Permit Mech HVAC 450 Mako Dr 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
it
Application Number . . . . . 12-00001191 Date 10/04/12
Property Address . . . . . . 450 MAKO DR
Application type description RESIDENTIAL ALTERATION
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 34200
----------------------------------------------------------------------------
Application desc
KITCHEN & BATH REMODEL
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
MILLER, RICHARD J TRI-H CONSTRUCTION LLC
450 MAKO DR 11215 ST JOHNS INDUSTRIAL PKWY
ATLANTIC BEACH FL 32233 UNIT 10
JACKSONVILLE FL 32246
(904) 545-9978
--- Structure Information 000 000 KITCHEN & BATH REMODEL
Occupancy Type . . . . . . RESIDENTIAL
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc A/C REPLACEMENT
Sub Contractor BRISK AIR HEATING & COOLING
Permit Fee . . . . 79 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 4/02/13
----------------------------------------------------------------------------
Special Notes and Comments
2010 FLORIDA BUILDING CODE, 2008 NATIONA1 ELECTRIC CODE
*REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING
DEPARTMENT IMMEDIATELY.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 79 . 00 79 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 83 . 00 83 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: 4S-O A C1.kO bjr(VC- PERmrr#
PROJECTVALUE $ '41 1(0(�p ARI# 3 �SO � 3 (0
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratina
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM 100 REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name ki-C* hAlk-'r- Phone Number
Mechanical Company RYIS � Air H Ca� AL- (110 kr\�I Tvi(—Office Phone g�0-8q&I Fax ZEKAHO
Co. Address: 4(PV(,P �iJQSSal � DKI'Vc- City )0J(-S6-Y\v(t(C StateP�-T-,Zip 3ZZS-"7
License Holder(Print): 63\1-e� Sarywv-,or-� State Certification/Registration#CftC- (04q 12—
Notarized Signature of License-Aolder
Sworn aiiL�—cribed before me this day of
em.-Utt"Iml
S* 39
#EE 075233
Commission
ExpiresApd14,2015 .7019
Bonded Thru T(W Fain Mumme W385
Oct 04 12 1 1:00a 904-288-0140 P.1
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax(904) 247-5845
JOBADDRESS: 45-0 &AjAkO j)rrVC- PERmrr
PROJECTVALUE $ 4,1(V(P AR1# 3 �S OS
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating_ f
Duct Systems: Total CFM 1Z60 REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Peffnit becomes void if work does not commence within a six ruonth period or work is suspended or abandoned for six months.I hereby ccrtify that I have read
this application and know the same to betruc and correct. All provisions of laws and ordinances govcming this work will be complied with whether specified
or not The pandt does not give authority to violate the provisions of any other state or local law regulation construction or the perron-nance of construction.
Property Owners Name kic� Phone Number
Mechanical Company R n S � 11�i rH ea�r�,� 4e ('dig I t�� inL_Office Phone Fax-ZILONO
Co.Address: ktJCkSSail Dy-)Nf- City StateP�,Zip--37-7-S—q
License Holder(Print): V- sary)rvor-S State Certification/Registration:#CftC I 91LI 112—
Notarized Signature of License older zm--
Sworn WgLi2ribed before me this I day of 20 1
S, 0 Rmluasari"aRk
- t��3
cornmabi#EE
ExpiresApd 4,205
Oct 04 12 11:01a 904-288-0140 p.2
Project Summary Job:
+ wrightsoft, DOW 10fV12
Endre House By: M.Ellis
Energy Design Systems, Inc.
Project Information
For; Miller Residence,Changeout
450 Mako Drive,Atlantic Beach,FL
Notes: Front door faces East.
Design Information
Weather: Jacksonville, Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outr�de db 32 OF Outside db 93 OF
Inside db 72 'F Inside db 72 OF
Design TO 40 *F Design TD 21 OF
Daily range M
Relative humidity 50 %
Moisture difference 58 gr1lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26562 Btuh Structure 22230 Btuh
Ducts 3524 Btuh Ducts 4823 Btuh
Central vent(32 cfm) 1427 Btuh Central vent(32 cfm) 735 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 31513 Btuh Use manufacturers data n
Rallefswin multiplier 0.98
Infiltration Equipme4 sensible load 27121 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces a Structure 2172 Btuh
Ducts 1129 Btuh
HeatM CoolM Central vent(32 cfm) 1273 Btuh
Area(ftJ 1 22 122 Equipment latent load 4574 Stuh
Volume(W) 9792 9792
Air changesihour 0.45 0,23 Equipment total load 31695 Btuh
Equiv.AVF(cfm) 73 38 Req.total capacity at 0.75 SHR 3.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make Goodman Manufacturing Co.,LP Make Goodman Manufacturing Co-, LP
Trade Goodman Trade Goodman
Model GSZ1303618* Cond GSZ1 30361 B*
Coil MBVC1600AA-A
Efficiency 8.2 HSPF Efficiency 14 SEER
Heating input Sensible cooling 24640 Btuh
Heating output 32000 Stuh @ 47*F Latent cooling 10560 Btuh
Temperature rise 25 -F Total coolling 35200 Btuh
Actual air flow 1188 cftn Actual air flow 1188 afm
Air flow factor 0.039 cfm/Btuh Air flow factor 0.1344 cf`m1Btuh
Static pressure 0.00 in H20 Static pressure 0.00 in H20
Space thermostat Load sensible heat ratio 0.86
PrirTtout certified by ACCA to meet all requirements of Manual J Bth Ed.
-Oct-04 09:4152
-f* wwr1gil%t=43,f%-. Right-$Wt@Rosidental6.O.119RSR29784 2012
AM EAF0&C."nW..Wrdl-1 Charvamr!Manual J'Mriak Air,Miller Changeotd,450 Mako Dr.All Bch.rrp Page I