Permit HVAC 1652 Coquina Pl 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001366 Date 9/19/12
Property Address . . . . . . 1652 COQUINA PL
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------
------------------------
KNIGHT HUXHAM HEATING & AIR
2101 FLORIDA BLVD.
ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266
(904) 246-6721
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/18/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT' IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: A2sa C-0Qj1- rUA- P�kr–rr-- PERMIT#
PROJECTVALUEs ARI 139 0(:p
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU'sPerUnit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit 9-5
Heat: Unit Quantity I BTU's Per Unit 9,9,itoip Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Phone Number
Mechanical Company �,L —OfficePhone)�6�7-1/ Fax
Co. Address: a to I r1vevr)4 city lV6 State J!�/ Zip—LV 6 6
License Holder(Print): Y:.-�� Gr:SYDL,� I State Certification/Registration#446CL�M13
Notarized Signature of License;VqKe--r-�' 1.
S S w
wo and subscribed before me this day of 20
0
112 ur of
gnature of Notary Public
Job: 91612
Project Summary Date: Sep 16,2012
Entire House By: ERIN RODRIGUEZ
Project Information
For: KNIGHT
1652 COQUINA PLACE,ATLANTIC BEACH, FL 32233
Notes: HUXHAM-A/C INSTALL
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 92 OF
Inside db 68 OF Inside db 76 OF
Design TD 29 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 56 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 13909 Btuh Structure 13222 Btuh
Ducts 3422 Btuh Ducts 4729 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 17331 Btuh Use manufacturer's data n
Rate/swing multiplier 0.97
Infiltration Equipment sensible load 17412 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1358 Btuh
Ducts 1165 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft') 836 836 Equipment latent load 2523 Btuh
Volume (ft) 6688 6688
Air changes/hour 0.61 0.32 Equipment total load 19935 Btuh
Equiv.AVF (cfm) 68 36 Req.total capacity at 0.70 SHR 2.1 ton
Heating Equipment Summary Cooling' Equipment Summary
Make Bryant Make Bryant
Trade ASPEN Trade ASPEN
Model 213BNA030****A Cond 213BNA030****A
AHRI ref no. 3699906 Coil FB4CNF030
AHRI ref no. 3699906
Efficiency 7.7 HSPF Efficiency 10.8 EER, 13 SEER
Heating input Sensible cooling 20860 Btuh
Heating output 30000 Btuh@47'F Latent cooling 8940 Btuh
Temperature rise 27 OF Total cooling 29800 Btuh
Actual air flow 993 cfm Actual air flow 993 cfm
Air flow factor 0.057 cfm/Btuh Air flow factor 0.055 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.88
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2012-Sep-17 22:58:27
-r1w wrightsOft" Right-Suite@ universal 2012 12.0.07 RSU01508 Page I
....\erin\Documents\wrightsoft HVAC\Ternplate\HUXHAM-KNIGHT.rup Calc=MJ8 Front Door faces:
CERTIFIEDTM
www.ahridirectory.org
Certificate of Product Ratings
AHRI Certified Reference Number: 3699906 Date: 9/19/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 213BN(A,W)030****A
Indoor Unit Model Number: FB4CNF030
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: LEGACY 13 PURON HP
Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 30000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 30000
Region IV HSPF Rating (Heating): 7.70
Heating Capacity(Btuh)@ 17 F: 18300
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed an this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents ofthis Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org, "IMP, Air-Conditioning,Heating,
click on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on AM ON Al and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
@2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 129925336678693460