FOUNDATION, INC 6491 POWERS AVENUE 1 FLEET LANDING BLVD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 322334599 (904) 724-7211 --- ------------------------------------------------------------------------ Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/16/13 ----------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 i PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. i MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 .TOB ADDRESS: 1- QIPP 4- L n� I tt5 i�aulkslc,e:) t5-ec.r ,_jQPERMU# 3Z23� PROJECT VALUE $ `35'00 ARI# 15`35T,1g Z REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity i Tons Per Unit 3 Heat: Unit Quantity / BTU's Per Unit3!�oo a Seer Rating 13 Duct Systems: Total CFM REQUIRED FIRE PREVENTION -- Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hpse Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: �n ► ���� Permit becomes 1void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application ind know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name PA C� c 4 � d Phone Number 299Gc Mechanical Company Dr, (�,. �,, �.(ec, ,�, �Tf-h v, enc Office Phone it Fax Co. Address: / c w P c City )cLc1c cG�1��1�� State C--t— Zip r2-z-/ License Ho ►�i'Ip414: State Certification/Registration# C OC c S;&ec Notariz ,�� ense Holder r t-/'er+ :• YComm,Expwa: Sworn and subscribed before 7his C11�= day o 20 P, Uenuary 10,p0 * 14 N: + No.°D X13 Signature of Notary Public ','','' I//OFfN V-,.%```,`` ` Right J®Mobile Report Job: wrigh�f Date: 9/14/2012 Entire House By: David Gray Heating and Air, INC. 6491 powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit#114,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified Wetbulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftZ Btuh %of load Walls 8.3 12641 41.2 Ir6thAcrt Glazing 19.7 3320 10.8 Doors 13.5 433 1.4 Ceilings 1.7 2438 8.0 VAI Floors 6.2 8963 29.2 Rws Infiltration 2.1 2869 9.4 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 aajr0 Cihrgs Adjustments 0 Total 1 30663 100.0 Cooling Component Btuh/ftz Btuh %of load VNalls 4.1 6169 27.0 Glazing 47.6 8010 35.1 Intel Chins Doors 11.4 367 1.6 V\Itjl Ceilings 2.6 3720 16.3 Irfiltraticn Floors 0 0 0 Infiltration 0.5 691 3.0 Ducts 0 0 Ventilation 0 0 Wings Internal gains 3860 16.9 blower 0 0 Qha Adjustments 0 aaiing Total 22817 100.0 Latent Cooling Load= 1784 Btuh Overiall U-value=0.147 Btuh/ftz-°F Data entries checked. v�rri htfiC 2012-Sep-14 07:30:18 Right-Suitee Universal 2012 12.0.13 Right JS Mobile Page 1 AMA C:\WINDOWS\TEMP\wstmp\445859bb-db60-4959-8bd3-d78a70c40cd2.rup Calc=MJ8 House Front faces: N I i i I i yytsarft Project Summary Job: Entire House Byte: 9/14/2012 David Gray Heating and Air, INC. 6491 powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rcabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#114,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F i Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 30663 Btuh Structure 22817 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30663 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22817 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1784 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1438 1438 Equipment latent load 1784 Btuh Volume(ft') 10066 10066 Air changes/hour 0.45 0.23 Equipment total load 24601 Btuh Equiv.AVF(cfm) 75 39 Req. total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Trade Model ARUF36C Cond GSZ13036 AHRI ref Coil AHRI ref Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1039 cfm Actual air flow 1039 cfm Air flow factor 0.034 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.93 i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WTi. htss3tt' 2012-Sep-14 07:30:18 Q Right-Suitee Universal 2012 12.0.13 Right J®Mobile Page 1 C:\WINDOWS\TEMP\wstmp\445859bb-db60-4959-8bd3-d78a70c40cd2.rup Calc=MJ8 House Front faces: N weigh Right-J@ Worksheet Job: Entire House Date: 9/14/2012 By: David Gray Heating and Air, INC. 6491 powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... 1 Room name Entire House First Floor 2 Exposed wall 190.8 ft 190.8 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 1438.0 ft 5 Room area 1438.0 f t' 1438.0 f t' Ty Construction U-value Or HTM Area (f t2) Load Area (ft') Load number (Btuh/ft2-°F) I (Btuh/ft2) I or pedmeter (ft) I (Btuh) I or perimeter (ft) ( (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 615A-2s3oc-2 0.269 ne 8.35 4.09 612 551 4603 2256 - 612 551 4603 2256 1D-c2ow 0.570 no 19.72 46.75 61 0 1200 2844 61 0 1200 2844 15A-2s3oc-2 0.269 se 8.35 4.10 234 212 1767 867 234 212 1767 867 1D-c2ow 0.570 se 19.72 49.18 22 0 444 1107 22 0 444 1107 11 M/ 15A-2s3oc-2 0.269 s 8.364.09 25 23 192 94 25 23 192 94 L--G 1D clow 0.570 s 19.72 25.16 3 0 49 63 3 0 49 63 15A-2s3oc-2 0.269 sw 8.29 4.01 594 504 4183 2024 594 504 4183 2024 1D-c2ow 0.570 sw 19.72 49.18 57 0 1134 2828 57 0 1134 2828 11D0 0.390 sw 13.49 11.43 32 32 433 367 32 32 433 367 15A•2s3oc-2 0.269 nw 8.35 4.09 252 227 1896 929 252 227' 1996 929 I 1D-c2ow 0.570 nw 19.72 46.75 25 0 493 1169 25 0 493 1169 C 16B-19ad 0,049 1.70 2.59 1438 1438 2438 3720 1438 1438 2438 3720 j 22A-cph 1.358 46.99 0.00 1438 191 6963 0 1438 191 8963 0 I f f 6 c)AED excursion 0 10 Envelope loss/gain 1 27794 18267 1 1 27794 18267 12 a) Infiltration 2869 691 2869 691 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 30663 22817 30663 22817 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30663 22817 30663 22817 15 j Duct loads 0% 0% 0 0 0% 0% 0 0 1 Total room load 1 1 1 306631 228171 1 1 306631 22817 1 Air required(cfm) 1039 1039 1039 1039 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i ., 2012-Sep-14 07:30:18 Right-Suite®Universal 2012 12.0.13 Right JO Mobile Page 1 C:\WINDOWS\TEMP\wstmp\445859bb-db60-4959-8bd3-d78a70c40cd2.rup Calc=MJ8 House Front faces: N i Component Constructions Job: -� +�����i �f P Date: 911412012 Entire House By: David Gray Heating and Air, INC. 6491 powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Livens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#114,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling 'Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 'Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Method Simplified Wetbulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/R'-°F f?-°F/Btuh Btuh/W Bluh Bluh/fl' Btuh Walls 15A-2s3oc-2:Bg wall,heavy dry or light damp soil,empty core, ne 551 0.157 2.0 8.35 4603 4.09 2256 concrete block wall,r-2 ins,10"thk se 212 0.157 2.0 8.35 1767 4.10 867 s 23 0.157 2.0 8.35 192 4.09 94 sw 504 0.157 2.0 8.29 4183 4.01 2024 nw 227 0.157 2.0 8.35 1896 4.09 929 all 1517 0.157 2.0 8.33 12641 4.07 6169 Parliitions (nono) Windows 1 D-clow:2 glazing,clr outr,air gas,wd frm mat,clr innr, 1/4"gap, ne 61 0.570 0 19.7 1200 46.8 2844 1/8"thk se 23 0.570 0 19.7 444 49.2 1107 s 3 0.570 0 19.7 49 25.2 63 sw 58 0.570 0 19.7 1134 49.2 2828 nw 25 0.570 0 19.7 493 46.8 1169 all 168 0.570 0 19.7 3320 47.6 8010 Doors 11 D0:Door,wd sc type sw 32 0.390 0 13.5 433 11.4 367 Ceilings 1613-1 9ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins, 1/2" 1438 0.049 19.0 1.70 2438 2.59 3720 gypsum board int fnsh Floors 22Acph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 191 1.358 0 47.0 8963 0 0 2012-Sep-14 07:30:19 wr1!9ht,' Oft" Right-Suite®Universal 2012 12.0.13 Right J®Mobile Page 1 ACpk C:\WINDOWS\TEMP\wstmp\445859bb-db60-4959-8bd3-d78a70c40cd2.rup Calc=MJ8 House Front faces: N AED Assessment Job: WgsQ Date: 9/14/2012 Entire House By: David Gray Heating and Air, INC. 6491 lowers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#114, Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling 'Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 .Dry bulb(*F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Wet bu l b(*F) - 77 Wind speed(mph) 15.0 7.5 Test • Adequate Diversity HourlyGlazing Load 10,00 9'00C_ 8,00 7,00 6,00 5,00 4,00 3,00 2,00 1,00 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / F-buiy A,erage / AED limit Maximum hourly glazing load exceeds average by 25.6%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh VkY "l h1ts� F 2012-Sep-14 07:30:19 Right-Suites Universal 2012 12.0.13 Right JS Mobile Page 1 C:\WINDOWS\TEMP\wstmp\445859bb-db60-4959-8bd3-d78a70c40cd2.rup Calc=MJ8 House Front faces: N i i j