Loading...
Permit Mech HVAC 102 Fleet Landing Blvd 2012 Its CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001451 Date 10/04/12 Property Address . . . . . . 102 FLEET LANDING BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC RETIREMENT FOUNDATION, INC 6491 POWERS AVENUE 1 FLEET LANDING BLVD JACKSONVILLE FL 32217 ATLANTIC BEACH FL 322334599 (904) 724-7211 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/02/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 2/47-5845 JOBADDRESS: I- HPJ n�i►trai l?y�tir-� f'''( tGn is ar� PERMTr# PROJECT VALUE $ �,�Sc> aRI REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: U�Yp l o,2 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name t Phone Number �2�-1 6' 9Qo� Mechanical Company Znc Office Phone Fax 7,2�( -9-S Co. Address: City )6-c. J M,1� ((f State Zip ?Z2�� License Holdup, State Certification/Registration# UC o 5�7/k NotarizedA`• dt • e Holder rte--�/(P� I—V c k6- my Comm. Sworn and subscribed before t3w this �/ day of (!�C 20 Amery 10,2014 •� No.DD 950am Nj�:• Q• Signature of Notary Public c • O` Right J® Mobile Report Date: 10/4/2012 + wflghtsoft- Endre House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904724-7211 Fax:904-724-5925 Email:rzabinsky(Mdavidgrayonline.com Web:www.davidgrayonline.com Licens.:. Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit# 102,Atlantic Beach, FL 32233 Phone:904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD (TF) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange (°F) - 17 ( M ) Method Simplified Wet bulb('F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft2 Btuh %of load Walls 8.3 15133 38.1 IrtIb4am Glazing 31.1 6358 16.0 Doors 13.5 433 1.1 Ceilings 1.7 3879 9.8 VAI Ams Floors 4.7 10713 26.9 Infiltration 2.0 3246 8.2 Ducts 0 0 Piping 0 0 Humidification 0 0 Qaa C.elims Ventilation 0 0 Adjustments 0 Total 1 1 39762 100.0 Component Btu h//fF Btuh %of load Walls 4.1 7389 24.1 Irten-d Lairs Glazing 60.8 12407 40.4 V\till Doors 11.4 367 1.2 Irfiltratirn Ceilings 2.6 5920 19.3 Floors 0 0 0 Infiltration 0.5 765 2.5 Cglirx� Ducts 0 0 Ventilation 0 0 Internal gains 3860 12.6 Cthff Blower 0 0 Adjustments 0 Gaarg Total 1 1 307061 100.0 Latent Cooling Load = 1932 Btuh Overall U-value=0.136 Btuh/ft2-°F Data entries checked. .;� �ril hiFt" 2012-Oct-0405:31:59 r g Rig U niversal 2012 12.0.13 Right J®Mobile Page 1 C:\WNDO\NS\TEMP\wstmp\71al9d54-3feb-4fcl-8aO8-dbfra95ad6eb4.rup Calc=MJ8 House Front faces: N ' Project Summary Job. wrighsoft- Date: 10/4/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit# 102,Atlantic Beach, FL 32233 Phone:904-246-9900 Fax: 904-246-9455 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 35 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 39762 Btuh Structure 30706 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 39762 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 30706 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1932 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ftp 2288 2288 Equipment latent load 1932 Btuh Volume(ft) 16016 16016 Air changes/hour 0.32 0.16 Equipment total load 32638 Btuh Equiv.AVF (cfm) 85 43 Req.total capacity at 0.70 SHR 3.7 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Trade Trade Model ARUF48D Cond GSZ13048 AHRI ref Coil AHRI ref Efficiency 0 AFUE Efficiency 13 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 1398 cfm Actual air flow 1398 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. "` vVih' 1 2012-Oct-04 05:31:59 A+- gi Right-Suite®Universal 2012 12.0.13 Right J®Mobile Page 1 C:\\MNDOWS\TEMP\wstmp\71a19d54-3feb-4fc1-8a08-dbf695ad6eb4.rup Calc=MJ8 House Front faces: N IT wrightsoft, Right-J® Worksheet Date: 10/4/2012 Entire House Dat By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonfine.com Licens... 1 Room name Entire House First Floor 2 Exposed wall 228.0 ft 228.0 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 2288.0 ft 5 Room area 2288.0 ft2 2288.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Bt uh/ft2-°F) (Btuh/ft2) or perimeter (ft) ( (Btuh) or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VjJ 15A-2s3oc-2 0.269 n' 8.35' 4.09 342 308 2571 1260 342 308- 2571 1260 �-( 1A-clow 0.900 n 31.14 27.954 34 0 1064 955 34 0 1064 955 V�/ 15A-2s3oc-2 0.269 a 8.35 4.09 684 616 5141 2519 684 616 5141 2519 C 1A-clow 0.900 a 31.14 76.06 68 0 2128 5197 68 0 2128 5197 11V�( 15A-2s3oc-2 0.269 s 8.35 4.09 342 308 2571 1260 342" 308- 2571 1260 L._G 11A-clow 0:900 s 31.14' 32.80 34 0 1064 1121 34 0 1064 1121 15A-2s3oc-2 0.269 w8.30 4.02 684 584 4850 2350 684 584 4850 2350 1A-clow 0.900 w 31.14 76.06 67 0 2102 5134 67 0 2102 5134 1100 0.390 w 13.49 11.43 32 32 433 367 32 32 433 367 C 168-19ad 6 0:049 1.70 2.59 2288 2288 3879 5920 2288 2288 3879 5920>s F 22A-cph 1.358 46.99 0.00 2288 228 10713 0 2288 228 10713 0 61 c)AED excursion 01 1 1D Envelope loss/gain 1 36516 26082 1 1 36516 26082 12 a) Infiltration 3246 765 3246 765 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 39762 30706 39762 30706 Less ext mal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 39762 30706 39762 30706 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 L I Air requomdl(cfm) ( 1 313981 313981 1 1 31398 1 30308 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ••�•_ w1rigl�tsr oft` 2012-Oct-04 05:31:59 Right-Suite®Universal 2012 12.0.13 Right J®Mobile Page 1 C:\WINDOWS\TEMP\wstmp\71al9d54-3feb-4fcl-8a08-dbf695ad6eb4.rup Calc=MJ8 House Front faces: N Component Constructions Job: - - writ,��1tsoft' Component Date: 10/4/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project • • For: Fleet Landing 1 Fleet Landing Boulevard-Unit# 102,Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Method Simplified VVet bulb(°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area Ll-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/W-°F ft'-"F/Btuh Btuh/ft' Btuh Btuh/ft° Btuh Walls 15A-2s3oc-2:Bg wall,heavy dry or light damp soil,empty core, n 308 0.157 2.0 8.35 2571 4.09 1260 concrete block wall,r-2 ins, 10"thk a 616 0.157 2.0 8.35 5141 4.09 2519 s 308 0.157 2.0 8.35 2571 4.09 1260 w 584 0.157 2.0 8.30 4850 4.02 2350 all 1816 0.157 2.0 8.33 15133 4.07 7389 Partitions (none) Windows 1A-c1 ow: 1 glazing,clr giz,wd frm mat, 1/8"thk n 34 0.900 0 31.1 1064 28.0 955 e 68 0.900 0 31.1 2128 76.1 5197 s 34 0.900 0 31.1 1064 32.8 1121 w 68 0.900 0 31.1 2102 76.1 5134 all 204 0.900 0 31.1 6358 60.8 12407 Doors 11 D0:Door,wd sc type w 32 0.390 0 13.5 433 11.4 367 Ceilings 1613-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins, 1/2" 2288 0.049 19.0 1.70 3879 2.59 5920 gypsum board int fnsh Floors 22A-cph:Bg floor,heavy damp soil,on grade depth,carpet flr fnsh 228 1.358 0 47.0 10713 0 0 2012-Oct-04 05:31:59 '%`��- + WriglhttSO t� Right-Suite®U niversal 2012 12.0.13 Right J®Mobile Page 1 4^ C:\WINDOWS\TEMP\wstmp\71a19d54-3feb-4fc1-8a08-dbf695ad6eb4.rup Calc=MJ8 House Front faces: N AED Assessment Job: ���� � Date: 1014/2012 Entire House By: David Gray Heating and Air, INC. 6491 Powers Avenue,Jacksonville,FL 32217 Phone:904-724-7211 Fax:904-724-5925 Email:rzabinsky@davidgrayonline.com Web:www.davidgrayonline.com Licens... Project Information For: Fleet Landing 1 Fleet Landing Boulevard-Unit# 102, Atlantic Beach, FL 32233 Phone: 904-246-9900 Fax: 904-246-9455 Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature (°F) 70 75 Elevation: 43 ft Design TD (°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange (°F) - 17 ( M ) Wet bulb(°F) - 77 Wind speed (mph) 15.0 7.5 Test for • - • Exposure Diversity HourlyGlazing Load 16,00 14,00 12,00 0,00EI- 8,00T0 6,00 4,00 2,00 08 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Homy / Aerage P®limit Maximum hourly glazing load exceeds average by 20.6%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2012-Oct-04 05:31:59 Right-Suiie®Universal 2012 12.0.13 Right J®Mobile Page 1 C:\\AANDOWS\TEMP\wstmpk7lal9d54-3feb4fcl-8aO8-dbf695ad6eb4.rup Calc=MJ8 House Front faces: N