Loading...
Permit HVAC 5705 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001369 Date 9/19/12 Property Address . . . . . . 1 FLEET LANDING BLVD MAIN Tenant nbr, name . . . . . . 5705 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc CHANGE OUT 3-TON SYSTEM ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC FLEET LANDING 6491 POWERS AVENUE 1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 32233 (904) 724-7211 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . CHANGE OUT 3-TON SYSTEM Permit Fee . . . . 87 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/18/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 87 . 00 87 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 91 . 00 91 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 12-13( ,- Ph Z13( ,-Ph(904)�J247-5826iFax (904)247-5845 f .TOB ADDRESS: - �'I e� �2,►�d o t�. i>at�Ip Jc�t d OG"4c 6e&L In . f�7 L PERMIT# 3z�3� PROJECT VALUE $ '3 15- aa ARI# 5Y 397-92 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating; Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity i Tons Per Unit 3 Heat: Unit Quantity l BTU's Per Unit acc Seer Rating 13 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace QtyAutomobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: — , , 'I- A= Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Y6--Ke 0 Mechanical Company N,,,v i era 1:,!=4 _ L f LA C Office Phone Co. Address: 6YU/ owe(s Ain tAe City 7&CkI0,ly, (fe State-��Zip�/-Z 7 License Holder 1§0 0 w rtr wcke, ertification/Registration# C AC O S7l 8 c Notarized S �, "vfs Holder My Comm,Expl es ; = Sworn and subscribed before ms day of 20J2 January 10,2014 ; • No.DD 950913 ' Nom; Signature of Notary Public 7 q-,e, a twL pUBLAG " F`pLN ���nm11110 `� . wrightsof Right J@ Mobile Report Date: 9/19/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5705,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange (°F) - 17 ( M ) Method Simplified Wet bulb(OF) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh %of load Walls 8.3 12641 38.8 NfiltAcn Glazing 31.1 5242 16.1 Doors 13.5 433 1.3 Vel Ceilings 1.7 2438 7.5 AMS Floors 6.2 8963 27.5 Infiltration 2.1 2869 8.8 Ducts 0 0 Piping 0 0 Humidification 0 0 Calirgs Ventilation 0 0 Q�RJ Ctl1 r Adjustments 0 Total 1 32585 100.0 Cooling Component Btuh/ft2 Btuh %of load Walls 4.1 6169 24.9 Glazing 59.1 9954 40.2 lite, Gins Doors 11.4 367 1.5 V\01 Ceilings 2.6 3720 15.0 IrfiltrEticn Floors 0 0 0 Infiltration 0.5 691 2.8 Ceilinc,is Ducts 0 0 Ventilation 0 0 Internal gains 3860 15.6 QI1�x Blower 0 0 Adjustments 0 aaarg Total 1 1 24761 1 100.0 Latent Cooling Load = 1784 Btuh Overall U-value=0.159 Btuh/ft2-°F Data entries checked. W � hj�r(f 2012-Sep-1908:52:32 Right-Suite®Universal 2012 12.0.13 Right JO Mobile Page 1 C:\WINDOWS\TEMP\wstmp\67979a5e-7775-4945-a238-9c6463ac70b0.rup Calc=MJ8 House Front faces: N Project Summary Job. Wrightsoft- Date: 9/19/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5705,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 32585 Btuh Structure 24761 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32585 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24761 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1784 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ftJ 1438 1438 Equipment latent load 1784 Btuh Volume (fP) 10066 10066 Air changes/hour 0.45 0.23 Equipment total load 26545 Btuh Equiv.AVF (cfm) 75 39 Req.total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Trade Model ARUF36C Cond GSZ13036 AHRI ref Coil AHRI ref Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1127 cfm Actual air flow 1127 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.93 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .:- wri htS40f°t' 9 2012-Sep-19 08:52:32 4d6Ri ht-Suite®U Universal 2012 12.0.13 Right J®Mobile 5k C:\1MNDOWS\TEMP\wstmp\67979a5e-7775-4945-a238-9c6463ac70b0.rup Calc=MJ8 House Front faces: N Page 1 wriightsCtft Right-M Worksheet Job: Entire House Date: 9/19/2012 David Gray Heating and Air, INC. By: 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... 1 Room name Entire House First Floor 2 Exposed wall 190.8 ft 190.8 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 1438.0 ft 5 Room area 1438.0 ft' 1438.0 ft2 Ty Construction U-value Or HTM Area (ft) Load. Area (f t') Load number (Btuh/ft °F) (Btuh/f N) I or perimeter (ft) (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vj/` 15A-2s3oc-2 0.269 ne 8.35 4.09 252 227 1896 929 252 227 1896 929 7A-clow 0.900 ne 31.14 57.48 25 0 778 1437 25 0 778 1437 15A-2s3oc-2 0.269 se 8.35 4.09 612 551 4603 2256 612 551 4603 2256 1A-clow 0.900 se 31.14 60.26 61 0 1894 3666 61 0 1894 3666 11 15A•2s3oc-2 0.269 sw`. 8.35 4.10 234 212 1767 867 234. 212' 1767 -867 r--G1A-clow 0.900 sw 31.14 60.26' 22 0 701 1356 22 0 701 1356 V)/ 15A-2s3oc-2 0.269 w 8.35 4.09 25 23 192 94 25 23 192 94 I-.-G 1A-clow 0.900 w 31.14 76.06 3 0 78 190 3 0 78 190 15A-2s3oc-2 0,269 nw 8.29 4.01 594 504 4183 2024 594 504 4183 2024 IA-clow- 0.900 my 31.14 57.48 57 0 1791 3305 57 0 1791 3305 11D0 0,390 nw 13.49' 11.43 32 32 433 367 32 32 433 367 C 16B-19ad 0.049 1.70 2.59 1438 1438 2438 3720 1438 1438 2438 3720 F 22A-cph 1.358 46.99 0.00 1438 191 8963 0'' 1438 191 8963 0 6 c)AED excursion 0 1 10 Envelope loss/gain 1 29716 20210 1 1 29716 20210 12 a) Infiltration 2869 691 2869 691 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 32585 24761 32585 24761 Less external load 0 0 0 0 Less transfer 0 '', 0 0 0 Redistribution 0 0 0 0 114 Subtotal 32585 24761 32585 24761 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Air al roomrequiiredl(cfm) I I I oad 321271 21127 I 51154761 1 I 311585 27 I 24761 1127 I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W§P1e�tI#&i?l$` 2012-Sep-1908:52:32 Right-Suite®Universal 2012 12.0.13 Right JO Mobile Page 1 C:\VMNDOWS\TEMP\wstmp\67979a5e-7775-4945-a238-9c6463ac70b0.rup Calc=MJ8 House Front faces: N . . Component Constructions aewrighsoft o : 9/19/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rtabinsky@davidgray°nline.com Web:www.davidgrayonline.com Licens... Project • • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit#5705,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(T) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area Ll-value Insul R Htg HTM Loss Clg HTM Gain ft° Btuh/ft'-°F ft?-°F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh Walls 15A-2s3oc-2: Bg wall,heavy dry or light damp soil,empty core, ne 227 0.157 2.0 8.35 1896 4.09 929 concrete block wall,r-2 ins, 10"thk se 551 0.157 2.0 8.35 4603 4.09 2256 sw 212 0.157 2.0 8.35 1767 4.10 867 w 23 0.157 2.0 8.35 192 4.09 94 nw 504 0.157 2.0 8.29 4183 4.01 2024 all 1517 0.157 2.0 8.33 12641 4.07 6169 Partitions (none) Windows 1A-c1 ow:1 glazing,clr giz,wd frm mat, 1/8"thk ne 25 0.900 0 31.1 778 57.5 1437 se 61 0.900 0 31.1 1894 60.3 3666 sw 23 0.900 0 31.1 701 60.3 1356 w 3 0.900 0 31.1 78 76.1 190 nw 58 0.900 0 31.1 1791 57.5 3305 all 168 0.900 0 31.1 5242 59.1 9954 Doors 11 D0:Door,wd sc type nw 32 0.390 0 13.5 433 11.4 367 Ceilings 1613-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins, 1/2" 1438 0.049 19.0 1.70 2438 2.59 3720 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet flr fnsh 191 1.358 0 47.0 8963 0 0 ,.' 1iltri2012-Sep-19 08:52:33hiQy Right-Suite®Universat 2012 12.0.13 Right J®Mobile Page 1 ACCK C:\WINDOWS\TEMP\wstmp\67979a5e-7775-4945-a238-9c6463ac70b0.rup Calc=MJ8 House Front faces: N AED Assessment Job: W C1t,) 1t ►t)f Date: 9/19/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project Information For: Fleet Landing 1 Fleet Landing Boulevard- Unit#5705,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(T) 35 91 Infiltration: Dailyrange (°F) - 17 ( M ) Wet bulb(°F) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure HourlyGlazing Load 14,00(-- 12,00C 4,0012,00 10,00 8,00 6,00c- 4,00c- 2,00c- 0 ,004,002,000 8 9 10 11 12 13 14 15 1617 18 19 20 Hour of Day / Haxly ` Aerage Z PFDlirrit Maximum hourly glazing load exceeds average by 18.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2012-Sep-19 08:52:33 , •iht Right-Suite®Universal 2012 12.0.13 Right J®Mobile Page 1 C:\WINDOWS\TEMP\wstmp\67979a5e-7775-4945-a238-9c6463ac70b0.rup Calc=MJ8 House Front faces: N''