Loading...
Permit HVAC 1651 Sea Oats Dr 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ................ ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001353 Date 9/18/12 Property Address . . . . . . 1651 SEA OATS DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ GRAHAM, DOLARES J TRUST OCEAN STATE HEAT & AIR, INC. 1651 SEA OATS DR 1476 ATLANTIC BLVD. ATLANTIC BEACH FL 322335827 NEPTUNE BEACH FL 32266 (904) 249-8251 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/17/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITV OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECH-A,NIC-AL PERMIT APPLICATION CITY OF ATLAINTIc BEACH 800 Seminole Rd Atlantic Beach. FL 322')3 Ph (904) 24.1-5926 Fax (904) 247-5845 JOB ADDRESS: (a5l PERAUT# 1'2 PROJECT f"AL UE S— 2-Z. 0 b NEWAIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Z-1 - Heat: Unit Quantit�T BTUs Per Unit Seer Ratin.2 Duct Systems: Total CF-N4 RE01TIKED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM ALLATIOI ARI 4 5�2,D Y 0 2 Y 3 . .- k-1-5' �� 'D� � A P-ED ,ir Condidoning: Unit Quantity t Tons Per Unit Ql— L Heat: Unit Quantit-y BTU"s Per Unit 's /t U-,' 7seer Ratincr / S Duct Systems: Total CFM REOLITRED FIRE PREVENTION Fire Sprin1der S-,Tst-_m Quantitv (Requires 3 sets of plans) Fire Standpipt Quantity (Requires 3 sets of plans) Undero-Tound Fire Main. Value (Requires 3 sets of plans) Fire Hose Cabin- s Quantity (Requires 3 sets of plans) Commercial Hoods Quantit�- (Requires 3 sets of plans) Fire Suppression Systems Quantir,, �aequires 3 sets of plansi FIRE PLACES -KISCELLANTEOUS: Prefabricated, Fireplace Qi), Putornobij- TiftS Gas Pipin(, Outlets Boilers BTU's Elevators/E scalators ALL OTHER GAS PIPING Heat Exchanger Quantity or Oudets Pumps �Vented Wall Furnaces Refriaorator Condenser BTUs 4 Water Heaters Solar Collection SN 7 stems Tanks (gallons) Wells OTHER: Permi-becomes void if work does not commence witIft,a six month period or work-is suspended or abandoned for si:�months.I hereby zerrify that 1 have read this application and know the same to be true and correct. All provisions of laws and ordinances 2overning this work-will be complied with whether specified or not. The permit does no'give authority to violate the provisions of anv other state or local,law regulation construction or the perfonnanec olf-construction. Propervy Owners Name 6t,for', cj"� Phone Number 2,y 7- -7(,,-M Mechanical Company CtcajA A- K4, a,4� -O.Tice Phone ZYF-22-Z-) Fax—?e��,69�Y9 Co. Address: /Y 7 4 44Y&,,A'c- 8 1 City 13c,,f, State /q- ZiP 3ZZ-(�� 7�State efficationRe istration 9 C-Atoy9,?i 0 License Holder (Print): 9 Notarized Signature dlicense 90 V M.-0-��Egwlqlgo D0860534 WOrn L91)c' c c 6 methis of (?Vg tm, 2d2, Comm#D Expires 3/Z'2013 Pub ic I Mt m S, ature of Not V -0 Flo rids Notary Assn.,Inc ............... .................. 09/17/2012 07.'54 FAX 9042498949 OCEAN-STATE-A/C ATLANTIC-BEACH la002/003 ACCA Manual "J" Heat Load Calculation Date 09/17/12 Customers Name Graham Location Atlantic Beach Type of ConstrUCtiOn licit Transfer Multipliers Area or BTUH Exposure Notes HEATING COOLING Length ()ross Wall HEATING COOLING 1,667 2,3 Windows North Al, N, 2 29.0 18.0 15 435 240 East A West Al, E& . 2 29.0 46.0' 112 3.248 5,152 South Al, S, 2 29.0 25.,0, 20 580 -Soo 4 Doors Front Solid Wood- Panel 27.0 15,8 t 30 810 474 Patio Solid Wood-Storm 16.4 9.7 so 984 582 1 Other Sida GI Dr, S. 2 32-6 25.1 0 0 0 0 5 Net Wall Area I R- 11, 112"Asp- Brd. 3.2 1.9 1,430 4,576 2,717 Area 2 R- 13, 1/2"Asp. Brd, 3.0 1.8 0 0 Area 3 A- 13, 1/2"Asp. Brd. 3.0 1.6 0 0 6 Ceilings Area I Attie, R-22 1.9 2.1. 1,667 31167 3,501 Area 2 Attic, R- 19 --2.1 2.3 0 0 I Area 3 Attic, R-19 2,1 2,3 0 0 7 Roors Area I Slab 40.5 0.0 167 6,764 0 Area 2 None 0.0 0,0 0 0 a Infiltration Winter Summer Avg ClIng Ht I Poor 1500-2100 1.2 .0.6 9 14,032 12,307 9 Sub Total BTUH Loss 34,596 10 Duct BTUH Loss 1 3.460 11 TOTAL HEATING LOAD 455 12 People and Appliances Bedrooms 3 3.000 13 Sub Total DTUH Gain(Structure) 28,473 14 Duct BTUH Gain Location Attic 15% 4,271 . 15 TOTAL SENSIBLE 32,744 16 Infiltraton Latent Gain Infit. CFM 150 5,213 17 People Latent Gain People 4 2,400 19 TOTAL LATENT 7,613 19 ITotall Cooling Load 1 40,357 09/17/2012 07: 55 FAX 9042498949 OCEAN-STATE-A/C 4 ATLANTIC-BEACH 1a003/003 &JIMP 11 This combination qualifies for a Federal Eneroy IL9 CERTIFIED -, Efficiency Tax Credit when placed In service between Feb 1T,2009 and Doc 31,2011. Certificate of Product Ratings AHRI Certified Reference Number: 5204094 Date: 9/17/2012 Product:Split Sy$%M:Host Pump with Remote Outdoor UnItAir-Source Outdoor Unit Model Number;YHJF4234152 Indoor Unit Model Number:FC/MC46D*MV20D+TXV Manufacturer:YORK BY JOHNSON CONTROLS Trade/Brand name: LX SERIES Manufacturer responsible for the rating of this system combination Is YORK BY JOHNSON CONTROLS Rated as follows In accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditloning and AJr-Soume Heat Purnp Equipment and subject to verificaltion of rating accuracy by AHRI-sponsored,independent,third party Noting: Cooling Capacity(13tuh)* 41000 EER Rating(Cooling): 12.50 SEER Rating(Cooling); 15-00 Heating Capadty(Btuh)@ 47 F: 38500 Region IV HSPF Rating(Heating): 9.00 Heating Capacity(Stuh)G 17 F: 26200 Ratings NoWed by an asW*k r)kwicate a vokiniary rersie aprevicuoy published datL unlema sommpenied wvilh a WAS,wNch Indicates an Wmiuntery rerats, DISCLAIMER ANIN does not andou the produagal bud an No CoM end makes no represmadons,warranties or guarantees as to,and aswnso no resoonsiblifty lbr, ft produg;o�Maud an this Cardnazzo.AMN expo aWy dineWme id!liability for dernaM ofany kind orizing out at the we or pm fai n once of as produego),or ths unputwized afterailon of data IMW on this Certillasits.Carffied ragnp oft Yalld only for models and cofflIgurnono Nast!In the directory at wwwAhTkanscIoryorg. TERMS AND CONDITIONS This C*dflcaw and ft-Won's are proprietwy products otANRL This Cwdffcm shall only be used for individual,pamnal and confidandid reference purMea_ The conterin orthk ceffwAa may no�in whole or in Per%be reproduced;coplod;disseminated,entered iyft 3 compuleirdatabou;oratherwim u011ized,in any im or momw or by ow masm sucept for ihe wwo inonmuid,personal and conlIdentm oft now. CERTIFICATE VERIFICATION The Inhwmation for On moW cited on thbi cartific4ar,ow be verified at wwwshildiracury.orl. Air-conditioning.Heating. click an"Veft CrOlkaffie Ink end~11he AHFd Certified Relamcs,Number and Me Onto an 0AWOLEMU and Refrigeration Inafflute which the cordficate was issued which Is Isted above,and the Cartilio No.,which Is lhmd below. 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.; 1299236734324w235