Loading...
Permit Mech HVAC 1451 Beach Ave 2012 AjX CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001379 Date 9/21/12 Property Address . . . . . . 1451 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc change out 2 ton system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ WATKINS, BROOKS ET AL OCEAN STATE HEAT & AIR, INC. 1451 BEACH AVENUE 1476� ATLANTIC BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 249-8251 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . CHANGE OUT 2 TON SYSTEM Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/20/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI. CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 900 Seminole Rd Atlantic Beach, FL322')3 Ph (904) 247-25926 Fax (904) 247-5845 AL/C........ PERAffr JOB-ADDRESS: j'YA PR OJE CT VAL UE S S-To A.6 6 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION 4 Air CondifLioning: Unit Quantity_ Tons Per Unit Heat: Unit Quantit-y BTU's Per Unit Seer RatinL, Duct S-Ystems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI-11_� Ll cl'9 Air Conditioning: Unit Quantity Tons Per Unit REQUIRED +Quantity I Z Heat: Uni, BTU*s Per Unit 5_ Seor Rating- REQUIRED Duct SS-,stems: Total CFM FIRE PREVENTION Fire S-Drinid- er System. Quantity (Requires 3 sets of plans) Fire St'andpipe Quantit� (Requires 3 sets of plans) Underground Fire'N/lain Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Co=ercial Hoods Quanti-c, (Requires 3 sets of p ans) Fire Suppress'on. SlIstoms Quantity (Requires 3 sets of plans) FIRE PLACES ML'�,CELLANEOUS: Pre-falbricated Fireplace Qty Automobile Lifts Gas P;pini: Outlets Boilers BTUjs Elevators,Escallators �k_LL OTHER GAS PIPING Heat Exchanger Quairdty of Outlets Pumps -l" Ventod Wall -Fumaces Refriaerator Condenser BTU's 4:' WatCr Hcat--rs Solax Collection Systems Tank.s (gallons) 'V�7ells OTHER: 70 No oned for six months. I hereby certif�r that I have read Permit b=7777oid if work does not commence within a six month period or work is suspended or aband this application and know the same to be true and correct. Pdl provisions of laws and ordinances governing this work will be complied with whtthe,-spectfied orna,. The r)e-nut does not give authority to violate the proNdsions ot'any other state or local ImAT regulatior,construction or the performance m"oonstruotion. Property Owners Name ck-'U'o, vooruc""-, PhloneNumber t/&-,Vo2_ -1�7,3 MechanicalCompany 0cca_,,( _K_3Jr_ 2� -Office Phone 2,Y5 -Fax 2—Y5-- 9 V 2 Co. Address: I y 7 G uld State Fz_ Zip 3 z-2-6 License Holder (Print): State cation/Registration 4' C4CO V�31 D Notarized Signature of License Ho r Swo and subscribe�Tbefi _mei6s_�)l dayof 1- P.mogzi Coffirf,#C)OOS60534 e of Notar�, Public 9 J6 Si )y w=03 Assh.,ine $gas ... ACCA Manual "J" Heat Load Calculation Date 09/21/12 Customers Name Voorhees Location Atlantic Beach MType of Construction Heat Transfer Multipliers Area or BTUH Exposure Notes HEATING COOLING Length HEATING COOLING —1 Gross Wall 685 2,3 Windows North Al, N, 2 29.0 15 435 540 East& West Al, E&W, 2 29�O 46.0 32 928 1,472 South Al, S, 2 29.0 26.0 20 580 800 4 Doors Front Solid Wood - Panel 27.0 M8 30 810 474 Patio Solid Wood - Storm 16.4 9.7 60 984 582 Other Sldg GI Dr, S, 2 32.6 25.0 0 0 0 5 Net Wall Area 1 R- 11, 1/2"Asp. Brd. 3.2 1.9 528 1,690 1,356 Area 2 R- 13, 1/2" Asp. Brd. 3.0 1,8 0 0 Area 3 R- 13, 1/2" Asp. Brd. 3.0 1.8 0 0 6 Ceilings Area 1 Attic, R-22 1.9 2.1 685 1,302 1,839 Area 2 Attic, R- 19 2.1 2.3 0 0 Area 3 Attic, R- 19 2.1 2.3 0 0 7 Floors Area 1 Slab 40.5 0.0 167 6,764 0 Area 2 None 0.0 0.0 0 0 8 Infiltration I I Winter Summer Avg Cilng Ht [Po®r 1500 -2100 1.2 0.6 9 6,795 5,963 —9 Sub Total BTUH Loss 20,287 10 Duct BTUH Loss - 1 2,029 11 TOTAL HEATING LOAD 22,315 12 People and Appliances Bedrooms 1 1,800 13 Sub Total BTUH Gain (Structure) 14,826 14 Duct BTUH Gain Location Attic 15% 3,224 15 TOTAL SENSIBLE 181060 16 lInfiltraton Latent Gain Infit. CFM 62 4,142 17 People Latent Gain # People 2 —1,400 19 TOTAL LATENT 7_�,7542 Liq Total Cooling Load 23,592 Certificate of Product Ratin st AHRI Certified Reference Number: 4465699 Date: 9/21/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Sourco Outdoor Unit Model Number: YHJR24S41S3 Indoor Unit Model Number: AHE24B Manufacturer: YORK BY JOHNSON CONTROLS Trade/Brand name: LX SERIES Manufacturer responsible for the rating of this system combination is YORK BY JOHNSON CONTROLS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(13tuh): 24000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F 23000 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh) @ 17 F: 13200 Ratings foliowed by an asterisk indicate a voluntary terate of previously pUblished data,wfles%accoripanied with a VVAS�Wild)indicales an involuntafy ierate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for., the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),or the u a - -y org n uthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at wwouahridireOor TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified Air-Condifioninc �ating, click on"Venf`V Ceftilk�ate"link and enter the AHRI Certified Reference Nuniberand the date on g�Hc I I which the certificate was issued,which is listed above,and the Certificate Nm,which is listed below. IOU 110 ILI and Reffigowtion lnsfitufp Q 2012 Air-Conditioning, Heating, and Refrigeration InStitLIte CERTIFICATE NO.: 129927115335572724