Loading...
Permit Mech HVAC 381 4th St 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001461 Date 10/08/12 Property Address . . . . . . 381 4TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 -----------------------------------------------I---------------------------- Application desc Change out a 3 ton system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BARTLESON, PATRICIA ONE HOUR AIR 381 4TH ST 1015 ATLANTIC BLVD #249 ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . CHANGE OUT 3 TON PERMIT Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/06/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH PCA SURCHARGE 2 . 00 STATE MECH bBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 q,kf JOB ADDRESS: PERMIT# PROJECTVALUE $ — ARI# 2��:39772— REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escala,tors ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's 4 Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give a rity to violate the provisions of any other state or local law regulation construction or the performance of construction. An * (f, Property Owners Name /-,/9-/7� j3;-r, rj/-L) Phone Number 24 83 // Mechanical Company (�:)ALJP I-10t Y2 611�- Office Phone2t�//-S[Q--� Fax2LO-.5S21� Co. Address: I /Va lj!�6 T /V0 City��Z �("4-/Statej QC Zip 3-2 z 3 1 t t. License Holder(Print): Stat�e Certi JqAlo eys ra ion Notarized Signature of License Holder Sworn and subscribed befor m Zjt�i s a f 20 7d Signature of Notary Publi L D7EB0R7AH AMANDA WHITI,-. My COMMISSKOW U r ter;' &.dd hrUmowyPui)1icunde-' A EXPIRES: T ��P. B=W Thru 6IL- Job: 120333 wrightsoft. Project Summary Date: 1018/2012 Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD#1,ATLANTIC BEACH,FIL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 Project Information For: PATRICIA BARTLESON 381 4TH ST,ATLANTIC BEACH, FL 32233 Phone: 904-249-8391 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 *F Outside db 1 91 *F Inside db 70 *F Inside db 75 'F Design TD 35 *F Design TD 16 *F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29952 Btuh Structure 29135 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29952 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29135 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2749 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft� 1408 1408 Equipment latent load 2749 Btuh Volume(fe) 11264 11264 Air changes/hour 0.45 0.23 Equipment total load 31884 Btuh Equiv.AVF(cfm) 84 43 Req.total capacity at 0.80 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade ONE HOUR AIR Trade ONE HOUR AIR Model GSZ130361 Cond GSIZ130361 AHRI ref 5439792 Coil AHRI ref 5439792 Efficiency 0 HSPF Efficiency 13 SEER Heating input Sensible cooling 26301 Btuh Heating output 0 Btuh @ 47-F Latent cooling 6699 Btuh Temperature rise 0 *F Total cooling 33000 Btuh Actual air flow 1326 cfm Actual air flow 1326 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2012-Oct-08 06:43:08 Page 1 wrightsoft- Right-Suite(ED Universal 2012 12.0.13 Right JS Mobile C:\WNDOWS\TEMP\wstmp\4ad6f267-Oac4-4489-aO45-1 a2969c8b44f.rup Calc=MJ8 Front Door faces: S -HP Search Page I of 2 0 HP S­hh Home 0 Modify L*j Export Double click on a row to view/prmt AHRI certificate. AHRI certificates are not available for Obsolete AC and HIP equipment. Model Status of'Active'means models are currently in production.'Discontinued'means that the manufacturer has elected to stop producing,yet stock is still available.'Obsolete'means that the manufacturer is required to stop manuh Outdoor Unit Indoor Unit Cooling High Heating 47 F Low Heating 17 F AHRI AHRI Model Manufacturer Trade/Brand Manufacturer Model Manufacturer Model Furnace Capacity EER SEER Cap-ity HSPF Capacity(Btuh) Phase HSI Carl Status Type Name (Mix-match) Model (Btuh) (Btuh) Type Ref GOODMAN, JANITROL, AMANA DISTINCTIONS, GOODMAN 33000 8.00 20800 1 HRCU 5439792 Active Systems EVERREST, MANUFACTURING GSZ130361B* ARUF36Cl4A*,TXV 33000 11.00 13.00 -A-CB ONE HOUR AIR CO.,LP. CONDITIONING AND HEATING, ENERGI AIR Now displaying records I-1 of 1 total A I Copyright 0 2012 AW-6inditioning,Heatingi and Refrigea on Institute All rights reserved. http://www.ahridirectory.org/ahridirectory/pages/hp/defaultSearch.aspx 10/8/2012