Loading...
Permit HVAC 1085 Atlantic Blvd 63 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001430 Date 10/09/12 Property Address . . . . . . 1085 ATLANTIC BLVD 63 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/07/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION oqb7-eo CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax (904) 247-5845 JOB ADDRESS: 12LT Akaati't, &. 1z �ERMJT# PROJECT VALUE $___,�.7_�7,21, ARI# 14 7 Qe_DC Z-7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems; Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit ')- - Heat: Unit Quantity BTU's Per Unit 5 KLJ SeerRating_- 1,25 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Comincricial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Reffigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or%vork-is suspended or abandoned for six months.I hereby certify that I have rea'( this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company ELLA ; ?_(S 7_ [AQ&4�f1c`ePhon(663- (-IF Co. Address: 47,Z';t, 0-.,/'PL ILI :Rcaj city La-L.-ALoca StateF/ Zip_--e"9tn License Holder(Print):—1 %--rr Lj -Ran,11'el"s State d ification/Registration#d 4-1160 Notarized Signature ofLicense Holde Sworn and sul:rscribed bef e let s I daiv 20k �mp N7AHAM -.0 Signature of Notary Public 14,2014 I oli 1-N, a- www,ahridirectory.org ILT� AIN& uleratifiC.4ate of Product Ratim',ais tj AHRI Certified Reference Number: 4765491 Date: 9/10/2012 Product: Split System:Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX1 30241 C* Indoor Unit Model Number: AR*FI82416C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does nat endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the produegs)listed on this Cortiftate.AHRI expressly disclaims all flablifty for damages of any kind arising out of the use or performance of the product(s).or the unauthorized alteration of data Noted an this Certificate.Certified ratings are valid only for miodeft and configurations listed In the directory at www.a h rid irecto ry.org. TERMS AND CONDITIONS This Certificate and its contents ore proprietary products of AHRL This Cortificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,In whole or In part,be reproduced,copied;disserninatod;entered Into a computer database;or othervAss utilized,In any form or manner or by any means,except for the user's IndividuaL personal and conMentlof reference. CERTIFICATE VERIFICATION The linformation for the modef cited on this cortificate can be verified at wwvv.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"fink and enter the AHRI Cortified Reference Number and the date on an 1ka and Refrigeration Institute which the certificate was issued,which Is Noted above,and the Certificate No,which Is listed below. 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917765623209026 DesignStar Load Calculation Results are intended lbr use with Rheem heating and cooling systems only Tne Now Dogive ol ComforJIO ',Customer Information lvd, DUVAL. FL 32233 _7 tud e Lon .33 75 '1.76W: t ............... ....... ............... House Square Footage: 7,50 sq. ft.. .......... ........ ...... Name: Terr�.Runnels .......... ........................ .............. ............... ................. ........ ...... ...... Phone: 863-5-81-4268 ............ ....... ....... .... ........... ........ ...... ..................... ------ ............... Email: terunsr@aol.com ............................... ....................... .............- .......... ........... :House Information SHR .75 .................. ........ ............. ............................... Number of residents. 4, .....................- ........... ...... ............. Ceiling height 8 .........................--1----------------- ......... ............ ......... ...... Wall U--val ue, :R-val ue Q.091 ill .......... Floor U-value R-value 0.2 5 ........... .................. .......... ...... ........ teifing V-va[ue I R-value 0.0-5 1 19 Window U-value ................ ............. ....... ........... ------- Window SH-G.F �:O.85, ............ .......... .................- ........... .......... .............- ..................... ............. Moisture grains 0.85 ------------------------------- Duct loss -0/0. ............ ............... ............. .......- ...................... ........... ........... Duct gain % 10 .......... ...... ............ Cooling infiftraction (ACH), .....................- ............. ................. .................... Heating infiltration (ACH) 0.8 .......... ...... Winter ventilation .................... ............. ........ ......... ..... Summer ventilation 0 ;;Desiqn Conditions Outdoor Heating Cooling ........................ ........... ....... .......... Dry bulb ('F) � 32 93 ............. .............................. ..................... ...............................- Daily range M .......... ............ ....................................... ------ ------------------------ Relative humidity ............ .......... ............... ............ ........... .............. .......... Moisture difference 53 ............................................... .......................................- ..................... ................ .............. .......................... Indoor Heating Cooling ......................... Indoor temperature (OF), 70 75 ............................ ............... ................................... ..................... Design temperature difference('F) 38 18 .............1-......................-..-..................... ............................ ................................. ............. ............................................................................- ..........- Heating Loads Area Btuh % of load .......... Wall 1860 �9.7 Floor 5700 29.9 ..................... .......................... ...............- ,Ceiling 1511 Windows 5168 27.1 ............. .......... ........ ......... Infiltration 3110. 116.3 ......................... ------------------ ......................... System Efficiency Loss 1735 9.1 .......... Total: 19083 ............ ................. Heating Loads 19,083 BTU/hr Ceiling System Efficiency Loss Floor K Wall Infiltration Windows 'A� Cooling Loads M,'u'M .'Ev"Mmt' -�E Latent infiltration: SHR a.89 tapac,ity of 15��SHR 2.05 Ton� ............. Cooling Loads 20,783 BTU/hr Sensible People Load Latent People Load Ceiling Internal Wall Sensible Infiltration:, System Efficiencl, Windows Latent Infiltration Adequ te Exposure Diversity AED Graph 20000 15000 M 10000 5000 0 8am 9am loam Ilam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm Hourly Loads Average ACCA Manual S System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F Summer Wet Bulb 7110F ............................ .............. ............. Summer Indoor 75`F ............. ............... -1-1--...... ........................... Summer Design Grains 50% ......... ........... ...................... ........... .............. ........... Winter Outdoor 320F .......... Winter Indoor. 70017 .................................... ...... .......... .................. Sensible Cooling 18,427 Btuh ............. .................. ........... ........... ........ Latent Coollng 2,356 Btuh. ,:, ............. ............ .................................... Required Cooling Airflow 838 CFM ............ ............ ................. Sensible Heating Btuh- ---------- ...... ................. ................. ............. Required Heaing Airflow 248 C.FM ................ .....................................- ............ ......... .............................................. All calculations are based upon approved hvac industry standards and procedures,and comply with alliocal, state and federal code requirements.All,computed results are Estimates.Product provided by Energy Design Systems and Idea Tree