Permit Mech HVAC 381 4th St 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001461 Date 10/08/12
Property Address . . . . . . 381 4TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
-----------------------------------------------I----------------------------
Application desc
Change out a 3 ton system
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
BARTLESON, PATRICIA ONE HOUR AIR
381 4TH ST 1015 ATLANTIC BLVD #249
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 222-8482
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . . CHANGE OUT 3 TON PERMIT
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 4/06/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH PCA SURCHARGE 2 . 00
STATE MECH bBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
q,kf
JOB ADDRESS: PERMIT#
PROJECTVALUE $ — ARI# 2��:39772—
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating 3
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escala,tors
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give a rity to violate the provisions of any other state or local law regulation construction or the performance of construction.
An * (f,
Property Owners Name /-,/9-/7� j3;-r, rj/-L) Phone Number 24 83 //
Mechanical Company (�:)ALJP I-10t Y2 611�- Office Phone2t�//-S[Q--� Fax2LO-.5S21�
Co. Address: I /Va lj!�6 T /V0 City��Z �("4-/Statej
QC Zip 3-2 z 3
1 t t.
License Holder(Print): Stat�e Certi JqAlo eys ra ion
Notarized Signature of License Holder
Sworn and subscribed befor m Zjt�i s a f 20
7d
Signature of Notary Publi
L
D7EB0R7AH AMANDA WHITI,-.
My COMMISSKOW U
r ter;'
&.dd hrUmowyPui)1icunde-'
A
EXPIRES:
T ��P.
B=W Thru 6IL-
Job: 120333
wrightsoft. Project Summary Date: 1018/2012
Entire House By: CRAIG EDDY
ONE HOUR AIR
1198 MAYPORT RD#1,ATLANTIC BEACH,FIL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420
Project Information
For: PATRICIA BARTLESON
381 4TH ST,ATLANTIC BEACH, FL 32233
Phone: 904-249-8391
Notes:
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 *F Outside db 1 91 *F
Inside db 70 *F Inside db 75 'F
Design TD 35 *F Design TD 16 *F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29952 Btuh Structure 29135 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 29952 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 29135 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2749 Btuh
Ducts 0 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft� 1408 1408 Equipment latent load 2749 Btuh
Volume(fe) 11264 11264
Air changes/hour 0.45 0.23 Equipment total load 31884 Btuh
Equiv.AVF(cfm) 84 43 Req.total capacity at 0.80 SHR 3.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade ONE HOUR AIR Trade ONE HOUR AIR
Model GSZ130361 Cond GSIZ130361
AHRI ref 5439792 Coil
AHRI ref 5439792
Efficiency 0 HSPF Efficiency 13 SEER
Heating input Sensible cooling 26301 Btuh
Heating output 0 Btuh @ 47-F Latent cooling 6699 Btuh
Temperature rise 0 *F Total cooling 33000 Btuh
Actual air flow 1326 cfm Actual air flow 1326 cfm
Air flow factor 0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.91
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2012-Oct-08 06:43:08
Page 1
wrightsoft- Right-Suite(ED Universal 2012 12.0.13 Right JS Mobile
C:\WNDOWS\TEMP\wstmp\4ad6f267-Oac4-4489-aO45-1 a2969c8b44f.rup Calc=MJ8 Front Door faces: S
-HP Search Page I of 2
0 HP Shh
Home 0 Modify L*j Export
Double click on a row to view/prmt AHRI certificate.
AHRI certificates are not available for Obsolete AC and HIP equipment.
Model Status of'Active'means models are currently in production.'Discontinued'means that the manufacturer has elected to stop producing,yet stock is still available.'Obsolete'means that the manufacturer is required to stop manuh
Outdoor Unit Indoor Unit Cooling High Heating 47 F Low Heating 17 F
AHRI
AHRI Model Manufacturer Trade/Brand Manufacturer Model Manufacturer Model Furnace Capacity EER SEER Cap-ity HSPF Capacity(Btuh) Phase HSI
Carl Status Type Name (Mix-match) Model (Btuh) (Btuh) Type
Ref
GOODMAN,
JANITROL,
AMANA
DISTINCTIONS, GOODMAN 33000 8.00 20800 1 HRCU
5439792 Active Systems EVERREST, MANUFACTURING GSZ130361B* ARUF36Cl4A*,TXV 33000 11.00 13.00 -A-CB
ONE HOUR AIR CO.,LP.
CONDITIONING
AND HEATING,
ENERGI AIR
Now displaying records I-1 of 1 total
A I
Copyright 0 2012 AW-6inditioning,Heatingi and Refrigea on Institute All rights reserved.
http://www.ahridirectory.org/ahridirectory/pages/hp/defaultSearch.aspx 10/8/2012