Permit HVAC 617 Paradise Ct 2012 CITY OF ATLANTIC BEAC H
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001396 Date 9/26/12
Property Address . . . . . . 617 PARADISE CT
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . RES SF DISTRICT
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
HEAD, REBECCA ONE HOUR AIR
617 PARADISE CT 1015 ATLANTIC BLVD #249
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 222-8482
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/25/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: Pw An( s -C C I PERMIT#
PROJECTVALUE $ ARI# S q-2 S-i
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit -2 , 5
Heat: Unit Quantity BTU's Per Unit—30 K, Seer Rating--
Duct Systems: Total CFM REQUI—RED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name -36-(T50d
11s)E C—C-C jQ /4,z Phone Number
Mechanical Company L-)&� Office Phone-2'fl-S/07 Fax 2q 7-ss-z6
Co. Address: 1199 M4 W—O!f 7— Cit IhIA&F11r, State 2.zip�3223'�
License Holder(Print): ra�Qlr--, DADOQVlx�l tat on/Registration#C-4-C-L�Tq-y-?C
Notarized Signature of License Holder �tat
Sworn and subscribed befo this day o 20L2.
Signature of Notary P�iblic"'
—U
Project Summary Job: 120205
WrlghtwW Date: 9/25/2012
Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD 01,ATLANTIC BEACH,FIL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
Project Information
For: REBECCA HEAD
617 PARADISE CT,ATLANTIC BEACH, FL 32233
Phone: 904-536-0300
Notes:
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 'F
Inside db 70 'F Inside db 75 'F
Design TD 35 *F Design TD 16 *F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24273 Btuh Structure 23092 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 24273 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 23092 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2749 Btuh
Ducts 0 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area(ft� 1408 1408 Equipment latent load 2749 Btuh
Volume(n 11264 11264
Air changes/hour 0.45 0.23 Equipment total load 25840 Btuh
Equiv.AVF(cfm) 84 43 Req.total capacity at 0.78 SHR 2.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade ONE HOUR AIR Trade ONE HOUR AIR
Model GSZ1 30301 Cond GSZ130301
AHRI ref 5429592 Coil
AHRI ref 5429592
Efficiency 0 HSPF Efficiency 13 SEER
,Heating input Sensible cooling 23490 Btuh
Heating output 0 Btu h @ 47-F Latent cooling 6510 Btuh
Temperature rise 0 'F Total cooling 30000 Btuh
Actual air flow 1051 cfm Actual air flow 1051 cfm
Air flow factor 0.043 cfm/Btuh Air flow factor 0.046 cfm/Btuh
S, tatic pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.89
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wr19htS0f1t* Rlght�SuiteS Universal 2012 12.0.13 Right JO Mobile 2012-Sep-25 12:33:24
Ak C:\WIND0WS\TEMP\%vstrnp\5190a94e-1 ada-4fec-aca4-9812d5343f34.rup Calc=MJ8 Front Door faces: S Page 1
CERTIFIEDTM
www.ahridirectory.org 'A 11
Certificatp- of Product Ratings
AHRI Certified Reference Number: 5429592 Date: 9/26/2012
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ130301A*
Indoor Unit Model Number: ARUF36C14A*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN, JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(13tuh): 27600*
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 27000
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh)@ 17 F: 16400
RatIngs followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form.or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The Information for the model cited on this certificate can be verified at www.ahridirectory.org, A "IMF, Air-Conditioning,Heating,
click r
,on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. SOU an ILI and Refrigeration Institute
@2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129931613169640555