Loading...
Permit HVAC 1 Fleet Lainding #122 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD J ATLANTIC BEACH FL 32233 � W INSPECTION PHONE LINE 247-5814 L Jf3 Application Number . . . . . 12-00001348 Date 9/17/12 Property Address . . . . . . 1 FLEET LANDING BLVD MAIN Tenant nbr, name . . . . . . 122 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc REPLACE 3 . 5 TON SYSTEM ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC FLEET LANDING 6491 POWERS AVENUE 1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 32233 (904) 724-7211 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . REPLACE 3 . 5 TON SYSTEM Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/16/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: � �2>°T CG r� ��1� �dk�t'uG rJ`�} .`� �'ur�. f--(PERMIT# ��'l 3T"� 3�7? PROJECT VALUE $ 3 &CO ARI# fl?8;�-L-f REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3, Heat: Unit Quantity BTU's Per Unit 00 a Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to,be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate therovisions of any other state or local law regulation construction or the performance of construction. Property Owners Name t Phone Number? C{6- FQao Mechanical Company Ql,�� n-> Office Phone 72Y?9,11 Fax &V-592, Co. Address: . fcc &2 e a A ti `A:c City .�C c State (::{ Zip 3�2� License Hold Print): �r/'�-� tate Certification/Registration# CfiC c5- /C4 c Notar17Fj',T icense Holder h- OT-4Py�,,�� Q' Sworn and subscribed before me this day of ��/� �r>1.��r- 20 / My Comm.Expires ; G January 10,2014 • No.DD 950813 ; = Signature of Notary Public 4;& N` 1:T mit Right J®Mobile Report Date: 9/17/2012 wrightwsoft Entire House David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904724-5925 Email:rzabinsky@davidgrayonlihe.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#122,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft2 Btuh %of load Walls 8.3 12641 38.8 Ir1ittAm Glazing 31.1 5242 16.1 Doors 13.5 433 1.3 � Ceilings 1.7 2438 7.5 Rays Floors 6.2 8963 27.5 Infiltration 2.1 2869 8.8 Ducts 0 0 Piping 0 0 Humidification 0 0 Oiiirgs Ventilation 0 0 aaJrg Ctlla Adjustments 0 Total 32585 100.0 Cooling Component Btuh/ft2 Btuh %of load Walls 4.1 6169 24.3 Glazing 62.9 10593 41.7 VW Irtwd Cabs Doors 11.4 367 1.4 Ceilings 2.6 3720 14.6 Infiltration Floors 0 0 0 Infiltration 0.5 691 2.7 CdlirT Ducts 0 0 Ventilation 0 0 Internal gains 3860 15.2 Cuter Blower 0 0 Adjustments 0 GEdrig Total 25400 100.0 Latent Cooling Load= 1784 Btuh Overall U-value=0.159 Btuh/ftZ--°F Data entries checked. h. 2012-Sep-17 10:18:36 tSCOft Right-Suite®Universal 2012 12.0.13 Right JS Mobile Page 1 C:\WINDOWS\TEMP\wstmp\982945dc-a618-4787-a384-11747d6f30ff.rup Calc=MJ8 House Front faces: N D y Pro ect Summarat >�rifrhtsof� � •r/ Date: 911712012 al Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#122, Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 35 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 32585 Btuh Structure 25400 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32585 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25400 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1784 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1438 1438 Equipment latent load 1784 Btuh Volume(T) 10066 10066 Air changes/hour 0.45 0.23 Equipment total load 27184 Btuh Equiv.AVF(cfm) 75 39 Req.total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Trade Model ARUF36C Cond GSZ13036 AHRI ref Coil AHRI ref Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 1156 cfm Actual air flow 1156 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.93 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i.. 2012-Sep-17 10:18:36 " wrightSOft Rig ht-Su ite®Universal 2012 12.0.13 Right J®Mobile Page 1 C:\WINDOWS\TEMP\wstmp\982945de-a618-4787-a384-11747d6f30ff.rup Calc=MJ8 House Front faces: N wrWhftcvW Right-M Worksheet Job: Entire House Date: 9/17/2012 By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Livens... 1 Room name Entire House First Floor 2 Exposed wall 190.8 It 190.8 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 1438.0 ft 5 Room area 1438.0 ft' 1438.0 ft' Ty Construction U-value Or HTM Area (f t') Load Area (ft') Load number (Btuh/f t'-°F) I (Btuh/f t') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y/ 15A-2s3oc-2 0.269 n 8.35 4.10 234 212 1767 867 234 212 1767 867 VL 1A-clow 0.900 n 31.14 27.95 22 0 701 629 22 0 701 629 V�/ 15A-2s3oc-2 0.269 ne 8.35 4.09 25 23 192 94 25 23 192 94 � O 1A-clow 0.900 ne 31.14 57.48 3 0 78 144 3 0 78 144 11 T= 15A-2s3oc,2 0.269 a 8.29 4.01 594 504 4183 2024 594 504 4183 2024 1A-clow 0.900 a 31.14 76.06 57 0 1791 4373 57 0 1791 4373 11 D0 0.390 a 13.49 11.43 32 32 433 367 32 32 433 387 yl 15A-2s3oc-2 0.269 s 8.35 4.09 252 227 1896 929 252 227 1896 929 C 1A-clow 0.900 s 31.14 32.80 25 0 778 820 25 0 778 820 Vy 15A-2s3oo•2 0.269 w 8.35 4,09 612 551 4603 2256 612 551 4503 2256 t-G 1A-clow 0.900 w 31.14 76.06 61 0 1894 4627 61 0 1894 4627 C 16B-19ad 0.049 1.70 2.59 1438 1438 2438 3720 1438 1438 2438 3720 F 22A-cph 1,358 46.99 0.00 1438 191 8963 0 1438 191 8963 0 I 61 c)AED excursion 01 1 1 1 0 Envelope losstgain 1 29716 20849 1 1 29716 20849 12 a) Infiltration 2869 691 2869 691 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 32585 25400 32585 25400 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32585 25400 32585 25400 15 Dud loads 0% 0% 0IIToal room load 0 -0% 0% 0 0 Air requi2585 red(cfm) I I I 311561 211561 I I 32585 1156 I 21155661 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. vwright! q 2012-Sep-17 10Pge Right-Suite®Universal 2012 12.0.13 Right J®Ma obile Page 1 ASI C:\WINDOWS\TEMP\wstmp\982945dc-a618-4787-a384-11747d6f30ff.rup Calc=MJ8 House Front faces: N Component Constructions Job: IAIrightr p Date: 911712012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#122,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value lnsul R Htg HTM toss Clg HTM Gain n' Btuh/ft'-'F fl°-°F/Bluh Btuh/fl' Btuh Bluh/W Btuh Walls 15A-2s3oc-2:Bg wall,heavy dry or light damp soil,empty core, n 212 0.157 2.0 8.35 1767 4.10 867 concrete block wall,r-2 ins,10"thk ne 23 0.157 2.0 8.35 192 4.09 94 e 504 0.157 2.0 8.29 4183 4.01 2024 s 227 0.157 2.0 8.35 1896 4.09 929 w 551 0.157 2.0 8.35 4603 4.09 2256 all 1517 0.157 2.0 8.33 12641 4.07 6169 Partitions (none) Windows 1A-clow:1 glazing,clr glz,wd frm mat,1/8"thk n 23 0.900 0 31.1 701 28.0 629 ne 3 0.900 0 31.1 78 57.5 144 e 58 0.900 0 31.1 1791 76.1 4373 S 25 0.900 0 31.1 778 32.8 820 w 61 0.900 0 31.1 1894 76.1 4627 all 168 0.900 0 31.1 5242 62.9 10593 Doors 11 D0:Door,wd sc type a 32 0.390 0 13.5 433 11.4 367 Ceilings 16121-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins, 1/2" 1438 0.049 19.0 1.70 2438 2.59 3720 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet fir fnsh 191 1.358 0 47.0 8963 0 0 2012-Sep-17 10:18:36 wrightsof't> Right-Suite®Universal 2012 12.0.13 Right J®Mobile Page 1 C:\WINDOWSNTEMPXwstmpN982945dca6l8-4787-a384-11747d6f3Off.rup Calc=MJ8 House Front faces: N . . rwrightsoft AED Assessment Job: Date: 9117/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project For: Fleet Landing 1 Fleet Landing Boulevard-Unit#122,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design • • • Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(TF) 70 75 Elevation: 43 ft Design TD(TF) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Daily range(TF) - 17 ( M ) Wet bu l b('F) - 77 Wind speed(mph) 15.0 7.5 Test for • - • uate Exposure Diversity HourlyGlazing Load 14,00 12,00 10,00 8,00 6,00 4,00 2'00C- 0 L---i 1 1 i 1 1 1 1 1 1 1 -1 8 ,0008 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / I-budy / Aerage / PE11irrit Maximum hourly glazing load exceeds average by 22.3%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh 2012-Sep-17 10:18:36 'w sighftOft' Right-Suite®Universal 2012 12.0.13 Right JO Mobile 1 C:\WINDOWS\TEMP\wstmp\982945dc-a618-4787-a384-11747d6f30ff.rup Calc=MJ8 House Front faces: N